Constant-distance mode scanning electrochemical microscopy (SECM) - Part I: Adaptation of a non-optical shear-force-based positioning mode for SECM tips

被引:145
作者
Katemann, BB [1 ]
Schulte, A [1 ]
Schuhmann, W [1 ]
机构
[1] Ruhr Univ Bochum, D-44780 Bochum, Germany
关键词
constant-distance mode; electrochemistry; microelectrodes; scanning electrochemical microscopy; scanning probe microscopy; shear forces;
D O I
10.1002/chem.200204267
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A non-optical shear-force-based detection scheme for accurately controlling the tip-to-sample distance in scanning electrochemical microscopy (SECM) is presented. With this approach, the detection of the shear force is accomplished by mechanically attaching a set of two piezoelectric plates to the scanning probe. One of the plates is used to excite the SECM tip causing it to resonate, and the other acts as a piezoelectric detector of the amplitude of the tip oscillation. Increasing shear forces in close proximity to the sample surface lead to a damping of the vibration for amplitude and a phase shift, effects that are registered by connecting the detecting piezoelectric plate to a dual-phase analogue lock-in amplifier. The shear force and hence distance-dependent signal of the lock-in amplifier is used to establish an efficient, computer-controlled closed feedback loop enabling SECM imaging in a constant-distance mode of operation. The details of the SECM setup with an integrated piezoelectric shear-force distance control are described, and approach curves are shown. The performance of the constant-distance mode SECM with a non-optical detection of shear forces is illustrated by imaging simultaneously the topography and conductivity of an array of Pt-band microelectrodes.
引用
收藏
页码:2025 / 2033
页数:9
相关论文
共 79 条
[61]   Monitoring activity of living cells entrapped in a membrane-sealed microcapillary with scanning electrochemical microscopy [J].
Skiku, H ;
Shiraishi, T ;
Ohya, H ;
Matsue, T ;
Abe, H ;
Hoshi, H ;
Kobayashi, M .
ELECTROCHEMISTRY, 2000, 68 (11) :890-892
[62]   Localized visualization of chemical cross-talk in microsensor arrays by using scanning electrochemical microscopy [J].
Strike, DJ ;
Hengstenberg, A ;
Quinto, M ;
Kurzawa, C ;
Koudelka-Hep, M ;
Schuhmann, W .
MIKROCHIMICA ACTA, 1999, 131 (1-2) :47-55
[63]   Fabrication of nanometer-sized electrodes and tips for scanning electrochemical microscopy [J].
Sun, P ;
Zhang, ZQ ;
Guo, JD ;
Shao, YH .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :5346-5351
[64]   Scanning electrochemical microscopy. 38. Application of SECM to the study of charge transfer through bilayer lipid membranes [J].
Tsionsky, M ;
Zhou, JF ;
Amemiya, S ;
Fan, FRF ;
Bard, AJ ;
Dryfe, RAW .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4300-4305
[65]   Photosynthetic electron transport in single guard cells as measured by scanning electrochemical microscopy [J].
Tsionsky, M ;
Cardon, ZG ;
Bard, AJ ;
Jackson, RB .
PLANT PHYSIOLOGY, 1997, 113 (03) :895-901
[66]   Patterning and characterization of surfaces with organic and biological molecules by the scanning electrochemical microscope [J].
Turyan, I ;
Matsue, T ;
Mandler, D .
ANALYTICAL CHEMISTRY, 2000, 72 (15) :3431-3435
[67]   Microstructuring of solid-supported lipid layers using SAM pattern generation by scanning electrochemical microscopy and the chemical lens [J].
Ufheil, J ;
Boldt, FM ;
Börsch, M ;
Borgwarth, K ;
Heinze, J .
BIOELECTROCHEMISTRY, 2000, 52 (01) :103-110
[68]   Scanning electrochemical microscopy of membrane transport in the reverse imaging mode [J].
Uitto, OD ;
White, HS .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :533-539
[69]   Patterns of functional proteins formed by local electrochemical desorption of self-assembled monolayers [J].
Wilhelm, T ;
Wittstock, G .
ELECTROCHIMICA ACTA, 2001, 47 (1-2) :275-281
[70]   INITIATION AND STUDY OF LOCALIZED CORROSION BY SCANNING ELECTROCHEMICAL MICROSCOPY [J].
WIPF, DO .