Locomotor adaptation to a powered ankle-foot orthosis depends on control method

被引:95
作者
Cain, Stephen M. [1 ,4 ]
Gordon, Keith E. [2 ,4 ]
Ferris, Daniel P. [1 ,2 ,3 ,4 ]
机构
[1] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Div Kinesiol, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Phys Med & Rehabil, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Human Neuromech Lab, Ann Arbor, MI 48109 USA
关键词
D O I
10.1186/1743-0003-4-48
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: We studied human locomotor adaptation to powered ankle-foot orthoses with the intent of identifying differences between two different orthosis control methods. The first orthosis control method used a footswitch to provide bang-bang control ( a kinematic control) and the second orthosis control method used a proportional myoelectric signal from the soleus ( a physiological control). Both controllers activated an artificial pneumatic muscle providing plantar flexion torque. Methods: Subjects walked on a treadmill for two thirty-minute sessions spaced three days apart under either footswitch control (n = 6) or myoelectric control ( n = 6). We recorded lower limb electromyography (EMG), joint kinematics, and orthosis kinetics. We compared stance phase EMG amplitudes, correlation of joint angle patterns, and mechanical work performed by the powered orthosis between the two controllers over time. Results: During steady state at the end of the second session, subjects using proportional myoelectric control had much lower soleus and gastrocnemius activation than the subjects using footswitch control. The substantial decrease in triceps surae recruitment allowed the proportional myoelectric control subjects to walk with ankle kinematics close to normal and reduce negative work performed by the orthosis. The footswitch control subjects walked with substantially perturbed ankle kinematics and performed more negative work with the orthosis. Conclusion: These results provide evidence that the choice of orthosis control method can greatly alter how humans adapt to powered orthosis assistance during walking. Specifically, proportional myoelectric control results in larger reductions in muscle activation and gait kinematics more similar to normal compared to footswitch control.
引用
收藏
页数:13
相关论文
共 25 条
[1]  
AARON SL, 1976, AM J PHYS MED REHAB, V55, P1
[2]   Adaptive control of a variable-impedance ankle-foot orthosis to assist drop-foot gait [J].
Blaya, JA ;
Herr, H .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2004, 12 (01) :24-31
[3]   The effects of adding mass to the legs on the energetics and biomechanics of walking [J].
Browning, Raymond C. ;
Modica, Jesse R. ;
Kram, Rodger ;
Goswami, Ambarish .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (03) :515-525
[4]  
Ferris Daniel P, 2005, Top Spinal Cord Inj Rehabil, V11, P34
[5]   An improved powered ankle-foot orthosis using proportional myoelectric control [J].
Ferris, Daniel P. ;
Gordon, Keith E. ;
Sawicki, Gregory S. ;
Peethambaran, Arnmanath .
GAIT & POSTURE, 2006, 23 (04) :425-428
[6]   An ankle-foot orthosis powered by artificial pneumatic muscles [J].
Ferris, DP ;
Czerniecki, JM ;
Hannaford, B .
JOURNAL OF APPLIED BIOMECHANICS, 2005, 21 (02) :189-197
[7]   Control and system identification for the Berkeley lower extremity exoskeleton (BLEEX) [J].
Ghan, Justin ;
Steger, Ryan ;
Kazerooni, H. .
ADVANCED ROBOTICS, 2006, 20 (09) :989-1014
[8]   Learning to walk with a robotic ankle exoskeleton [J].
Gordon, Keith E. ;
Ferris, Daniel P. .
JOURNAL OF BIOMECHANICS, 2007, 40 (12) :2636-2644
[9]   Mechanical performance of artificial pneumatic muscles to power an ankle-foot orthosis [J].
Gordon, Keith E. ;
Sawicki, Gregory S. ;
Ferris, Daniel P. .
JOURNAL OF BIOMECHANICS, 2006, 39 (10) :1832-1841
[10]  
Hayashi T., 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, P3063