Comparison of a cathode-ray-tube and film for display of computed radiographic images

被引:17
作者
Cook, LT [1 ]
Cox, GG
Insana, MF
McFadden, MA
Hall, TJ
Gaborski, RS
Lure, FYM
机构
[1] Univ Kansas, Med Ctr, Dept Radiol, Kansas City, KS 66160 USA
[2] Eastman Kodak Co, Div Hlth Sci, Adv Imaging Res Lab, Rochester, NY 14650 USA
关键词
contrast-detail analysis; cathode-ray-tube monitor; luminance;
D O I
10.1118/1.598304
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The goal of the study was to compare a cathode-ray-tube (CRT) digital display with film by using task-dependent image quality assessment methods. Contrast-detail analysis was utilized. Human observers performed a simple detection task, specifically, detecting a pillbox target in a uniform Poisson field, using either film or a digital display that employed a CRT monitor. Observers performed equally well on both film and CRT when the window settings of the digital display were established subjectively by a radiologist. Changing the window settings of the digital display to match the average background luminance of a film-illuminator combination decreased the luminance contrast of the targets and observer performance was reduced, though these effects were probably not linked. The "gold standard" film had lower luminance contrast than the CRT displayed images, yet observer performance was never lower for film than for the CRT. Therefore we concluded that luminance contrast was not a limiting factor for observer performance in this study. The CRT monitor changed fairly rapidly after it was calibrated. During a period of six months the gamma of the display increased from 1.82 to 2.42 and the maximum luminance decreased from 319 to 228 cd/m(2). Low luminance output demonstrated a larger percentage decrease (approximate to 85%) than high luminance output (approximate to 29%) over the same time period. These observations suggest that standard window settings should be reviewed from time to time to ensure that the display is used optimally. No special look-up table setup such as perceptual linearization was used. (C) 1998 American Association of Physicists in Medicine.
引用
收藏
页码:1132 / 1138
页数:7
相关论文
共 22 条
[1]   RECEIVER OPERATING CHARACTERISTIC ANALYSIS OF FRACTURE AND PNEUMONIA DETECTION - COMPARISON OF LASER-DIGITIZED WORKSTATION IMAGES AND CONVENTIONAL ANALOG RADIOGRAPHS [J].
ACKERMAN, SJ ;
GITLIN, JN ;
GAYLER, RW ;
FLAGLE, CD ;
BRYAN, RN .
RADIOLOGY, 1993, 186 (01) :263-268
[2]  
[Anonymous], 1983, Statistical methods
[3]   USE OF CONTRAST-DETAIL-DOSE EVALUATION OF IMAGE QUALITY IN A COMPUTED TOMOGRAPHIC SCANNER [J].
COHEN, G ;
DIBIANCA, FA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (02) :189-195
[4]   COMPARISON OF THE LOW-CONTRAST DETECTABILITY OF A SCREEN-FILM SYSTEM AND 3RD-GENERATION COMPUTED RADIOGRAPHY [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1994, 21 (05) :691-695
[5]   CONTRAST-DETAIL ANALYSIS OF IMAGE DEGRADATION DUE TO LOSSY COMPRESSION [J].
COOK, LT ;
INSANA, MF ;
MCFADDEN, MA ;
HALL, TJ ;
COX, GG .
MEDICAL PHYSICS, 1995, 22 (06) :715-721
[6]  
FLYNN M, 1995, P SOC PHOTO-OPT INS, V2431, P360, DOI 10.1117/12.207629
[7]   BASIC IMAGING PROPERTIES OF A COMPUTED RADIOGRAPHIC SYSTEM WITH PHOTOSTIMULABLE PHOSPHORS [J].
FUJITA, H ;
UEDA, K ;
MORISHITA, J ;
FUJIKAWA, T ;
OHTSUKA, A ;
SAI, T .
MEDICAL PHYSICS, 1989, 16 (01) :52-59
[8]  
Gonzalez RC, 1987, Digital Image Processing, V2nd
[9]  
GREEN D, 1988, SIGNAL DETECTION THE
[10]   RECEIVER OPERATING CHARACTERISTIC EVALUATION OF COMPUTER DISPLAY OF ADULT PORTABLE CHEST RADIOGRAPHS [J].
KRUPINSKI, EA ;
MALONEY, K ;
BESSEN, SC ;
CAPP, MP ;
GRAHAM, K ;
HUNT, R ;
LUND, P ;
OVITT, T ;
STANDEN, JR .
INVESTIGATIVE RADIOLOGY, 1994, 29 (02) :141-146