Experience of using the bioresorbable copolyester poly(DL-lactide-ε-caprolactone) nerve conduit guide Neurolac™ for nerve repair in peripheral nerve defects: Report on a series of 28 lesions

被引:75
作者
Chiriac, S. [1 ]
Facca, S. [1 ]
Diaconu, M. [1 ]
Gouzou, S. [1 ]
Liverneaux, P. [1 ]
机构
[1] Hop Univ Strasbourg, CCOM, Serv Chirurg Main, Dept Hand Surg, F-67403 Illkirch Graffenstaden, France
关键词
nerve; nerve regeneration guide; nerve suture; nerve graft; Neurolac; AUTOGENOUS VEIN GRAFT; REGENERATION; RECONSTRUCTION; IMPLANTATION; HUMANS; MUSCLE;
D O I
10.1177/1753193411422685
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
100224 [整形外科学];
摘要
Synthetic nerve guides are occasionally used to repair nerve defects. The aim of the present work was to analyse the results of Neurolac (TM) use in a series of 23 patients. We operated on 28 nerve lesions located on various sites: arm (n = 1), elbow (n = 5), forearm (n = 4), wrist (n = 2), palm (n = 5), fingers (n = 11). Defects averaged 11.03 mm and were repaired using Neurolac (TM). After an average of 21.9 months' follow up (3-45 months), subjective criteria (pain, cold intolerance, Quick DASH) and objective criteria (strength, Weber and Semmes-Weinstein sensitivity tests) were compared with the contralateral side. Average pain score was 2.17/10. Cold intolerance was reported in fifteen cases. Quick DASH averaged 35.37/100. Grip strength averaged 64.62% of the contralateral side. As regards sensitivity, the difference between the two sides was 18.89 on Weber's test, and 46.92 on Semmes-Weinstein. Defect size did not affect the outcomes. We observed eight complications the most serious being two fistulizations of the Neurolac (TM) device close to a joint and one neuroma. Neurolac (TM) presents some advantages (resorption, semi-permeability, emergency use, tenseless repair) like other synthetic guides used for nerve regeneration and its transparency constitutes an added benefit. However, some difficulty in its handling and its expensiveness represent real disadvantages. Our results are not in favour of its use in repairing hand nerve defects.
引用
收藏
页码:342 / 349
页数:8
相关论文
共 20 条
[1]
A prospective clinical evaluation of biodegradable neurolac nerve guides for sensory nerve repair in the hand [J].
Bertleff, MJOE ;
Meek, MF ;
Nicolai, JPA .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03) :513-518
[2]
BRIDGING NERVE DEFECTS WITH COMBINED SKELETAL-MUSCLE AND VEIN CONDUITS [J].
BRUNELLI, GA ;
BATTISTON, B ;
VIGASIO, A ;
BRUNELLI, G ;
MAROCOLO, D .
MICROSURGERY, 1993, 14 (04) :247-251
[3]
CHIU DTW, 1982, SURGERY, V91, P226
[4]
Axonal regeneration through acellular muscle grafts [J].
Hall, S .
JOURNAL OF ANATOMY, 1997, 190 :57-71
[5]
FAILED DIGITAL NERVE RECONSTRUCTION BY FOREIGN BODY REACTION TO NEUROLAC® NERVE CONDUIT [J].
Hernandez-Cortes, Pedro ;
Garrido, Juan ;
Camara, Miguel ;
O'Valle Ravassa, Francisco .
MICROSURGERY, 2010, 30 (05) :414-416
[6]
Hudson TW, 1999, CLIN PLAST SURG, V26, P617
[7]
THE EARLY HISTORY OF TUBULATION IN NERVE REPAIR [J].
Ijpma, F. F. A. ;
De Graaf, R. C. Van ;
Meek, M. F. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2008, 33E (05) :581-586
[8]
Long-term regeneration of the rat sciatic nerve through a biodegradable poly(DL-lactide-ε-caprolactone) nerve guide:: Tissue reactions with focus on collagen III/IV reformation [J].
Jansen, K ;
Meek, MF ;
van der Werff, JFA ;
van Wachem, PB ;
van Luyn, MJA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 69A (02) :334-341
[9]
Tubulization Techniques in Brachial Plexus Surgery in an Animal Model for Long-Nerve Defects (40 mm) A Pilot Study [J].
Kostopoulos, Epaminondas ;
Konofaos, Petros ;
Frazer, Mauro ;
Terzis, Julia K. .
ANNALS OF PLASTIC SURGERY, 2010, 64 (05) :614-621
[10]
NERVE REGENERATION IN SILICONE CHAMBERS - INFLUENCE OF GAP LENGTH AND OF DISTAL STUMP COMPONENTS [J].
LUNDBORG, G ;
DAHLIN, LB ;
DANIELSEN, N ;
GELBERMAN, RH ;
LONGO, FM ;
POWELL, HC ;
VARON, S .
EXPERIMENTAL NEUROLOGY, 1982, 76 (02) :361-375