Magnetic resonance imaging of hyaline cartilage defects at 1.5T and 3.0T:: comparison of medium T2-weighted fast spin echo, T1-weighted two-dimensional and three-dimensional gradient echo pulse sequences

被引:50
作者
Fischbach, F
Bruhn, H
Unterhauser, F
Ricke, J
Wieners, G
Felix, R
Weiler, A
Schröder, RJ
机构
[1] Humboldt Univ, Dept Radiol, Charite, Sch Med, D-13353 Berlin, Germany
[2] Humboldt Univ, Dept Traumat & Reconstruct Surg, Charite, Sch Med, D-13353 Berlin, Germany
关键词
cartilage; chondromalacia; high field MRI;
D O I
10.1080/02841850510012625
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Purpose: To evaluate and compare the diagnostic accuracy of appropriate magnetic resonance (MR) sequences in the detection of cartilage lesions at 1.5T and 3.0T. Material and Methods: Twelve chondral defects of varying depths, widths, and locations were created in the retropatellar hyaline cartilage in six sheep cadaver limbs. Axial images employing three fat-suppressed imaging sequences - (1) a T2-weighted fast spin-echo (FSE) sequence, (2) a two-dimensional (213) and (3) three-dimensional (313) gradient-echo (GE) sequence at 1.5T and 3.0T using an extremity quadrature coil - were evaluated by three experienced radiologists. Statistical analysis of the results consisted of receiver operating characteristics (ROC) and significant testing using the bivariate chi-square test. In addition, signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were evaluated with significance testing using the Wilcoxon test. Results: The 3D GE sequence compared favorably with other sequences at 3.0T and 1.5T (Az=0.88 at 3.0T and Az=0.85 at 1.5T) missing only one small grade 2 lesion. 2D GE imaging was inferior to 3D imaging at both field strengths (P<0.05) in general. However, compared to 1.5T, lesion detectability was improved at the higher magnetic field of 3.0T (Az=0.81 and 0.73 at 3.0T and 1.5T, respectively). FSE images showed significantly inferior sensitivity and less anatomical detail compared to the GE sequences at both field strengths (Az=0.64 and 0.72 at 3.0T and 1.5T, respectively; P<0.05). However, compared to 1.5T, lesion detectability SNR and CNR values were superior in all sequences tested at 3.0T. Conclusion: MRI at 3.0T improves SNR and CNR significantly in the most common sequences for cartilage MRI, resulting in an improvement in chondral lesion detection. GE imaging therefore allows resolution to be increased in an acceptable time manner for patient comfort, and the 3D GE fat-suppressed sequence at 3.0T appears to be best suited for cartilage imaging in a clinical setting.
引用
收藏
页码:67 / 73
页数:7
相关论文
共 17 条
[1]
Accuracy of T2-weighted fast spin-echo MR imaging with fat saturation in detecting cartilage defects in the knee: Comparison with arthroscopy in 130 patients [J].
Bredella, MA ;
Tirman, PFJ ;
Peterfy, CG ;
Zarlingo, M ;
Feller, JF ;
Bost, FW ;
Belzer, JP ;
Wischer, TK ;
Genant, HK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1073-1080
[2]
KNEE HYALINE CARTILAGE EVALUATED WITH MR IMAGING - A CADAVERIC STUDY INVOLVING MULTIPLE IMAGING SEQUENCES AND INTRAARTICULAR INJECTION OF GADOLINIUM AND SALINE SOLUTION [J].
CHANDNANI, VP ;
HO, C ;
CHU, P ;
TRUDELL, D ;
RESNICK, D .
RADIOLOGY, 1991, 178 (02) :557-561
[3]
Chen F S, 1997, Am J Orthop (Belle Mead NJ), V26, P396
[4]
MR imaging of articular cartilage [J].
Disler, DG ;
Recht, MP ;
McCauley, TR .
SKELETAL RADIOLOGY, 2000, 29 (07) :367-377
[5]
Fat-suppressed three-dimensional spoiled gradient-echo MR imaging of hyaline cartilage defects in the knee: Comparison with standard MR imaging and arthroscopy [J].
Disler, DG ;
McCauley, TR ;
Kelman, CG ;
Fuchs, MD ;
Ratner, LM ;
Wirth, CR ;
Hospodar, PP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) :127-132
[6]
Hyaline cartilage: Truncation artifact as a cause of trilaminar appearance with fat-suppressed three-dimensional spoiled gradient-recalled sequences [J].
Erickson, SJ ;
Waldschmidt, JG ;
Czervionke, LF ;
Prost, RW .
RADIOLOGY, 1996, 201 (01) :260-264
[7]
MR imaging truncation artifacts can create a false laminar appearance in cartilage [J].
Frank, LR ;
Brossmann, J ;
Buxton, RB ;
Resnick, D .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (02) :547-554
[8]
CHONDROPROTECTION, MYTH OR REALITY - AN EXPERIMENTAL APPROACH [J].
GHOSH, P ;
WELLS, C ;
SMITH, M ;
HUTADILOK, N .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 1990, 19 (04) :3-9
[9]
Investigation of laminar appearance of articular cartilage by means of magnetic resonance microscopy [J].
Mlynarik, V ;
Degrassi, A ;
Toffanin, R ;
Vittur, F ;
Cova, M ;
PozziMucelli, RS .
MAGNETIC RESONANCE IMAGING, 1996, 14 (04) :435-442
[10]
MR Imaging and T2 mapping of femoral cartilage: In vivo determination of the magic angle efect. [J].
Mosher, TJ ;
Smith, H ;
Dardzinski, BJ ;
Schmithorst, VJ ;
Smith, MB .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 177 (03) :665-669