Calibration of the well-type germanium gamma-ray detector employing two gamma-ray spectra

被引:18
作者
Blaauw, M [1 ]
机构
[1] Delft Univ Technol, Interfac Reactor Inst, NL-2629 JB Delft, Netherlands
关键词
WELL detectors; gamma-ray spectrometry; calibration; true coincidence summing; INAA-nuclides;
D O I
10.1016/S0168-9002(98)01158-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 [仪器科学与技术]; 080401 [精密仪器及机械]; 081102 [检测技术与自动化装置];
摘要
Since 1992, a method has been under development at IRI to characterise a well-type gamma-ray detector by determination of a peak efficiency and a peak-to-total efficiency curve through measurement of a radionuclide emitting coincident photons, and to compute radionuclide specific counting efficiencies from those curves for "'real" peaks as well as for "sum" peaks. Recent improvements to this method have indicated that now, a well-type can be as easy to calibrate and operate as a coaxial detector, once the software is in place. In this paper, the improved calibration method will be described and examples of results given. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:146 / 153
页数:8
相关论文
共 10 条
[2]
The IRI gamma-ray catalogue for INAA [J].
Blaauw, M .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (02) :245-247
[3]
IAEA gamma-ray spectra for testing of spectrum analysis software [J].
Blaauw, M ;
Fernandez, VO ;
Westmeier, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 387 (03) :410-415
[4]
Browne E., 1986, Table of Radioactive Isotopes
[5]
SPECTRUM INTERPRETATION PROBLEMS WITH WELL-TYPE GE(LI) DETECTORS DUE TO SELF-ABSORPTION VARIATIONS [J].
DEBRUIN, M ;
KORTHOVEN, PJM ;
BODE, P .
NUCLEAR INSTRUMENTS & METHODS, 1979, 159 (2-3) :301-303
[6]
DECORTE F, 1987, THESIS RIJKSUNIVERSI
[7]
Geometry effects in well-type Ge-detectors due to the introduction of high-Z linings [J].
Gelsema, SJ ;
Blaauw, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 368 (02) :410-415
[9]
CALCULATION OF THE ABSOLUTE PEAK EFFICIENCY OF GAMMA-RAY DETECTORS FOR DIFFERENT COUNTING GEOMETRIES [J].
MOENS, L ;
DEDONDER, J ;
LIN, X ;
DECORTE, F ;
DEWISPELAERE, A ;
SIMONITS, A ;
HOSTE, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 187 (2-3) :451-472
[10]
A pulse generator simulating Ge-detector signals for dead-time and pile-up correction in gamma-ray spectrometry in INAA without distortion of the detector spectrum [J].
Then, SS ;
Geurink, FDP ;
Bode, P ;
Lindstrom, RM .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (02) :249-252