A novel approach to measuring circulating blood volume: The use of a hemoglobin-based oxygen carrier in a rabbit model

被引:18
作者
Jahr, JS
Lurie, F
Xi, S
Golkaryeh, M
Kuznetsova, O
Kullar, R
Driessen, B
机构
[1] Univ Penn, New Bolton Ctr, Dept Clin Studies, Kennett Sq, PA USA
[2] Univ Calif Davis, Dept Pediat, Sacramento, CA 95817 USA
[3] Univ Calif Davis, Dept Anesthesiol & Pain Med, Sacramento, CA 95817 USA
关键词
D O I
10.1213/00000539-200103000-00010
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Hemoglobin-based oxygen carriers (HBOC) may be ideal for monitoring circulating plasma volume (CV-P) and circulating blood volume (CV-B). We used an HBOC (Hemoglobin glutamer-200 [bovine], Oxyglobin(R); Biopure, Cambridge, MA) as an indicator for relative CV-B in the rabbit model. Accuracy of the technique was determined by comparison with the Evans blue dye (EBD) dilution technique in 19 anesthetized female New Zealand rabbits weighing 2.0 to 10.6 kg. The measurements were per formed at baseline, after hemorrhage (1/3 of CV-B), normovolemic hemodilution (replacement of 1/3 CV-B by Hextend(R); Abbot Laboratories, North Chicago, IL), and hypervolemic hemodilution (additional infusion of Hextend(R) in a volume equal to 1/3 of CV-B). Hemoglobin concentration was measured by using a HemoCue(R) photometer (HemoCue AB, Angelholm, Sweden). EBD concentration was analyzed by using linear regression to estimate Time 0 concentration; Time 0 was defined as EBD injection time. The difference between CV-P values determined by EBD and HBOC dilution was independent from the magnitude of the CV-P value. The relative bias was 1.29 mL and the precision (one SD) was 2.82 mL. The difference did not reach statistical significance.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 19 条
[11]   ACCURACY AND REPRODUCIBILITY OF THE MEASUREMENT OF ACTIVELY CIRCULATING BLOOD-VOLUME WITH AN INTEGRATED FIBEROPTIC MONITORING-SYSTEM [J].
KISCH, H ;
LEUCHT, S ;
LICHTWARCKASCHOFF, M ;
PFEIFFER, UJ .
CRITICAL CARE MEDICINE, 1995, 23 (05) :885-893
[12]  
Lurie F, 2000, ANESTHESIOLOGY, V93, pU153
[13]  
LURIE F, IN PRESS VET CLIN PA
[14]  
MANNING PT, 1994, BIOL LAB RABBIT, P124
[15]   Blood volume and cardiac index in rats after exchange transfusion with hemoglobin-based oxygen carriers [J].
Migita, R ;
Gonzales, A ;
Gonzales, ML ;
Vandegriff, KD ;
Winslow, RM .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 82 (06) :1995-2002
[16]   High predictive value of red cell volume measurement using carboxy haemoglobin in a rabbit model of haemorrhage [J].
Obata, H ;
Goto, F ;
Nara, T ;
Kunimoto, F ;
Oriuchi, N ;
Mishiba, E ;
Nemoto, M .
BRITISH JOURNAL OF ANAESTHESIA, 1998, 81 (06) :940-944
[17]  
PETTIT JE, 1980, J NUCL MED, V21, P793
[18]   RECOMBINANT HUMAN HEMOGLOBIN (RHB1.1) SELECTIVELY INHIBITS VASORELAXATION ELICITED BY NITRIC-OXIDE DONORS IN RABBIT ISOLATED AORTIC RINGS [J].
RIOUX, F ;
DRAPEAU, G ;
MARCEAU, F .
JOURNAL OF CARDIOVASCULAR PHARMACOLOGY, 1995, 25 (04) :587-594
[19]  
1998, FED REG, V63, P11598