Adhesion of Staphylococcus to orthopaedic metals, an in vivo study

被引:113
作者
Sheehan, E
McKenna, J
Mulhall, KJ
Marks, P
McCormack, D
机构
[1] Mater Hosp, Dept Orthopaed Surg, Dublin 7, Ireland
[2] Trinity Coll Dublin, Dept Bioresources, Dublin 1, Ireland
[3] Cappagh Natl Orthopaed Hosp, Orthopaed Infect Res Ctr, Dublin 11, Ireland
关键词
biofilms; animal models; inoculation; silver; implants;
D O I
10.1016/S0736-0266(03)00152-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study describes a new model of biofilm study in rabbits. The primary focus of this study was to assess biofilm adhesion to orthopaedic metals in their first 48 It in a femoral intramedullary implantation model. Two previous inoculation methods i.e. that of pre- and direct inoculation were studied with two bacterial isolates namely Staphylococcus aureus and epidermidis, on titanium and stainless steel metallic implants. A method of sonication and log dilution/plating was used to assess biofilm bacteria adhering to implants. Silver coated metals were then compared with their respective control metals in the new model. The direct inoculation model gave larger and more reproducible biofilm adhesion to implanted metals. Staphylococcus epidermidis shows lower adhesion ability to metals, and biofilms adhere in greater numbers to stainless steel over titanium. Silver coated metals show no statistical difference over control metals when exposed to orthopaedic biofilms. (C) 2003 Orthopaedic Research Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:39 / 43
页数:5
相关论文
共 22 条
[11]   Antimicrobial effects of positively charged surfaces on adhering Gram-positive and Gram-negative bacteria [J].
Gottenbos, B ;
Grijpma, DW ;
van der Mei, HC ;
Feijen, J ;
Busscher, HJ .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2001, 48 (01) :7-13
[12]  
GRISTINA AG, 1991, ORTHOP CLIN N AM, V22, P363
[13]  
Isiklar ZU, 1996, CLIN ORTHOP RELAT R, P184
[14]  
JOHANSSON A, 1991, CLIN ORTHOP RELAT R, V61, P297
[15]   Adhesion of Staphylococcus aureus to implants with different physicochemical characteristics [J].
Karlov, AV ;
Khlusov, IA ;
Pontak, VA ;
Ignatov, VP ;
Ivin, MA ;
Zinatulina, SY .
BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2002, 134 (03) :277-280
[16]  
Mainil-Varlet P, 2001, J BIOMED MATER RES, V54, P335, DOI 10.1002/1097-4636(20010305)54:3<335::AID-JBM40>3.0.CO
[17]  
2-4
[18]   INFLUENCE OF TYPE OF MEDULLARY NAIL ON THE DEVELOPMENT OF LOCAL INFECTION - AN EXPERIMENTAL-STUDY OF SOLID AND SLOTTED NAILS IN RABBITS [J].
MELCHER, GA ;
CLAUDI, B ;
SCHLEGEL, U ;
PERREN, SM ;
PRINTZEN, G ;
MUNZINGER, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06) :955-959
[19]   USE OF FIBRINOLYTIC AGENTS TO COAT WIRE IMPLANTS TO DECREASE INFECTION - AN ANIMAL-MODEL [J].
NAKAMOTO, DA ;
HAAGA, JR ;
BOVE, P ;
MERRITT, K ;
ROWLAND, DY .
INVESTIGATIVE RADIOLOGY, 1995, 30 (06) :341-344
[20]   INFECTION ADJACENT TO TITANIUM AND BONE-CEMENT IMPLANTS - AN EXPERIMENTAL-STUDY IN RABBITS [J].
SANZEN, L ;
LINDER, L .
BIOMATERIALS, 1995, 16 (16) :1273-1277