Are self-expanding stents superior to balloon-expanded in dilating aortas? An experimental study in pigs

被引:20
作者
Mangell, P
Malina, M
Vogt, K
Lindh, M
Schroeder, T
Risberg, B
Brunkwall, J
Lanne, T
机构
[1] Department of Surgery, Lund University, Malmo University Hospital
关键词
endovascular stents; aorta; ultrasound; diameter; distensibility;
D O I
10.1016/S1078-5884(96)80246-2
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To study the stent/vessel interaction and distensibility following the natural increase in vascular diameter using self-expanding and balloon-expanded stents. Design: Open experimental study. Setting: Animal laboratory, university hospital. Materials and Methods: Eight Palmaz (P) and eight Gianturco (G) stents were transluminally placed in the infrarenal aortas of 16 pigs. Pulsatile diameter changes above, at and below the stents were non-invasively monitored with an ultrasound phase-locked echo-tracking system before and immediately after stenting and at 4 and 18 weeks. Blood pressure was registered intra-arterially and stiffness (beta) was calculated. Intravascular ultrasound (IVUS) Tons performed at 18 weeks. Results: Median weight increased from 20 kg (19-26) to 93 kg (62-130). Diameter of the aorta increased 60%. In group P no pulsatile diameter change could be measured at the stent (beta = infinity). In group G stenting increased stiffness from beta 20.7 (9.2) to 43.2 (8.0) (p < 0.05). After 18 weeks stiffness returned to beta 20.1 (12.4). Expanded, median diameter of the P stents was 7.4 (0.8) min, not increasing after 18 weeks. Initial diameter of the G stents tons 7.8 (1.0) mm, increasing 56% to 12.2 (2.3) mm (p < 0.05). IVUS revealed the G stents to be well attached to the vascular wall, but five P stents were detached within half of the circumference. Conclusion: Self-expanding stents follow the pulsatile diameter change of the vessel wall, not adversely affecting distensibility after 18 weeks. They show good attachment despite 56% dilation. In contrast, the balloon-expanded stents do not show pulsatile movement and may detach during vessel diameter increase. This may be of importance when choosing stents for endovascular treatment of abdominal aortic aneurysms.
引用
收藏
页码:287 / 294
页数:8
相关论文
共 28 条
  • [1] EFFECT OF COMPLIANCE MISMATCH ON VASCULAR GRAFT PATENCY
    ABBOTT, WM
    MEGERMAN, J
    HASSON, JE
    LITALIEN, G
    WARNOCK, DF
    [J]. JOURNAL OF VASCULAR SURGERY, 1987, 5 (02) : 376 - 382
  • [2] CHANGES IN ARTERIAL-WALL COMPLIANCE AFTER ENDOVASCULAR STENTING
    BACK, M
    KOPCHOK, G
    MUELLER, M
    CAVAYE, D
    DONAYRE, C
    WHITE, RA
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) : 905 - 911
  • [3] CALCULATION OF PULSE-WAVE VELOCITY USING CROSS-CORRELATION - EFFECTS OF REFLEXES IN THE ARTERIAL TREE
    BENTHIN, M
    DAHL, P
    RUZICKA, R
    LINDSTROM, K
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (05) : 461 - 469
  • [4] TRANSFEMORAL ENDOVASCULAR AORTIC GRAFT PLACEMENT
    CHUTER, TAM
    GREEN, RM
    OURIEL, K
    FIORE, WM
    DEWEESE, JA
    QUERAL, LA
    CRIADO
    NATH, RL
    BERKOWITZ, HD
    SUMPIO, BE
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (02) : 185 - 197
  • [5] INFRARENAL AORTIC-ANEURYSM STRUCTURE - IMPLICATIONS FOR TRANSFEMORAL REPAIR
    CHUTER, TAM
    GREEN, RM
    OURIEL, K
    DEWEESE, JA
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 20 (01) : 44 - 50
  • [6] ENDOVASCULAR TREATMENT OF ABDOMINAL AORTIC OCCLUSIVE DISEASE - THE IMPACT OF STENTS AND INTRAVASCULAR ULTRASOUND IMAGING
    DIETHRICH, EB
    [J]. EUROPEAN JOURNAL OF VASCULAR SURGERY, 1993, 7 (03): : 228 - 236
  • [7] TRANSLUMINALLY-PLACED COILSPRING ENDARTERIAL TUBE GRAFTS - LONG-TERM PATENCY IN CANINE POPLITEAL ARTERY
    DOTTER, CT
    [J]. INVESTIGATIVE RADIOLOGY, 1969, 4 (05) : 329 - +
  • [8] INTRAVASCULAR ULTRASONOGRAPHY BEFORE AND AFTER INTERVENTION - IN-VIVO COMPARISON WITH ANGIOGRAPHY
    GERRITSEN, GP
    GUSSENHOVEN, EJ
    THE, SHK
    PIETERMAN, H
    VANDERLUGT, A
    LI, WG
    BOM, N
    VANDIJK, LC
    DUBOIS, NAJJ
    VANURK, H
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (01) : 31 - 40
  • [9] SELF-EXPANDABLE MACROPOROUS NITINOL STENTS FOR TRANSFEMORAL EXCLUSION OF AORTIC-ANEURYSMS IN DOGS - PRELIMINARY-RESULTS
    HAGEN, B
    HARNOSS, BM
    TRABHARDT, S
    LADEBURG, M
    FUHRMANN, H
    FRANCK, C
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (06) : 339 - 342
  • [10] NONINVASIVE MEASUREMENT OF PULSATILE VESSEL DIAMETER CHANGE AND ELASTIC PROPERTIES IN HUMAN ARTERIES - A METHODOLOGICAL STUDY
    HANSEN, F
    BERGQVIST, D
    MANGELL, P
    RYDEN, A
    SONESSON, B
    LANNE, T
    [J]. CLINICAL PHYSIOLOGY, 1993, 13 (06): : 631 - 643