Simplified in-line sample preparation for amino acid analysis in carbohydrate containing samples

被引:31
作者
Jandik, P [1 ]
Cheng, J [1 ]
Jensen, D [1 ]
Manz, S [1 ]
Avdalovic, N [1 ]
机构
[1] Dionex Corp Res & Dev, Sunnyvale, CA 94088 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2001年 / 758卷 / 02期
关键词
amino acids; carbohydrates;
D O I
10.1016/S0378-4347(01)00179-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report describes a new, automated chromatographic procedure eliminating carbohydrates from amino acid samples prior to their analysis by anion-exchange chromatography and integrated amperometric detection. In the first step, a sample is brought onto a short cation-exchanged column (trap column) in hydrogen form. Carbohydrates are passing through this column, while only amino acids are retained. Subsequently, the cation-exchange column. holding the amino acid fraction, is switched in-line with the gradient pump and separator column. The mobile phase used at the beginning of the separation (NaOH; pH 12.7) transfers amino acids from the trap column onto the anion-exchange column and the amino acid separation is completed without any interference by carbohydrates. All common amino acids are recovered following the carbohydrate removal step. The average value of their recovery is 88.1%. The calibration plots were tested between 12.5 and 500 pmol (amounts injected). The mean value of correlation coefficients of calibration plots was calculated as 0.99. The mean value of relative standard deviations from five replicates was 3.9%. The usefulness of the method is illustrated with two chromatograms of a carrot juice sample obtained before and after the in-line removal of carbohydrates. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:189 / 196
页数:8
相关论文
共 10 条
[1]   HAWORTH MEMORIAL LECTURE - SUGAR-CATION COMPLEXES - STRUCTURE AND APPLICATIONS [J].
ANGYAL, SJ .
CHEMICAL SOCIETY REVIEWS, 1980, 9 (04) :415-428
[3]   An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography [J].
Clarke, AP ;
Jandik, P ;
Rocklin, RD ;
Liu, Y ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2774-2781
[4]   Analyzing mixtures of amino acids and carbohydrates using bi-modal integrated amperometric detection [J].
Jandik, P ;
Clarke, AP ;
Avdalovic, N ;
Andersen, DC ;
Cacia, J .
JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (01) :193-201
[5]   New technique for increasing retention of arginine on an anion-exchange column [J].
Jandik, P ;
Cheng, J ;
Jensen, D ;
Manz, S ;
Avdalovic, N .
ANALYTICAL BIOCHEMISTRY, 2000, 287 (01) :38-44
[6]  
JANDIK P, 2001, METHODS MOL BIOL, V159
[7]  
KHYM JX, 1974, ANAL ION EXCHANGE PR
[8]   Carbohydrate analyses with high-performance anion-exchange chromatography [J].
Lee, YC .
JOURNAL OF CHROMATOGRAPHY A, 1996, 720 (1-2) :137-149
[9]  
Neue U.D., 1997, HPLC COLUMNS
[10]   AUTOMATIC RECORDING APPARATUS FOR USE IN THE CHROMATOGRAPHY OF AMINO ACIDS [J].
SPACKMAN, DH ;
STEIN, WH ;
MOORE, S .
ANALYTICAL CHEMISTRY, 1958, 30 (07) :1190-1206