On the response of a label-free interferon-γ immunosensor utilizing electrochemical impedance spectroscopy

被引:80
作者
Bart, M
Stigter, ECA
Stapert, HR
de Jong, GJ
van Bennekom, WP
机构
[1] Univ Utrecht, Fac Pharmaceut Sci, Dept Biomed Anal, NL-3508 TB Utrecht, Netherlands
[2] Philips Elect Nederland BV, Philips Res, NL-5656 AA Eindhoven, Netherlands
关键词
immunosensor; impedance spectroscopy; electrochemical protein detection; IFN-gamma;
D O I
10.1016/j.bios.2004.10.009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The research on our flow-injection, label-free, non-faradaic impedimetric immunosensor for interferon-gamma (IFN-gamma) has been extended. The sensor is prepared by immobilization of anti-IFN-gamma antibodies on a self-assembled monolayer (SAM) of acetylcysteine, deposited on polycrystalline gold. A multi-frequency impedance method is described, which allows time-resolved measurement of Nyquist plots. To these plots, an equivalent circuit was fitted, which is discussed in terms of a two-layer structure (inner and outer layer) of the interfacial region. Because binding of IFN-gamma mainly causes a decrease of Q (a constant-phase element), this element is considered as the outer layer. Several aspects of the impedimetric sensor response are studied, including the dependence on detection frequency, target concentration and applied dc potential. For quantitative detection of IFN-gamma, an optimum of the signal-to-noise (S/N) ratio of the out-of-phase impedance component (Z'') was found at about 100 Hz. At a dc-potential of +0.2 V versus a saturated calomel reference electrode, the sensor response is higher than at 0.0 V. Logarithmic dose-response curves of IFN-gamma in the concentration range of 10(-18) to 10(-9) M were obtained using two procedures: by successive injections over a single electrode, and by using freshly prepared electrodes for each measurement. Using the latter method, the repeatability is impaired. The need for in situ complementary techniques for a correct interpretation of the studied parameters is discussed. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 59
页数:11
相关论文
共 48 条
  • [1] Atkins P.W, 1986, PHYS CHEM, V3
  • [2] BARD AJ, 1980, ELECTROCHEMICAL METH
  • [3] Development of a confined wall-jet flow-through cell for simultaneous electrochemical and surface plasmon resonance applications
    Bart, M
    van Os, PJHJ
    Kamp, B
    Bult, A
    van Bennekom, WP
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2002, 84 (2-3): : 129 - 135
  • [4] An immunological interleukin-6 capacitive biosensor using perturbation with a potentiostatic step
    Berggren, C
    Bjarnason, B
    Johansson, G
    [J]. BIOSENSORS & BIOELECTRONICS, 1998, 13 (10) : 1061 - 1068
  • [5] Berggren C, 2001, ELECTROANAL, V13, P173, DOI 10.1002/1521-4109(200103)13:3<173::AID-ELAN173>3.0.CO
  • [6] 2-B
  • [7] Capacitance measurements of antibody-antigen interactions in a flow system
    Berggren, C
    Johansson, G
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (18) : 3651 - 3657
  • [8] Detection of protein concentrations with chronopotentiometry
    Bergveld, P
    Eijkel, JCT
    Olthuis, W
    [J]. BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) : 905 - 916
  • [9] BIDOIA ED, 1994, ELECTROCHIM ACTA, V39, P763, DOI 10.1016/0013-4686(94)80021-9
  • [10] A LINEAR KRONIG-KRAMERS TRANSFORM TEST FOR IMMITTANCE DATA VALIDATION
    BOUKAMP, BA
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1995, 142 (06) : 1885 - 1894