In Vivo Comparison Between Optical Coherence Tomography and Intravascular Ultrasound for Detecting Small Degrees of In-Stent Neointima After Stent Implantation

被引:109
作者
Suzuki, Yoriyasu
Ikeno, Fumiaki
Koizumi, Tomomi
Tio, Fermin [2 ]
Yeung, Alan C.
Yock, Paul G.
Fitzgerald, Peter J.
Fearon, William F. [1 ]
机构
[1] Stanford Univ, Med Ctr, Div Cardiovasc Med, Stanford, CA 94305 USA
[2] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
关键词
D O I
10.1016/j.jcin.2007.12.007
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The purpose of this study was to evaluate optical coherence tomography (OCT) for detecting small degrees of in-stent neointima (ISN) after stent implantation compared with intravascular ultrasound (IVUS). Background The importance of detecting neointimal coverage of stent struts has grown with the appreciation of the increased risk for late stent thrombosis after drug-eluting stent (DES) implantation. Intravascular ultrasound, the current standard for evaluating the status of DES, lacks the resolution to detect the initial neointimal coverage. Optical coherence tomography has greater resolution but has not yet been compared with IVUS in vivo with histological correlation for validation. Methods Intravascular ultrasound and OCT were performed with motorized pullback imaging in 6 pigs across 33 stents, 1 month after implantation. Each pig was euthanized, and histological measurements of vessel, stent, and lumen dimensions were performed in 3 sections of each stent. A small degree of ISN was defined as occupying <30% of the stent area measured with histology. The IVUS, OCT, and histological assessment of ISN were compared in matched cross-sections of the stents with a small degree of ISN. Results Eleven stents had a small degree of ISN (average ISN area: 1.26 +/- 0.46 mm(2), and percent area obstruction: 21.4 +/- 5.2%). Compared with histology, the diagnostic accuracy of OCT (area under the receiver operating characteristic curve [AUC] = 0.967, 95% confidence interval [CI] 0.914 to 1.019) was higher than that of IVUS (AUC = 0.781, 95% CI 0.621 to 0.838). Conclusions Optical coherence tomography detects smaller degrees of ISN more accurately than IVUS and might be a useful method for identifying neointimal coverage of stent struts after DES implantation. (J Am Coll Cardiol Intv 2008;1:168-73) (C) 2008 by the American College of Cardiology Foundation
引用
收藏
页码:168 / 173
页数:6
相关论文
共 17 条
[11]   Drug-eluting stent thrombosis -: Results from a pooled analysis including 10 randomized studies [J].
Moreno, R ;
Fernández, C ;
Hernández, R ;
Alfonso, F ;
Angiolillo, DJ ;
Sabaté, M ;
Escaned, J ;
Bañuelos, C ;
Fernández-Ortiz, A ;
Macaya, C .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (06) :954-959
[12]   Diagnostic accuracy of optical coherence tomography and intravascular ultrasound for the detection and characterization of atherosclerotic plaque composition in ex-vivo coronary specimens: a comparison with histology [J].
Rieber, Johannes ;
Meissner, Oliver ;
Babaryka, Gregor ;
Reim, Susanne ;
Oswald, Melanie ;
Koenig, Andreas ;
Schiele, Thomas M. ;
Shapiro, Michael ;
Theisen, Karl ;
Reiser, Maximilian F. ;
Klauss, Volker ;
Hoffmann, Udo .
CORONARY ARTERY DISEASE, 2006, 17 (05) :425-430
[13]   Intravascular ultrasound findings in the multicenter, randomized, double-blind RAVEL (RAndomized study with the sirolimus-eluting VElocity balloon-expandable stent in the treatment of patients with de novo native coronary artery Lesions) Trial [J].
Serruys, PW ;
Degertekin, M ;
Tanabe, K ;
Abizaid, A ;
Sousa, JE ;
Colombo, A ;
Guagliumi, G ;
Wijns, W ;
Lindeboom, WK ;
Ligthart, J ;
de Feyter, PJ ;
Morice, MC .
CIRCULATION, 2002, 106 (07) :798-803
[14]  
Suzuki Yoriyasu, 2006, J Invasive Cardiol, V18, P111
[15]   Evaluation by optical coherence tomography of neointimal coverage of sirolimus-eluting stent three months after implantation [J].
Takano, Masamichi ;
Inami, Shigenobu ;
Jang, Ik-Kyung ;
Yamamoto, Masanori ;
Murakami, Daisuke ;
Seimiya, Koji ;
Ohba, Takayoshi ;
Mizuno, Kyoichi .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08) :1033-1038
[16]   Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent should we be cautious? [J].
Virmani, R ;
Guagliumi, G ;
Farb, A ;
Musumeci, G ;
Grieco, N ;
Motta, T ;
Mihalcsik, L ;
Tespili, M ;
Valsecchi, O ;
Kolodgie, FD .
CIRCULATION, 2004, 109 (06) :701-705
[17]   Characterization of human atherosclerosis by optical coherence tomography [J].
Yabushita, H ;
Bourna, BE ;
Houser, SL ;
Aretz, T ;
Jang, IK ;
Schlendorf, KH ;
Kauffman, CR ;
Shishkov, M ;
Kang, DH ;
Halpern, EF ;
Tearney, GJ .
CIRCULATION, 2002, 106 (13) :1640-1645