Expanded instrument comparison of amplicon DNA melting analysis for mutation scanning and genotyping

被引:140
作者
Herrmann, Mark G.
Durtschi, Jacob D.
Wittwer, Carl T.
Voelkerding, Karl V.
机构
[1] ARUP, Inst Clin & Expt Pathol, Salt Lake City, UT USA
[2] Univ Utah, Sch Med, Dept Pathol, Salt Lake City, UT USA
关键词
D O I
10.1373/clinchem.2007.088120
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Additional instruments have become available since instruments for DNA melting analysis of PCR products for genotyping and mutation scanning were compared. We assessed the performance of these new instruments for genotyping and scanning for mutations. Methods: A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (HBB c. 20A > T) was amplified by PCR in the presence of LCGreen Plus or SYBR Green I. Amplicons of 4 different genotypes [wild-type, homozygous, and heterozygous HBB c. 20A > T and double-heterozygote HBB c. (9C > T, 20A > T)] were melted on 7 different instruments [Applied Bio-systems 7300, Corbett Life Sciences Rotor-Gene 6500HRM, Eppendorf Mastercycler RealPlex4S, Idaho Technology LightScanner (384 well), Roche LightCycler 480 (96 and 384 well) and Stratagene Mx3005p] at a rate of 0.61 degrees C/s or when this was not possible, at 0.50 degrees C steps. We evaluated the ability of each instrument to genotype by melting temperature (T-m) and to scan for heterozygotes by curve shape. Results: The ability of most instruments to accurately genotype single-base changes by amplicon melting was limited by spatial temperature variation across the plate (SD of T-m = 0.020 to 0.264 degrees C). Other variables such as data density, signal-to-noise ratio, and melting rate also affected heterozygote scanning. Conclusions: Different instruments vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole amplicon melting analysis. Instruments specifically designed for high-resolution melting, however, displayed the least variation, suggesting better genotyping accuracy and scanning sensitivity and specificity. (c) 2007 American Association for Clinical Chemistry.
引用
收藏
页码:1544 / 1548
页数:5
相关论文
共 15 条
[1]   Distinguishing different DNA heterozygotes by high-resolution melting [J].
Graham, R ;
Liew, M ;
Meadows, C ;
Lyon, E ;
Wittwer, CT .
CLINICAL CHEMISTRY, 2005, 51 (07) :1295-1298
[2]   Amplicon melting analysis with labeled primers: A closed-tube method for differentiating homozygotes and heterozygotes [J].
Gundry, CN ;
Vandersteen, JG ;
Reed, GH ;
Pryor, RJ ;
Chen, J ;
Wittwer, CT .
CLINICAL CHEMISTRY, 2003, 49 (03) :396-406
[3]   Instrument comparison for heterozygote scanning of single and double heterozygotes:: A correction and extension of Herrmann et al., Clin Chem 2006;52:494-503 [J].
Herrmann, Mark G. ;
Durtschi, Jacob D. ;
Bromley, L. Kathryn ;
Wittwer, Carl T. ;
Voelkerding, Karl V. .
CLINICAL CHEMISTRY, 2007, 53 (01) :150-152
[4]   Amplicon DNA melting analysis for mutation scanning and genotyping: Cross-platform comparison of instruments and dyes [J].
Herrmann, MG ;
Durtschi, JD ;
Bromley, LK ;
Wittwer, CT ;
Voelkerding, KV .
CLINICAL CHEMISTRY, 2006, 52 (03) :494-503
[5]   High resolution melting analysis for the rapid and sensitive detection of mutations in clinical samples:: KRAS codon 12 and 13 mutations in non-small cell lung cancer [J].
Krypuy, Michael ;
Newnham, Genni M. ;
Thomas, David M. ;
Conron, Matthew ;
Dobrovic, Alexander .
BMC CANCER, 2006, 6 (1)
[6]  
Lay MJ, 1997, CLIN CHEM, V43, P2262
[7]   Genotyping of single-nucleotide polymorphisms by high-resolution melting of small amplicons [J].
Liew, M ;
Pryor, R ;
Palais, R ;
Meadows, C ;
Erali, M ;
Lyon, E ;
Wittwer, C .
CLINICAL CHEMISTRY, 2004, 50 (07) :1156-1164
[8]   Closed-tube SNP genotyping without labeled probes a comparison between unlabeled probe and amplicon melting [J].
Liew, Michael ;
Seipp, Michael ;
Durtschi, Jacob ;
Margraf, Rebecca L. ;
Dames, Shale ;
Erali, Maria ;
Voelkerding, Karl ;
Wittwer, Carl .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2007, 127 (03) :341-348
[9]   Molecular beacon-based temperature control and automated analyses for improved resolution of melting temperature analysis using SYBR I Green chemistry [J].
Nellaker, Christoffer ;
Wallgren, Ulf ;
Karlsson, Hakan .
CLINICAL CHEMISTRY, 2007, 53 (01) :98-103
[10]   Quantitative heteroduplex analysis for single nucleotide polymorphism genotyping [J].
Palais, RA ;
Liew, MA ;
Wittwer, CT .
ANALYTICAL BIOCHEMISTRY, 2005, 346 (01) :167-175