Dispersive liquid-liquid microextraction and spectrophotometric determination of cobalt in water samples

被引:75
作者
Gharehbaghi, Maysam [1 ]
Shemirani, Farzaneh [1 ]
Baghdadi, Majid [1 ]
机构
[1] Univ Tehran, Univ Coll Sci, Sch Analyt Chem, Tehran, Iran
关键词
dispersive liquid - liquid microextraction; cobalt; water samples; spectrophotometry;
D O I
10.1080/03067310701809128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new simple and rapid dispersive liquid-liquid microextraction has been applied to preconcentrate trace levels of cobalt as a prior step to its determination by spectrophotometric detection. In this method a small amount of chloroform as the extraction solvent was dissolved in pure ethanol as the disperser solvent, then the binary solution was rapidly injected by a syringe into the water sample containing cobalt ions complexed by 1-(2-pyridylazo)-2-naphthol (PAN). This forms a cloudy solution. The cloudy state was the result of chloroform fine droplets formation, which has been dispersed in bulk aqueous sample. Therefore, Co-PAN complex was extracted into the fine chloroform droplets. After centrifugation (2 min at 5000 rpm) these droplets were sedimented at the bottom of conical test tube (about 100 mu L) and then the whole of complex enriched extracted phase was determined by a spectrophotometer at 577 nm. Complex formation and extraction are usually affected by some parameters, such as the types and volumes of extraction solvent and disperser solvent, salt effect, pH and the concentration of chelating agent, which have been optimised for the presented method. Under optimum conditions, the enhancement factor (as the ratio of slope of preconcentrated sample to that obtained without preconcentration) of 125 was obtained from 50 mL of water sample, and the limit of detection (LOD) of the method was 0.5 mu g L(-1)and the relative standard deviation (RSD, n = 5) for 50 mu g L-1 of cobalt was 2.5%. The method was applied to the determination of cobalt in tap and river water samples.
引用
收藏
页码:513 / 523
页数:11
相关论文
共 26 条
[1]  
Agency for Toxic Substances and Disease Registry (ATSDR), 2004, TOX PROF COB
[2]   Cobalt ultra-trace on-line preconcentration and determination using a PTFE turnings packed column and electrothermal atomic absorption spectrometry. Applications in natural waters and biological samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (10) :1330-1334
[3]   Development of an on-line solvent extraction system for electrothermal atomic absorption spectrometry utilizing a new gravitational phase separator. Determination of cadmium in natural waters and urine samples [J].
Anthemidis, AN ;
Zachariadis, GA ;
Stratis, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (11) :1400-1403
[4]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[5]   A rapid Chelex column method for the determination of metal speciation in natural waters [J].
Bowles, KC ;
Apte, SC ;
Batley, GE ;
Hales, LT ;
Rogers, NJ .
ANALYTICA CHIMICA ACTA, 2006, 558 (1-2) :237-245
[6]   Separation and determination of trace amounts of zinc, lead, cadmium and mercury in tap and Qaroun lake water using polyurethane foam functionalized with 4-hydroxytoluene and 4-hydroxyacetophenone [J].
Burham, N. ;
Abdel-Azeem, S. M. ;
El-Shahat, M. F. .
ANALYTICA CHIMICA ACTA, 2006, 579 (02) :193-201
[7]   A new method of microvolume back-extraction procedure for enrichment of Pb and Cd and determination by flame atomic absorption spectrometry [J].
Carasek, E ;
Tonjes, JW ;
Scharf, M .
TALANTA, 2002, 56 (01) :185-191
[8]   Determination of cobalt and nickel in water samples by flame atomic absorption spectrometry after cloud point extraction [J].
Chen, JR ;
Teo, KC .
ANALYTICA CHIMICA ACTA, 2001, 434 (02) :325-330
[9]   Flotation separation of cobalt and copper from fresh waters and their determination by electrothermal atomic absorption spectrometry [J].
Cundeva, K ;
Stafilov, T ;
Pavlovska, G .
MICROCHEMICAL JOURNAL, 2000, 65 (02) :165-175
[10]   Determination of Cd in biological samples by flame AAS following on-line preconcentration by complexation with 0,0-diethyldithiophosphate and solid phase extraction with Amberlite XAD-4 [J].
dos Santos, EJ ;
Herrmann, AB ;
Ribeiro, AS ;
Curtius, AJ .
TALANTA, 2005, 65 (02) :593-597