Total protein is an effective loading control for cerebrospinal fluid western blots

被引:45
作者
Collins, Mahlon A. [1 ,2 ,3 ]
An, Jiyan [2 ,3 ]
Peller, Danielle [2 ,3 ]
Bowser, Robert [2 ,3 ]
机构
[1] Univ Pittsburgh, Dept Neurobiol, Pittsburgh, PA 15213 USA
[2] St Josephs Hosp, Dept Neurobiol & Neurol, Phoenix, AZ 85013 USA
[3] Barrow Neurol Inst, Phoenix, AZ 85013 USA
基金
美国国家卫生研究院;
关键词
Cerebrospinal fluid; Loading control; Total protein stain; Western blot; AMYOTROPHIC-LATERAL-SCLEROSIS; BIOMARKER DISCOVERY; PARKINSONS-DISEASE; HOUSEKEEPING GENES; CSF BIOMARKERS; BETA-ACTIN; PROTEOMICS; QUANTIFICATION; VALIDATION; EXPRESSION;
D O I
10.1016/j.jneumeth.2015.05.011
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
Background: Cerebrospinal fluid (CSF) has been used to identify biomarkers of neurological disease. CSF protein biomarkers identified by high-throughput methods, however, require further validation. While Western blotting (WB) is well-suited to this task, the lack of a validated loading control for CSF WB limits the method's accuracy. New method: We investigated the use of total protein (TP) as a CSFWB loading control. Using iodine-based reversible membrane staining, we determined the linear range and consistency of the CSF TP signal. We then spiked green fluorescent protein (GFP) into CSF to create defined sample-to-sample differences in GFP levels that were measured by WB before and after TP loading correction. Levels of CSF complement C3 and cystatin C measured by WB with TP loading correction and ELISA in amyotrophic lateral sclerosis and healthy control CSF samples were then compared. Results: CSF WB with the TP loading control accurately detected defined differences in GFP levels and corrected for simulated loading errors. Individual CSF sample Western blot and ELISA measurements of complement C3 and cystatin C were significantly correlated and the methods showed a comparable ability to detect between-groups differences. Comparison with existing method: CSF TP staining has a greater linear dynamic range and sample-to-sample consistency than albumin, a commonly used CSF loading control. The method accurately corrects for simulated errors in loading and improves the sensitivity of CSF WB compared to using no loading control. Conclusions: The TP staining loading control improves the sensitivity and accuracy of CSF WB results. (C) 2015 The Authors. Published by Elsevier B.V.
引用
收藏
页码:72 / 82
页数:11
相关论文
共 66 条
[1]
The use of total protein stains as loading controls: An alternative to high-abundance single-protein controls in semi-quantitative immunoblotting [J].
Aldridge, Georgina M. ;
Podrebarac, David M. ;
Greenough, William T. ;
Weiler, Ivan Jeanne .
JOURNAL OF NEUROSCIENCE METHODS, 2008, 172 (02) :250-254
[2]
Cancer biomarker validation: Standards and process - Roles for the National Institute of Standards and Technology (NIST) [J].
Barker, PE .
EPIGENETICS IN CANCER PREVENTION: EARLY DETECTION AND RISK ASSESSMENT, 2003, 983 :142-150
[3]
Aquaporin-4 expression in the cerebrospinal fluid in congenital human hydrocephalus [J].
Castañeyra-Ruiz L. ;
González-Marrero I. ;
González-Toledo J.M. ;
Castañeyra-Ruiz A. ;
de Paz-Carmona H. ;
Castañeyra-Perdomo A. ;
Carmona-Calero E.M. .
Fluids and Barriers of the CNS, 10 (1)
[4]
CEREBROSPINAL-FLUID AS A DIAGNOSTIC BODY-FLUID [J].
CONLY, JM ;
RONALD, AR .
AMERICAN JOURNAL OF MEDICINE, 1983, 75 (1B) :102-108
[5]
Biomarker method validation in anticancer drug development [J].
Cummings, J. ;
Ward, T. H. ;
Greystoke, A. ;
Ranson, M. ;
Dive, C. .
BRITISH JOURNAL OF PHARMACOLOGY, 2008, 153 (04) :646-656
[6]
Cushing H, 1914, J MED RES, V31, P1
[7]
Studies of the pathophysiological mechanisms in frontotemporal dementia by proteome analysis of CSF proteins [J].
Davidsson, P ;
Sjögren, M ;
Andreasen, N ;
Lindbjer, M ;
Nilsson, CL ;
Westman-Brinkmalm, A ;
Blennow, K .
MOLECULAR BRAIN RESEARCH, 2002, 109 (1-2) :128-133
[8]
Evaluating Strategies to Normalise Biological Replicates of Western Blot Data [J].
Degasperi, Andrea ;
Birtwistle, Marc R. ;
Volinsky, Natalia ;
Rauch, Jens ;
Kolch, Walter ;
Kholodenko, Boris N. .
PLOS ONE, 2014, 9 (01)
[9]
Cerebrospinal Fluid Biomarkers for Major Depression Confirm Relevance of Associated Pathophysiology [J].
Ditzen, Claudia ;
Tang, Ning ;
Jastorff, Archana M. ;
Teplytska, Larysa ;
Yassouridis, Alexander ;
Maccarrone, Giuseppina ;
Uhr, Manfred ;
Bronisch, Thomas ;
Miller, Christine A. ;
Holsboer, Florian ;
Turck, Christoph W. .
NEUROPSYCHOPHARMACOLOGY, 2012, 37 (04) :1013-1025
[10]
Sensitive fluorescent detection of protein on nylon membranes [J].
Dubitsky, A ;
DeCollibus, D ;
Ortolano, GA .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 51 (01) :47-56