Noninvasive assessment of blood pressure variability in preterm infants

被引:32
作者
Andriessen, P
Schoffelen, RLM
Berendsen, RCM
De Beer, NAM
Oei, SG
Wijn, PFF
Blanco, CE
机构
[1] Maxima Med Ctr, Neonatal Intens Care Unit, NL-5500 MB Veldhoven, Netherlands
[2] Maxima Med Ctr, Dept Clin Phys, NL-5500 MB Veldhoven, Netherlands
[3] Maxima Med Ctr, Dept Gynecol & Obstet, NL-5500 MB Veldhoven, Netherlands
[4] Eindhoven Univ Technol, Dept Elect Engn, NL-5612 AZ Eindhoven, Netherlands
[5] Eindhoven Univ Technol, Dept Phys, NL-5612 AZ Eindhoven, Netherlands
[6] Acad Hosp Maastricht, Dept Pediat, NL-6202 AZ Maastricht, Netherlands
[7] Acad Hosp Maastricht, Div Neonatol, NL-6202 AZ Maastricht, Netherlands
关键词
D O I
10.1203/01.PDR.0000104152.85296.4F
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The feasibility of measuring blood pressure (BP) variability by a noninvasive beat-to-beat finger arterial BP device (Finapres) was assessed in preterm infants. By application of the finger cuff around the infant's wrist, time and frequency domain (spectral power) analysis of noninvasive beat-to-beat BP signals were compared with intra-arterial measurements. A fast Fourier Transform was used to compute the spectral power density from 128-s periods. The low-frequency band (LF; 0.04-0.15 Hz) is partly associated with baroreflex activity. The high-frequency band (HF; 0.4-1.5 Hz) is associated with respiratory activity. In eight subjects above 1000 g, reliable signals could be obtained. We observed a high correlation between noninvasive and intraarterial beat-to-beat systolic BP values (mean r value +/- SD, 0.87 +/- 0.11), with a gain close to 1 (mean gain +/- SD, 1.0 0.4 mm Hg/mm Hg). Finapres estimated beat-to-beat systolic BP changes more accurately than diastolic values. We found a very high amount of linear coupling, expressed as coherence function, between the power spectra of noninvasive and intra-arterial systolic BP measurements. For systolic BP, the (pooled) group mean +/-SEM coherence values were 0.93 +/- 0.00 and 0.91 +/- 0.01 for LF and HF fluctuations, respectively (NS). The wrist method of Finapres in neonates has limited value in estimating absolute BP but is useful in a clinical research situation, where identification of beat-to-beat changes in systolic BP is more important. Finapres provides a noninvasive tool for investigating autonomic cardiovascular regulation (baroreflex sensitivity, spectral analysis of BP fluctuations) in neonates.
引用
收藏
页码:220 / 223
页数:4
相关论文
共 15 条
[1]  
Akselrod S., 1995, Heart Rate Variability, P147
[2]   Cardiovascular fluctuations and transfer function analysis in stable preterm infants [J].
Andriessen, P ;
Koolen, AMP ;
Berendsen, RCM ;
Wijn, PFF ;
ten Broeke, EDM ;
Oei, SG ;
Blanco, CE .
PEDIATRIC RESEARCH, 2003, 53 (01) :89-97
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   RELATIONSHIPS BETWEEN SHORT-TERM BLOOD-PRESSURE FLUCTUATIONS AND HEART-RATE-VARIABILITY IN RESTING SUBJECTS .1. A SPECTRAL-ANALYSIS APPROACH [J].
DEBOER, RW ;
KAREMAKER, JM ;
STRACKEE, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1985, 23 (04) :352-358
[5]   Assessment of spontaneous baroreflex sensitivity in neonates [J].
Drouin, E ;
Gournay, V ;
Calamel, J ;
Mouzard, A ;
Roze, JC .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1997, 76 (02) :F108-F112
[6]   Feasibility of using finger arterial pressure in neonates [J].
Drouin, E ;
Gournay, V ;
Calamel, J ;
Mouzard, A ;
Roze, JC .
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 1997, 77 (02) :F139-F140
[7]   CONSTRUCTING A HEART-RATE-VARIABILITY ANALYSIS SYSTEM [J].
JAFFE, RS ;
FUNG, DL .
JOURNAL OF CLINICAL MONITORING, 1994, 10 (01) :45-58
[8]   THE UPGRADED FINAPRES-2300E - A CLINICAL-EVALUATION OF A CONTINUOUS NONINVASIVE BLOOD-PRESSURE MONITOR [J].
JONES, RDM ;
BROWN, AG ;
ROULSON, CJ ;
SMITH, ID ;
CHAN, SC .
ANAESTHESIA, 1992, 47 (08) :701-705
[9]   SPECTRAL AND SEQUENCE-ANALYSIS OF FINGER BLOOD-PRESSURE VARIABILITY - COMPARISON WITH ANALYSIS OF INTRAARTERIAL RECORDINGS [J].
OMBONI, S ;
PARATI, G ;
FRATTOLA, A ;
MUTTI, E ;
DIRIENZO, M ;
CASTIGLIONI, P ;
MANCIA, G .
HYPERTENSION, 1993, 22 (01) :26-33
[10]   COMPARISON OF FINGER AND INTRA-ARTERIAL BLOOD-PRESSURE MONITORING AT REST AND DURING LABORATORY TESTING [J].
PARATI, G ;
CASADEI, R ;
GROPPELLI, A ;
DIRIENZO, M ;
MANCIA, G .
HYPERTENSION, 1989, 13 (06) :647-655