Acceleration versus heart rate for estimating energy expenditure and speed during locomotion in animals:: Tests with an easy model species, Homo sapiens

被引:95
作者
Halsey, Lewis G. [1 ]
Shepard, Emily L. C. [3 ]
Hulston, Carl J. [2 ]
Venables, Michelle C. [2 ]
White, Craig R. [1 ]
Jeukendrup, Asker E. [2 ]
Wilson, Rory P. [3 ]
机构
[1] Univ Birmingham, Sch Biosci, Ctr Ornithol, Edgbaston B15 2TT, England
[2] Univ Birmingham, Sch Sport & Exercise Sci, Edgbaston B15 2TT, England
[3] Univ Coll Swansea, Sch Environm & Soc, Inst Environm Sustainabil, Swansea SA2 8PP, W Glam, Wales
关键词
accelerometry; energetics; heart rate; metabolic rate; oxygen consumption;
D O I
10.1016/j.zool.2007.07.011
中图分类号
Q95 [动物学];
学科分类号
071002 ;
摘要
An important element in the measurement of energy budgets of free-living animals is the estimation of energy costs during locomotion. Using humans as a particularly tractable model species, we conducted treadmill experiments to test the validity of tri-axial accelerometry loggers, designed for use with animals in the field, to estimate rate of oxygen consumption (VO2: an indirect measure of metabolic rate) and speed during locomotion. The predictive power of overall dynamic body acceleration (ODBA) obtained from loggers attached to different parts of the body was compared to that of heart rate (f(H)). When subject identity was included in the statistical analysis, ODBA was a good, though slightly poorer, predictor Of VO2 and speed during locomotion on the flat (mean of two-part regressions: R-2 = 0.91 and 0.91, from a logger placed on the neck) and VO2 during gradient walking (single regression: R-2 = 0.77 from a logger placed on the upper back) than was fH (R-2 = 0.96, 0.94, 0.86, respectively). For locomotion on the flat, ODBA was still a good predictor when subject identity was replaced by subject mass and height (morphometrics typically obtainable from animals in the field; R-2 = 0.92 and 0.89) and a slightly better overall predictor than fH (R-2 = 0.92 and 0.85). For gradient walking, ODBA predicted VO2 more accurately than before (R-2 = 0.83) and considerably better than did f(H) (R-2 = 0.77). ODBA and fH combined were the most powerful predictor Of VO2 and speed during locomotion. However, ODBA alone appears to be a good predictor and suitable for use in the field in particular, given that accelerometry traces also provide information on the timing, frequency and duration of locomotion events, and also the gait being used. (c) 2008 Elsevier GmbH. All rights reserved.
引用
收藏
页码:231 / 241
页数:11
相关论文
共 59 条
[1]   Determination of the exercise intensity that elicits maximal fat oxidation [J].
Achten, J ;
Gleeson, M ;
Jeukendrup, AE .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2002, 34 (01) :92-97
[2]  
[Anonymous], 2002, PRINCIPLES ANIMAL LO
[3]  
Bennett A.F., 1985, P173
[4]  
BEVAN RM, 1994, J EXP BIOL, V193, P119
[5]  
BLIX AS, 1974, AEROSPACE MED, V45, P1219
[6]   STUDIES IN MUSCULAR ACTIVITY. III. Dynamical changes occurring in man at work [J].
Bock, A. V. ;
Vancaulaert, C. ;
Dill, D. B. ;
Foelling, A. ;
Hurxthal, L. M. .
JOURNAL OF PHYSIOLOGY-LONDON, 1928, 66 (02) :136-161
[7]  
BOUTEN CV, 1994, MED SCI SPORT EXER, V26, P1516
[8]   Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking [J].
Bouten, CVC ;
Sauren, AAHJ ;
Verduin, M ;
Janssen, JD .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (01) :50-56
[9]   Effect of combined movement and heart rate monitor placement on physical activity estimates during treadmill locomotion and free-living [J].
Brage, S ;
Brage, N ;
Ekelund, U ;
Luan, J ;
Franks, PW ;
Froberg, K ;
Wareham, NJ .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (05) :517-524
[10]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454