Fast multislice mapping of the myelin water fraction using multicompartment analysis of T2* decay at 3T:: A preliminary postmortem study

被引:156
作者
Du, Yiping P.
Chu, Renxin
Hwang, Dosik
Brown, Mark S.
Kleinschmidt-DeMasters, Bette K.
Singel, Debra
Simon, Jack H.
机构
[1] Univ Colorado, Hlth Sci Ctr, Dept Radiol, Aurora, CO 80010 USA
[2] Univ Colorado, Hlth Sci Ctr, Dept Pathol, Aurora, CO 80010 USA
[3] Univ Colorado, Hlth Sci Ctr, Dept Neurol, Aurora, CO 80010 USA
[4] Univ Colorado, Hlth Sci Ctr, Dept Neurosurg, Aurora, CO 80010 USA
[5] Portland VA Med Ctr, Dept Imaging, Portland, OR USA
关键词
myelin water fraction; multicompartment analysis; demyelination; multiple sclerosis; postmortem;
D O I
10.1002/mrm.21409
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative mapping of the myelin water content can provide significant insight into the pathophysiology of several white matter diseases, such as multiple sclerosis and leukoencephalopathies, and can potentially become a useful clinical tool for early diagnosis of these diseases. In this study, multicompartment analysis of T-2(*) decay (MCAT2(*)) was used for the quantitative mapping of myelin water fraction (MWF). T-2(*) decay of each voxel at multiple slice locations was acquired in fixed human brains using a multigradient-echo (MGRE) pulse sequence with alternating readout gradient polarities. Compared to prior techniques using Carr-Purcell-Meiboom-Gill (CPMG) acquisition, the MGRE acquisition approach has: 1) a very short first echo time (approximate to 2 ms) and echo-spacing (approximate to 1 ms), which allows for the acquisition of multiple sampling points during the fast decay of the myelin water signal; 2) a low RF duty cycle, which is especially important for achieving acceptable specific absorption rate (SAR) levels at high field strengths. Multicompartment analysis was then applied to the T-2(*) decay in each pixel using a 3-pool model of white matter to detect the signal arising from the myelin water, myelinated axonal water, and mixed water compartments.
引用
收藏
页码:865 / 870
页数:6
相关论文
共 18 条
[1]   Testing the three-pool white matter model adapted for use with T2 relaxometry [J].
Andrews, T ;
Lancaster, JL ;
Dodd, SJ ;
Contreras-Sesvold, C ;
Fox, PT .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) :449-454
[2]   Reduction of spectral ghost artifacts in high-resolution echo-planar spectroscopic Imaging of water and fat resonances [J].
Du, WL ;
Du, YP ;
Fan, XB ;
Zamora, MA ;
Karczmar, GS .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (06) :1113-1120
[3]   MEASUREMENT OF SIGNAL INTENSITIES IN THE PRESENCE OF NOISE IN MR IMAGES [J].
HENKELMAN, RM .
MEDICAL PHYSICS, 1985, 12 (02) :232-233
[4]   REDUCTION OF SIGNAL FLUCTUATION IN FUNCTIONAL MRI USING NAVIGATOR ECHOES [J].
HU, XP ;
KIM, SG .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (05) :495-503
[5]   Linear combination of multiecho data:: Short T2 component selection [J].
Jones, CK ;
Xiang, QS ;
Whittall, KP ;
MacKay, AL .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :495-502
[6]   Three-pool model of white matter [J].
Lancaster, JL ;
Andrews, T ;
Hardies, LJ ;
Dodd, S ;
Fox, PT .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (01) :1-10
[7]   Water content and myelin water fraction in multiple sclerosis -: A T2 relaxation study [J].
Laule, C ;
Vavasour, IM ;
Moore, GRW ;
Oger, J ;
Li, DKB ;
Paty, DW ;
MacKay, AL .
JOURNAL OF NEUROLOGY, 2004, 251 (03) :284-293
[8]   NMR POPULATION-INVERSION USING A COMPOSITE PULSE [J].
LEVITT, MH ;
FREEMAN, R .
JOURNAL OF MAGNETIC RESONANCE, 1979, 33 (02) :473-476
[9]   IN-VIVO VISUALIZATION OF MYELIN WATER IN BRAIN BY MAGNETIC-RESONANCE [J].
MACKAY, A ;
WHITTALL, K ;
ADLER, J ;
LI, D ;
PATY, D ;
GRAEB, D .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (06) :673-677
[10]   PROTON RELAXATION STUDIES OF WATER COMPARTMENTALIZATION IN A MODEL NEUROLOGICAL SYSTEM [J].
MENON, RS ;
RUSINKO, MS ;
ALLEN, PS .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) :264-274