An acetylcholinesterase/choline oxidase-based amperometric biosensor as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates

被引:67
作者
Guerrieri, A [1 ]
Palmisano, F [1 ]
机构
[1] Univ Bari, Dipartimento Chim, I-70126 Bari, Italy
关键词
D O I
10.1021/ac000852h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A liquid chromatography (LC) detector based on a fast response and sensitive bienzyme amperometric biosensor for acetylcholine (ACh) and choline (Ch) is described. The detector fabrication consisted of glutaraldehyde co-crosslinking of acetylcholinesterase and choline oxidase with bovine serum albumin on the Pt working electrode of a conventional thin-layer electrochemical flow cell. The influence of some experimental parameters (e,g,, enzyme loading, thickness of the bienzyme layer, flow rate) on the detector characteristics has been studied in order to optimize the analyte response while minimizing band-broadening and distortion. A mobile phase consisting of a phosphate buffer (I, 0.1 M; pH, 6.5) containing 5 mM sodium hexane sulfonate and 10 mM tetramethylammonium phosphate was found to give very satisfactory resolution and peak shape in ion-pair, reversed-phase LC, Linear responses were observed over at least four decades and absolute detection limits (at a signal-to-noise ratio of 3) were 12 and 27 fmol injected for Ch and ACh, respectively. After one month of intensive use in the LC system, the detector retained about 70% of its initial sensitivity. The potential of the described approach is demonstrated by the simultaneous determination of Ch and ACh in rat brain tissue homogenates.
引用
收藏
页码:2875 / 2882
页数:8
相关论文
共 43 条
[1]   DETERMINATION OF ACETYLCHOLINE AND CHOLINE IN RAT-BRAIN TISSUE BY LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY USING AN IMMOBILIZED ENZYME POST COLUMN REACTOR [J].
ASANO, M ;
MIYAUCHI, T ;
KATO, T ;
FUJIMORI, K ;
YAMAMOTO, K .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1986, 9 (01) :199-215
[2]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .1. THEORY [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :27-35
[3]   LC-biosensor system for the determination of the neurotoxin beta-N-oxalyl-L-alpha,beta-diaminopropionic acid [J].
Belay, A ;
Ruzgas, T ;
Csoregi, E ;
Moges, G ;
Tessema, M ;
Solomon, T ;
Gorton, L .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3471-3475
[4]   THEORETICAL-STUDY OF PERMSELECTIVE LAYERS ON AMPEROMETRIC ELECTRODES IN FLOWING STREAMS [J].
BREEN, W ;
CASSIDY, JF ;
LYONS, MEG .
ANALYTICAL CHEMISTRY, 1991, 63 (20) :2263-2268
[5]   ONLINE FERMENTATION PROCESS MONITORING OF CARBOHYDRATES AND ETHANOL USING TANGENTIAL FLOW FILTRATION AND COLUMN LIQUID-CHROMATOGRAPHY [J].
BUTTLER, TA ;
JOHANSSON, KAJ ;
GORTON, LGO ;
MARKOVARGA, GA .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2628-2636
[6]  
Cass A. E. G., 1990, BIOSENSORS PRACTICAL
[7]  
CENTONZE D, 1992, ANN CHIM-ROME, V82, P219
[8]   DETERMINATION OF ACETYLCHOLINE AND CHOLINE IN THE FEMTOMOLE RANGE BY MEANS OF HPLC, A POST-COLUMN ENZYME REACTOR, AND ELECTROCHEMICAL DETECTION [J].
DAMSMA, G ;
VANBUEREN, DL ;
WESTERINK, BHC ;
HORN, AS .
CHROMATOGRAPHIA, 1987, 24 :827-831
[9]  
DUDA CT, 1993, METHODS NEUROTRANS 1, P1
[10]   BIOSPECIFIC DETECTION IN LIQUID-CHROMATOGRAPHY [J].
EMNEUS, J ;
MARKOVARGA, G .
JOURNAL OF CHROMATOGRAPHY A, 1995, 703 (1-2) :191-243