Transcatheter Heart Valve With Variable Geometric Configuration: In Vitro Evaluation

被引:21
作者
Young, Ernest [1 ,2 ]
Chen, Ji-Feng [1 ]
Dong, Owen [3 ]
Gao, Shengqiang [1 ]
Massiello, Alex [1 ]
Fukamachi, Kiyotaka [1 ]
机构
[1] Cleveland Clin, Dept Biomed Engn, Lerner Res Inst, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
[3] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14853 USA
关键词
Heart valveu; Transapicalu; Percutaneous; Aortic valve calcificationu; In vitro studies; CALCIFIC AORTIC-STENOSIS; EXPANDING COREVALVE PROSTHESIS; MULTISLICE COMPUTED-TOMOGRAPHY; HIGH-RISK PATIENTS; IMPLANTATION; REPLACEMENT; EXPERIENCE; SUCCESS; SYSTEM;
D O I
10.1111/j.1525-1594.2011.01331.x
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Clinically, the current transcatheter aortic valve (TAV) technology has shown a propensity for paravalvular leakage; studies have correlated this flaw to increased calcification at the implantation site and with nonideal geometry of the stented valve. The present study evaluated the hydrodynamics of different geometric configurations, in particular the intravalvular considerations. Three TAV devices were made to create a representative, size 26 mm TAV. Hydrodynamics were assessed using a pulse duplicator. The geometries tested were composed of the nominal, elliptical, triangular, and undersized shapes; along with half-constriction, a conformation in which only a portion of the stent was constrained. The TAVs were assessed for transvalvular pressure gradient (TVG), effective orifice area (EOA), and regurgitant fraction. The nominal-sized shape posed a larger TVG (6.2 +/- 0.3 mm Hg) than other configurations (P < 0.001) except the undersized valves. EOA of the nominal sized TAV (1.7 +/- 0.1 cm2) was smaller than that of the triangular and half-elliptical versions (P < 0.001). The half- and full-undersized geometries had EOAs smaller than the nominal type (P < 0.001). Nominal shape had smaller regurgitation (6.7 +/- 1.4%) than all configurations (P < 0.001) except for the half-undersized (4.0 +/- 0.7, P < 0.001) with no statistically significant difference from the full-undersized (6.8 +/- 1.3, P = 0.724). The testing of variable geometries showed significant differences from the nominal geometry with respect to TVG, EOA, and regurgitant fraction. In particular, many of these nonideal configurations demonstrated an increased intravalvular regurgitation.
引用
收藏
页码:1151 / 1159
页数:9
相关论文
共 27 条
[1]
Immediate and Long-Term Echocardiographic Findings after Transcatheter Aortic Valve Implantation for the Treatment of Aortic Stenosis: The Cribier-Edwards/Edwards-Sapien Valve Experience [J].
Bauer, Fabrice ;
Lemercier, Mathieu ;
Zajarias, Alan ;
Tron, Christophe ;
Eltchaninoff, Helene ;
Cribier, Alain .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (04) :370-376
[2]
Assessment of aortic annulus dimensions for Edwards SAPIEN Transapical Heart Valve implantation by computed tomography: calculating average diameter using a virtual ring method [J].
Blanke, Philipp ;
Siepe, Matthias ;
Reinoehl, Jochen ;
Zehender, Manfred ;
Beyersdorf, Friedhelm ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (06) :750-758
[3]
Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[4]
Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[5]
Treatment of calcific aortic stenosis with the percutaneous heart valve - Mid-term follow-up from the initial feasibility studies: The French experience [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Nercolini, D ;
Tapiero, S ;
Litzler, PY ;
Bessou, JP ;
Babaliaros, V .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (06) :1214-1223
[6]
Transcatheter aortic valve implantation: role of multi-detector row computed tomography to evaluate prosthesis positioning and deployment in relation to valve function [J].
Delgado, Victoria ;
Ng, Arnold C. T. ;
van de Veire, Nico R. ;
van der Kley, Frank ;
Schuijf, Joanne D. ;
Tops, Laurens F. ;
de Weger, Arend ;
Tavilla, Giuseppe ;
de Roos, Albert ;
Kroft, Lucia J. ;
Schalij, Martin J. ;
Bax, Jeroen J. .
EUROPEAN HEART JOURNAL, 2010, 31 (09) :1114-1123
[7]
FDA, 1985, TEST PROT INT COMP P
[8]
First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve [J].
Grube, E ;
Laborde, JC ;
Zickmann, B ;
Gerckens, U ;
Felderhoff, T ;
Sauren, B ;
Bootsveld, A ;
Buellesfeld, L ;
Iversen, S .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) :465-469
[9]
Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76
[10]
Percutaneous implantation of the CoreValve self-expanding valve prosthesis in high-risk patients with aortic valve disease - The Siegburg First-in-Man Study [J].
Grube, Eberhard ;
Laborde, Jean C. ;
Gerckens, Ulrich ;
Felderhoff, Thomas ;
Sauren, Barthel ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
Menichelli, Maurizio ;
Schmidt, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Stone, Gregg W. .
CIRCULATION, 2006, 114 (15) :1616-1624