Imaging breasts with silicone implants

被引:36
作者
Azavedo, E [1 ]
Boné, B
机构
[1] Karolinska Hosp, Dept Diagnost Radiol, S-17176 Stockholm, Sweden
[2] Huddinge Univ Hosp, Karolinska Inst, Dept Diagnost Radiol, S-14186 Huddinge, Sweden
关键词
augmented breasts; silicon breasts; breast imaging;
D O I
10.1007/s003300050679
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Over the last two decades, the use of breast implants both for breast augmentation and for breast reconstruction following mastectomy has increased substantially. It is estimated that around two million women have undergone breast augmentation, while hundreds of thousands have bad breast reconstruction surgery. Different types of material have been used for breast implants, but silicone gel implants have been the dominating implant type. Many implants can lead to complications, such as hardening and rupture, and may therefore need in vivo evaluation by imaging, particularly if they lead to clinical symptoms. They can also pose problems in the assessment of surrounding breast tissue by conventional mammography. In this respect, imaging modalities such as ultrasound, computed tomography and magnetic resonance imaging offer greater possibilities to assess a failing implant, as well as surrounding breast tissue. Several factors, mainly of a psychological nature, lead to requests for breast implants. In this review article, only the imaging aspects of breasts with silicone gel implants will be dealt with. Each modality is concisely presented with its possibilities and limitations.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 59 条
[1]   COMPARATIVE SILICONE BREAST IMPLANT EVALUATION USING MAMMOGRAPHY, SONOGRAPHY, AND MAGNETIC-RESONANCE-IMAGING - EXPERIENCE WITH 59 IMPLANTS [J].
AHN, CY ;
DEBRUHL, ND ;
GORCZYCA, DP ;
SHAW, WW ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1994, 94 (05) :620-627
[2]   SILICONE IMPLANT RUPTURE DIAGNOSIS USING COMPUTED-TOMOGRAPHY - A CASE-REPORT AND EXPERIENCE WITH 22 SURGICALLY REMOVED IMPLANTS [J].
AHN, CY ;
DEBRUHL, ND ;
GORCZYCA, DP ;
BASSETT, LW ;
SHAW, WW .
ANNALS OF PLASTIC SURGERY, 1994, 33 (06) :624-628
[3]   DEFINITIVE DIAGNOSIS OF BREAST IMPLANT RUPTURE USING MAGNETIC-RESONANCE-IMAGING [J].
AHN, CY ;
SHAW, WW ;
NARAYANAN, K ;
GORCZYCA, DP ;
SINHA, S ;
DEBRUHL, ND ;
BASSETT, LW .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1993, 92 (04) :681-691
[4]   THE DIAGNOSIS OF RUPTURED BREAST IMPLANTS [J].
ANDERSEN, B ;
HAWTOF, D ;
ALANI, H ;
KAPETANSKY, D .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1989, 84 (06) :903-907
[5]  
BARLOW RE, 1980, AJR, V135, P179
[6]   DIAGNOSING BREAST IMPLANT RUPTURE WITH MR-IMAGING, US, AND MAMMOGRAPHY [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA ;
KUHLMAN, JE .
RADIOGRAPHICS, 1993, 13 (06) :1323-1336
[7]   SINGLE-LUMEN AND DOUBLE-LUMEN SILICONE BREAST IMPLANT INTEGRITY - PROSPECTIVE EVALUATION OF MR AND US CRITERIA [J].
BERG, WA ;
CASKEY, CI ;
HAMPER, UM ;
KUHLMAN, JE ;
ANDERSON, ND ;
CHANG, BW ;
SHETH, S ;
ZERHOUNI, EA .
RADIOLOGY, 1995, 197 (01) :45-52
[8]  
BONE B, 1995, ACTA RADIOL, V36, P111
[9]   SILICONE BREAST IMPLANTS - HISTORY, SAFETY, AND POTENTIAL COMPLICATIONS [J].
BRIDGES, AJ ;
VASEY, FB .
ARCHIVES OF INTERNAL MEDICINE, 1993, 153 (23) :2638-2644
[10]   FACT AND FICTION ABOUT BREAST IMPLANT BLEED [J].
BRODY, GS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 60 (04) :615-616