Requirements for an active spectroscopy diagnostic with neutral beams on the RFX reversed field pinch

被引:5
作者
Carraro, L [1 ]
Puiatti, ME [1 ]
Sattin, F [1 ]
Scarin, P [1 ]
Valisa, M [1 ]
机构
[1] Consorzio RFX, I-35127 Padua, Italy
关键词
D O I
10.1063/1.1149518
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The conceptual feasibility of an active spectroscopic diagnostic on reversed field experiment (RFX) to measure the radial profiles of ion temperature, toroidal and poloidal drift velocities, and main impurity densities is examined. In particular a charge exchange recombination spectroscopy experiment is simulated for carbon and helium impurities. The motional Stark effect on the beam atoms injected into RFX is estimated as a means to measure the magnetic field pitch and intensity. A modulated beam injector (500 Hz) with 2 A of equivalent current and an energy of 50 keV/amu appears to be adequate to perform the measurements over a reasonable range of operational regimes. (C) 1999 American Institute of Physics. [S0034-6748(99)70601-5].
引用
收藏
页码:861 / 864
页数:4
相关论文
共 20 条
[11]   OBSERVATION OF REACTION H0+O8+-]H+(O7+)STAR DURING NEUTRAL-BEAM INJECTION INTO ORMAK [J].
ISLER, RC .
PHYSICAL REVIEW LETTERS, 1977, 38 (23) :1359-1362
[12]   MAGNETIC-FIELD PITCH-ANGLE MEASUREMENTS IN THE PBX-M TOKAMAK USING THE MOTIONAL STARK-EFFECT [J].
LEVINTON, FM ;
FONCK, RJ ;
GAMMEL, GM ;
KAITA, R ;
KUGEL, HW ;
POWELL, ET ;
ROBERTS, DW .
PHYSICAL REVIEW LETTERS, 1989, 63 (19) :2060-2063
[13]   Diagnostic neutral beam and active spectroscopy requirements for the Alcator C-Mod tokamak (invited) [J].
Marmar, ES ;
Terry, JL ;
Rowan, WL ;
Wootton, AJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :265-268
[14]   MOTIONAL STARK-EFFECT UPGRADES ON DIII-D [J].
RICE, BW ;
NILSON, DG ;
WROBLEWSKI, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01) :373-375
[15]   Effect of plasma radial electric field on motional Stark effect measurements and equilibrium reconstruction [J].
Rice, BW ;
Burrell, KH ;
Lao, LL .
NUCLEAR FUSION, 1997, 37 (04) :517-522
[16]   MULTICHORDAL VISIBLE NEAR-UV SPECTROSCOPY ON THE DIII-D TOKAMAK [J].
SERAYDARIAN, RP ;
BURRELL, KH ;
GROEBNER, RJ .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08) :1530-1532
[17]  
SUMMERS HP, 1994, JETIR9406
[18]  
WIESE WL, 1966, ATOMIC TRANSITION PR, V1
[19]   SCANNING POLARIMETER FOR MEASUREMENT OF THE POLOIDAL MAGNETIC-FIELD IN A TOKAMAK [J].
WROBLEWSKI, D ;
HUANG, LK ;
MOOS, HW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (11) :2341-2350
[20]   The effect of E-r on motional-Stark effect measurements of q, a new technique for measuring E-r, and a test of the neoclassical E-r [J].
Zarnstorff, MC ;
Levinton, FM ;
Batha, SH ;
Synakowski, EJ .
PHYSICS OF PLASMAS, 1997, 4 (04) :1097-1102