Constant-distance mode scanning electrochemical microscopy (SECM) - Part I: Adaptation of a non-optical shear-force-based positioning mode for SECM tips

被引:145
作者
Katemann, BB [1 ]
Schulte, A [1 ]
Schuhmann, W [1 ]
机构
[1] Ruhr Univ Bochum, D-44780 Bochum, Germany
关键词
constant-distance mode; electrochemistry; microelectrodes; scanning electrochemical microscopy; scanning probe microscopy; shear forces;
D O I
10.1002/chem.200204267
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A non-optical shear-force-based detection scheme for accurately controlling the tip-to-sample distance in scanning electrochemical microscopy (SECM) is presented. With this approach, the detection of the shear force is accomplished by mechanically attaching a set of two piezoelectric plates to the scanning probe. One of the plates is used to excite the SECM tip causing it to resonate, and the other acts as a piezoelectric detector of the amplitude of the tip oscillation. Increasing shear forces in close proximity to the sample surface lead to a damping of the vibration for amplitude and a phase shift, effects that are registered by connecting the detecting piezoelectric plate to a dual-phase analogue lock-in amplifier. The shear force and hence distance-dependent signal of the lock-in amplifier is used to establish an efficient, computer-controlled closed feedback loop enabling SECM imaging in a constant-distance mode of operation. The details of the SECM setup with an integrated piezoelectric shear-force distance control are described, and approach curves are shown. The performance of the constant-distance mode SECM with a non-optical detection of shear forces is illustrated by imaging simultaneously the topography and conductivity of an array of Pt-band microelectrodes.
引用
收藏
页码:2025 / 2033
页数:9
相关论文
共 79 条
[1]   Impedance feedback control for scanning electrochemical microscopy [J].
Alpuche-Aviles, MA ;
Wipf, DO .
ANALYTICAL CHEMISTRY, 2001, 73 (20) :4873-4881
[2]   POLYMER-FILMS ON ELECTRODES .26. STUDY OF ION-TRANSPORT AND ELECTRON-TRANSFER AT POLYPYRROLE FILMS BY SCANNING ELECTROCHEMICAL MICROSCOPY [J].
ARCA, M ;
MIRKIN, MV ;
BARD, AJ .
JOURNAL OF PHYSICAL CHEMISTRY, 1995, 99 (14) :5040-5050
[3]  
BALLESTEROSKATE.B, 2002, ELECTROANAL, V14, P22
[4]  
Bard A.J., 2001, Scanning Electrochemical Microscopy
[5]   SCANNING ELECTROCHEMICAL MICROSCOPY - THEORY AND APPLICATION OF THE TRANSIENT (CHRONOAMPEROMETRIC) SECM RESPONSE [J].
BARD, AJ ;
DENAULT, G ;
FRIESNER, RA ;
DORNBLASER, BC ;
TUCKERMAN, LS .
ANALYTICAL CHEMISTRY, 1991, 63 (13) :1282-1288
[6]   SCANNING ELECTROCHEMICAL MICROSCOPY - INTRODUCTION AND PRINCIPLES [J].
BARD, AJ ;
FAN, FRF ;
KWAK, J ;
LEV, O .
ANALYTICAL CHEMISTRY, 1989, 61 (02) :132-138
[7]   CHEMICAL IMAGING OF SURFACES WITH THE SCANNING ELECTROCHEMICAL MICROSCOPE [J].
BARD, AJ ;
FAN, FRF ;
PIERCE, DT ;
UNWIN, PR ;
WIPF, DO ;
ZHOU, FM .
SCIENCE, 1991, 254 (5028) :68-74
[8]   Scanning electrochemistry microscopy (SECM) in the study of electron transfer kinetics at liquid/liquid interfaces: Beyond the constant composition approximation [J].
Barker, AL ;
Unwin, PR ;
Amemiya, S ;
Zhou, JF ;
Bard, AJ .
JOURNAL OF PHYSICAL CHEMISTRY B, 1999, 103 (34) :7260-7269
[9]   Scanning electrochemical microscopy: beyond the solid/liquid interface [J].
Barker, AL ;
Gonsalves, M ;
Macpherson, JV ;
Slevin, CJ ;
Unwin, PR .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :223-240
[10]   Scanning electrochemical microscopy at the surface of bone-resorbing osteoclasts: Evidence for steady-state disposal and intracellular functional compartmentalization of calcium [J].
Berger, CEM ;
Rathod, H ;
Gillespie, JI ;
Horrocks, BR ;
Datta, HK .
JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 (11) :2092-2102