Detection of staphylococcal enterotoxin B (SEB) with surface plasmon resonance biosensor

被引:26
作者
Medina, MB [1 ]
机构
[1] USDA ARS, Eastern Reg Res Ctr, Wyndmoor, PA 19038 USA
关键词
D O I
10.1111/j.1745-4581.2003.tb00042.x
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
An automated and rapid method for detection of staphylococcal enterotoxins is needed by the food industry. We have developed a biosensor Sandwich Assay using a surface plasmon resonance (SPR) biosensor for the detection of Staphylococcus aureus enterotoxin B (SEB). The assay is based on the immobilization of SEB antibody, capturing the SEB from the standard solutions or samples, and followed by the capture of the second SEB antibody by the sensor surface. The assay conditions were optimized to detect SEB in Hepes buffer and in ham extracts. The results indicated that SEB can be detected at 2.5 ng/mL of HBST buffer or in ham tissue extract. The calibration lines in 8 replicate analyses were determined from SEB spiked in ham extract and resulted in a mean R-2 of 0.982 (SD = 0.026) and 0.995 (SD = 0.005) from SEB spiked in the supernatant of the centrifuged ham extract. Analysis of 10 and 20 ppb SEB inoculated on the surface of ham slices resulted in recoveries of 70 and 87%, and 62 and 86%, respectively, but at lower doses of 2.5 and 5 ppb SEB, the recoveries were 53, 0 and 65 and 16%, respectively. The extraction procedure can be improved to increase recoveries and the utilization of a more specific antibody can also improve the detection sensitivity. The Biacore method of analysis is semiautomated and can be developed for multi-toxin detection in foods.
引用
收藏
页码:225 / 243
页数:19
相关论文
共 34 条
[11]   Food-related illness and death in the United States [J].
Mead, PS ;
Slutsker, L ;
Dietz, V ;
McCaig, LF ;
Bresee, JS ;
Shapiro, C ;
Griffin, PM ;
Tauxe, RV .
EMERGING INFECTIOUS DISEASES, 1999, 5 (05) :607-625
[12]   Real-time analysis of antibody binding interactions with immobilized E-coli O157:H7 cells using the BIAcore [J].
Medina, MB ;
VanHouten, L ;
Cooke, PH ;
Tu, SI .
BIOTECHNOLOGY TECHNIQUES, 1997, 11 (03) :173-176
[13]   Hygromycin B antibody production and characterization by a surface plasmon resonance biosensor [J].
Medina, MB .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1997, 45 (02) :389-394
[14]   Biosensor studies of the binding of extracellular matrix components with immobilized Escherichia coli O157:H7 and inhibition by polysulfated polysaccharides [J].
Medina, MB .
BIOTECHNOLOGY LETTERS, 2002, 24 (01) :77-84
[15]   Binding interactions of collagen I, laminin and fibronectin with immobilized Escherichia coli O157:H7 using a surface plasmon resonance biosensor [J].
Medina, MB ;
Fratamico, PM .
BIOTECHNOLOGY TECHNIQUES, 1998, 12 (03) :235-240
[16]   Binding of collagen I to Escherichia coli O157:H7 and inhibition by carrageenans [J].
Medina, MB .
INTERNATIONAL JOURNAL OF FOOD MICROBIOLOGY, 2001, 69 (03) :199-208
[17]  
MEDINA MB, 1997, FOOD TESTING ANAL, V3, P14
[18]  
MEDINA MB, 1998, SPIE, V3544, P97
[19]  
MEDINA MB, 1997, FOOD TEST ANAL, V3, P36
[20]   Identification and characterization of staphylococcal enterotoxin types G and I from Staphylococcus aureus [J].
Munson, SH ;
Tremaine, MT ;
Betley, MJ ;
Welch, RA .
INFECTION AND IMMUNITY, 1998, 66 (07) :3337-3348