In vitro evaluation of normal and abnormal lungs with ultra-high-resolution CT

被引:25
作者
Ikura, H [1 ]
Shimizu, K
Ikezoe, J
Nagareda, T
Yagi, N
机构
[1] Ehime Univ, Sch Med, Dept Radiol, Shigenobu, Ehime 7910295, Japan
[2] Takarazuka Municipal Hosp, Dept Clin Med, Takarazuka, Hyogo, Japan
关键词
pulmonary structure; small airway; computed tomography; synchrotron radiation;
D O I
10.1097/00005382-200401000-00002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Synchrotron radiation microtomography is a new technique with high directionality of a synchrotron radiation beam and a high-resolution detector array. In this study, we estimated the visualization of the peripheral human lung structure with an ultra-high-resolution computed tomography (CT) system, the synchrotron radiation CT. The synchrotron radiation CT system uses the bending magnet beamline emitted from the 8.0 GeV electron storage ring. Six lung specimens were obtained at autopsy: 3 normal, I cellular alveolitis, I diffuse alveolar damage, and I pulmonary hemorrhage. Each specimen was cut down to a cylindrical sample with 6-mm diameter and 15- to 25-mm height. The synchrotron radiation CT images of these lung samples were obtained using the ultra-high-resolution image detector system with a charge coupled device (CCD) array detector (1024 x 1024 pixels with 12 x 12 mum(2) pixel size). After that, the sample specimens were sliced to 200 mum (micrometer) thickness, and were observed with a stereomicroscope and by contact radiography. Finally, approximately 10-mum thick microscopic images were obtained and compared with the synchrotron radiation CT images. The synchrotron radiation CT could depict the peripheral lung including peripheral airways, airspaces, and alveolar walls individually. Each finding in the 3 disease processes seen on the synchrotron radiation CT images correlated well with the microscopic findings. The synchrotron radiation CT allows microtomographic imaging of human lung specimens with ultra high-spatial resolution (12 mum) on a level approaching that of conventional histopathology, without sectioning.
引用
收藏
页码:8 / 15
页数:8
相关论文
共 19 条
[1]   NONDESTRUCTIVE IMAGING OF INTERNAL STRUCTURES OF FROG (XENOPUS-LAEVIS) EMBRYOS BY SHADOW-PROJECTION X-RAY MICROTOMOGRAPHY [J].
AOKI, S ;
YONEDA, I ;
NAGAI, T ;
UENO, N ;
MURAKAMI, K .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 1994, 33 (4A) :L556-L558
[2]   BLEOMYCIN-INDUCED FIBROSIS IN PIGS - EVALUATION WITH CT [J].
BALAZS, G ;
NOMA, S ;
KHAN, A ;
EACOBACCI, T ;
HERMAN, PG .
RADIOLOGY, 1994, 191 (01) :269-272
[3]   A SYSTEM FOR DUAL ENERGY MICROTOMOGRAPHY OF BONES [J].
ENGELKE, K ;
LOHMANN, M ;
DIX, WR ;
GRAEFF, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 274 (1-2) :380-389
[4]  
GRAEFF W, 1991, HDB SYNCHROTRON RAD, V4, P361
[5]   OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :541-545
[6]   CRITICAL ABSORPTION TOMOGRAPHY OF SMALL SAMPLES - PROPOSED APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .2. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :547-552
[7]  
Heitzman ER, 1984, LUNG RADIOLOGIC PATH, P4
[8]   Hyperoxia-induced diffuse alveolar damage in pigs:: Correlation between thin-section CT and histopathologic findings [J].
Ichikado, K ;
Suga, M ;
Gushima, Y ;
Johkoh, T ;
Iyonaga, K ;
Yokoyama, T ;
Honda, O ;
Shigeto, Y ;
Tomiguchi, S ;
Takahashi, M ;
Itoh, H ;
Ikezoe, J ;
Müller, NL ;
Ando, M .
RADIOLOGY, 2000, 216 (02) :531-538
[9]   THE X-RAY TOMOGRAPHIC MICROSCOPE - 3-DIMENSIONAL PERSPECTIVES OF EVOLVING MICROSTRUCTURES [J].
KINNEY, JH ;
HAUPT, DL ;
NICHOLS, MC ;
BREUNIG, TM ;
MARSHALL, GW ;
MARSHALL, SJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 347 (1-3) :480-486
[10]   Refraction imaging and histologic correlation in excised tissue from a normal human lung: Preliminary report [J].
Kono, M ;
Ohbayashi, C ;
Yamasaki, K ;
Ohno, Y ;
Adachi, S ;
Sugimura, K ;
Suzuki, Y .
ACADEMIC RADIOLOGY, 2001, 8 (09) :898-902