The biomechanics of vertebroplasty - The effect of cement volume on mechanical behavior

被引:426
作者
Belkoff, SM
Mathis, JM
Jasper, LE
Deramond, H
机构
[1] Univ Maryland, Dept Orthopaed Surg, Orthopaed Biomech Lab, Baltimore, MD 21201 USA
[2] Lewis Gale Hosp, Dept Radiol, Salem, VA USA
[3] Univ Hosp Amiens, Div Neuroradiol, Amiens, France
关键词
vertebroplasty; PMMA; cement; biomechanics; osteoporosis;
D O I
10.1097/00007632-200107150-00007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. Ex vivo biomechanical study using osteoporotic cadaveric vertebral bodies. Objective. To determine the association between the volume of cement injected during percutaneous vertebroplasty and the restoration of strength and stiffness in osteoporotic vertebral bodies, two investigational cements were studied: Orthocomp (Orthovita, Malvern, PA) and Simplex 20 (Simplex P with 20% by weight barium sulfate content; Stryker-Howmedica-Osteonics, Rutherford, NJ). Summary of Background Data. Previous biomechanical studies have shown that injections of 8-10 mL of cement during vertebroplasty restore or increase vertebral body strength and stiffness; however, the dose-response association between cement volume and restoration of strength and stiffness is unknown. Methods. Compression fractures were experimentally created in 144 vertebral bodies (T6-L5) obtained from 12 osteoporotic spines harvested from female cadavers. After initial strength and stiffness were determined, the vertebral bodies were stabilized using bipedicular injections of cement totaling 2, 4, 6, or 8 mL and recompressed, after which post-treatment strength and stiffness Were measured. Strength and stiffness were considered restored when post-treatment values were not significantly different from initial values. Results. Strength was restored for all regions when 2 mt of either cement was injected. To restore stiffness with Orthocomp, the thoracic and thoracolumbar regions required 4 mt, but the lumbar region required 6 mL. To restore stiffness with Simplex 20, the thoracic and lumbar regions required 4 mL, but the thoracolumbar region required 8 mL. Conclusion. These data provide guidance on the ce ment volumes needed to restore biomechanical integrity to com pressed osteoporotic vertebral bodies.
引用
收藏
页码:1537 / 1541
页数:5
相关论文
共 27 条
[1]   An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture [J].
Belkoff, SM ;
Mathis, JM ;
Fenton, DC ;
Scribner, RM ;
Reiley, ME ;
Talmadge, K .
SPINE, 2001, 26 (02) :151-156
[2]   Biomechanical evaluation of a new bone cement for use in vertebroplasty [J].
Belkoff, SM ;
Mathis, JM ;
Erbe, EM ;
Fenton, DC .
SPINE, 2000, 25 (09) :1061-1064
[3]  
BELKOFF SM, 1999, BONE S, V25, P23
[4]  
Bostrom MP, 1997, SPINE S, V22, P38, DOI DOI 10.1097/00007632-199712151-00007
[5]   Percutaneous vertebroplasty: State of the art [J].
Cotten, A ;
Boutry, N ;
Cortet, B ;
Assaker, R ;
Demondion, X ;
Leblond, D ;
Chastanet, P ;
Duquesnoy, B ;
Deramond, H .
RADIOGRAPHICS, 1998, 18 (02) :311-320
[6]   Percutaneous vertebroplasty for osteolytic metastases and myeloma: Effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up [J].
Cotten, A ;
Dewatre, F ;
Cortet, B ;
Assaker, R ;
Leblond, D ;
Duquesnoy, B ;
Chastanet, P ;
Clarisse, J .
RADIOLOGY, 1996, 200 (02) :525-530
[7]   TOXIC EFFECTS OF METHYLMETHACRYLATE MONOMER ON LEUKOCYTES AND ENDOTHELIAL-CELLS IN-VITRO [J].
DAHL, OE ;
GARVIK, LJ ;
LYBERG, T .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :147-153
[8]  
DALLAP BL, 1999, T ORTHOP RES SOC, V24, P503
[9]   EXPERIMENTAL INVESTIGATIONS ON THE CYTO-TOXIC NATURE OF METHYL-METHACRYLATE [J].
DANILEWICZSTYSIAK, Z .
JOURNAL OF PROSTHETIC DENTISTRY, 1980, 44 (01) :13-16
[10]  
Debussche-Depriester C., 1991, NEURORADIOLOGY, V33, P149