Use of arterial transfer functions for the derivation of aortic waveform characteristics

被引:114
作者
Hope, SA
Tay, DB
Meredith, IT
Cameron, JD
机构
[1] Monash Med Ctr, Cardiovasc Res Ctr, Clayton, Vic 3168, Australia
[2] Monash Univ, Clayton, Vic 3168, Australia
[3] La Trobe Univ, Melbourne, Vic, Australia
关键词
arterial mechanics; augmentation index; blood pressure; tonometry; transfer functions;
D O I
10.1097/00004872-200307000-00017
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective To investigate the utility and accuracy of radial-aortic arterial transfer functions for the derivation of central blood pressure waveforms. Design Prospective measurement of central and peripheral waveforms in patients undergoing coronary angiography or percutaneous coronary intervention. Methods Simultaneous invasive central aortic and noninvasive radial pressure waveforms were recorded in 78 subjects (61 male: 17 female). Data were applied to a single-in put/single-output model for the calculation of a transfer function (TF). Individual TFs were derived by two methods and ensemble averaged TFs obtained for the group. Reverse transformation was performed using each averaged TF applied to the radial data of each subject. Results There was close linear correlation between measured aortic parameters and both radial and TF-derived aortic systolic and diastolic pressures (P< 0.001) and most other waveform parameters. However, despite small mean differences between measured and most TF-derived aortic parameters (systolic pressure 0.8-2.9 mmHg, augmentation index 4.3-5.6%), individual scatter was marked, with 95% limits of agreement of +/- 14.6 mmHg (systolic pressure) and +/-24.4% [augmentation index (AI)]. Indeed, scatter for AI was so marked that measured and derived values were not statistically significantly correlated. Conclusions Transfer functions may be valid for the derivation of some central aortic waveform characteristics. However, in providing neither improved reproducibility nor data on parameters not obtainable from the radial waveform, transfer function techniques may offer no additional clinical benefit. The absence of correlation between measured and TF-derived aortic Al and wide limits of agreement of other parameters should be considered if this technique is utilized in clinical practice.
引用
收藏
页码:1299 / 1305
页数:7
相关论文
共 25 条
[1]   NONINVASIVE ESTIMATES OF AORTIC ROOT PRESSURES - EXTERNAL SUBCLAVIAN ARTERIAL PULSE TRACING CALIBRATED BY OSCILLOMETRICALLY DETERMINED BRACHIAL ARTERIAL PRESSURES [J].
AAKHUS, S ;
TORP, H ;
HAUGLAND, T ;
HATLE, L .
CLINICAL PHYSIOLOGY, 1993, 13 (06) :573-586
[2]   Systemic arterial compliance is reduced in young patients with IDDM [J].
Berry, KL ;
Skyrme-Jones, RAP ;
Cameron, JD ;
O'Brien, RC ;
Meredith, IT .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1999, 276 (06) :H1839-H1845
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   EXERCISE TRAINING INCREASES TOTAL SYSTEMIC ARTERIAL COMPLIANCE IN HUMANS [J].
CAMERON, JD ;
DART, AM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (02) :H693-H701
[6]  
Chalmers J, 1999, J HYPERTENS, V17, P151
[7]   Validation of carotid artery tonometry as a means of estimating augmentation index of ascending aortic pressure [J].
Chen, CH ;
Ting, CT ;
Nussbacher, A ;
Nevo, E ;
Kass, DA ;
Pak, P ;
Wang, SP ;
Chang, MS ;
Yin, FCP .
HYPERTENSION, 1996, 27 (02) :168-175
[8]  
Chen CH, 1997, CIRCULATION, V95, P1827
[9]   BLOOD-PRESSURE, STROKE, AND CORONARY HEART-DISEASE .2. SHORT-TERM REDUCTIONS IN BLOOD-PRESSURE - OVERVIEW OF RANDOMIZED DRUG TRIALS IN THEIR EPIDEMIOLOGIC CONTEXT [J].
COLLINS, R ;
PETO, R ;
MACMAHON, S ;
HEBERT, P ;
FIEBACH, NH ;
EBERLEIN, KA ;
GODWIN, J ;
QIZILBASH, N ;
TAYLOR, JO ;
HENNEKENS, CH .
LANCET, 1990, 335 (8693) :827-838
[10]   Parametric model derivation of transfer function for noninvasive estimation of aortic pressure by radial tonometry [J].
Fetics, B ;
Nevo, E ;
Chen, CH ;
Kass, DA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (06) :698-706