Totally endoscopic computer-enhanced atrial septal defect closure in six patients

被引:65
作者
Torracca, L [1 ]
Ismeno, G [1 ]
Alfieri, O [1 ]
机构
[1] Hosp San Raffaele, Div Cardiac Surg, I-20132 Milan, Italy
关键词
D O I
10.1016/S0003-4975(01)02990-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Totally endoscopic procedures have been introduced into cardiac surgery with the application of telemanipulating robotic systems. We report 6 cases of closed-chest atrial septal defect (ASD) closure using a robotic device. Methods. After deflating the right lung, the endoscopic camera and two robotic arms were inserted into the right hemithorax through 8-mm ports. An accessory port was placed for blood suction and for introduction of ancillary endoscopic instruments. After femoral-femoral cannulation for cardiopulmonary bypass (CPB), aortic occlusion, and cardioplegia delivery, the intracardiac correction was carried out in 5 patients with an ostium secundum ASD and in 1 patient with a patent foramen ovale (PFO) and atrial septal aneurysm (ASA). The ASDs were closed with a continuous braided polyester suture. The PFO closure with septal aneurysm plication was carried out with interrupted stiches. Results. Mean CPB and cross-clamp times were 106 +/- 22 and 67 +/- 13 minutes, respectively. Extubation was carried out within the seventh postoperative hour. All patients returned to normal function within the first postoperative week. Conclusions. Totally endoscopic ASD closure can be carried out safely using robotic techniques with rapid postoperative recovery and an excellent cosmetic result. (C) 2001 by The Society of Thoracic Surgeons.
引用
收藏
页码:1354 / 1357
页数:4
相关论文
共 29 条
[1]  
Autschbach R, 1999, Z KARDIOL, V88, P42
[2]   Transcatheter closure as standard treatment for most interatrial defects:: experience in 200 patients treated with the Amplatzer™ Septal Occluder [J].
Berger, F ;
Ewert, P ;
Björnstad, PG ;
Dähnert, I ;
Krings, G ;
Brilla-Austgenat, I ;
Vogel, M ;
Lange, PE .
CARDIOLOGY IN THE YOUNG, 1999, 9 (05) :468-473
[3]   Minimally invasive repair of atrial septal defects [J].
Black, MD ;
Freedom, RM .
ANNALS OF THORACIC SURGERY, 1998, 65 (03) :765-767
[4]   Surgical removal of atrial septal defect occlusion system-devices [J].
Bohm, J ;
Bittigau, K ;
Kohler, F ;
Baumann, G ;
Konertz, W .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1997, 12 (06) :869-872
[5]   Minimally invasive direct access for repair of atrial septal defect in adults [J].
Byrne, JG ;
Adams, DH ;
Mitchell, ME ;
Cohn, LH .
AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (08) :919-922
[6]   Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method [J].
Ewert, P ;
Berger, F ;
Daehnert, I ;
van Wees, J ;
Gittermann, M ;
Abdul-Khaliq, H ;
Lange, PE .
CIRCULATION, 2000, 101 (08) :847-849
[7]   Quality of computer enhanced totally endoscopic coronary bypass graft anastomosis - comparison to conventional technique [J].
Falk, V ;
Gummert, JF ;
Walther, T ;
Hayase, M ;
Berry, GJ ;
Mohr, FW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1999, 15 (03) :260-264
[8]   Dexterity enhancement in endoscopic surgery by a computer-controlled mechanical wrist [J].
Falk, V ;
McLoughlin, J ;
Guthart, G ;
Salisbury, JK ;
Walther, T ;
Gummert, J ;
Mohr, FW .
MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1999, 8 (04) :235-242
[9]  
FALK V, 1999, MINIMAL ACCESS CARDI
[10]   Transcatheter closure of secundum atrial septal defects with the new self-centering Amplatzer Septal Occluder [J].
Fischer, G ;
Kramer, HH ;
Stieh, J ;
Harding, P ;
Jung, O .
EUROPEAN HEART JOURNAL, 1999, 20 (07) :541-549