Clinical use of intracardiac impedance: Current applications and future perspectives

被引:16
作者
Arthur, W
Kaye, GC
机构
[1] Castle Hill Hospital, East Yorkshire
[2] Castle Hill Hospital, Cottingham, East Yorkshire, Castle Road
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2001年 / 24卷 / 04期
关键词
intracardiac; impedance; conductance catheter; myocardial contractility;
D O I
10.1046/j.1460-9592.2001.00500.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For over 40 years the measurement of intracardiac impedance has been proposed as a method of assessing the contractile state of the heart muscle. This technique requires the positioning of one or more intracavitary electrodes and the generation of an electric field from an alternating current source. Variations in the calculated impedance signal reflect changes in the ventricular blood pool volume adjacent to the electrodes. Intracardiac impedance measurement has been successfully developed as a research tool to assess myocardial contractility, and from this, clinical uses have evolved. Commercial rate responsive pacing systems use intracardiac impedance to assess the inotropic state of the heart. Further development of this technology might allo cr hemodynamic discrimination of cardiac arrhythmias.
引用
收藏
页码:500 / 506
页数:7
相关论文
共 45 条
[1]   INITIAL CLINICAL-EXPERIENCE WITH A NEW DUAL SENSOR SSIR PACEMAKER CONTROLLED BY BODY ACTIVITY AND MINUTE VENTILATION [J].
ALT, E ;
COMBS, W ;
FOTUHI, P ;
BAMBL, E ;
WAHLSTRAND, J ;
WILLHAUS, R .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08) :1487-1495
[2]   SIMULTANEOUS CONDUCTANCE CATHETER AND DIMENSION ASSESSMENT OF LEFT-VENTRICLE VOLUME IN THE INTACT ANIMAL [J].
APPLEGATE, RJ ;
CHENG, CP ;
LITTLE, WC .
CIRCULATION, 1990, 81 (02) :638-648
[3]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[4]   CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[5]   FAILURE OF THE AUTOMATIC IMPLANTABLE DEFIBRILLATOR TO DETECT VENTRICULAR-FIBRILLATION [J].
BARDY, GH ;
IVEY, TD ;
STEWART, R ;
GRAHAM, EL ;
GREENE, HL .
AMERICAN JOURNAL OF CARDIOLOGY, 1986, 58 (11) :1107-1108
[6]  
BEAN J, 1982, CIRCULATION, V66, P277
[7]  
BINGGELI C, 1999, PACE 2, V22, P899
[8]  
BINGGELI C, 1999, PACE 2, V22, pA11
[9]  
BONGIORNI MG, 1999, PACE 2, V22, pA10
[10]  
BONGIORNI MG, 1997, PACE, P525