A Fe3O4-based chemical sensor for cathodic determination of hydrogen peroxide

被引:138
作者
Lin, MS [1 ]
Len, HJ [1 ]
机构
[1] Tamkang Univ, Dept Chem, Tamsui 25137, Taiwan
关键词
Fe3O4; hydrogen peroxide; amperometric; sensor; chitosan;
D O I
10.1002/elan.200503335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new cathodic scheme for hydrogen peroxide (H2O2) measurement by Fe3O4-based chemical sensor was described. The unique characteristic of electrocatalytic property was firstly investigated by voltammetry. And then the amperometric response of H2O2 was measured at - 0.2 V (vs. Ag/AgCl) by Fe3O4 modified glassy carbon rotating disk electrode. The kinetic parameter was also calculated from Koutecky-Levich plot, and the value was 6.4 x 10(-4) cm s(-1) in pH 3 citrate buffer. In order to benefit the possible biomedical applications, Fe3O4/chitosan modified electrode was also investigated in this experiment. There were several characteristic enhancements by the coated chitosan thin film for H2O2 sensor. The calibration curves were found to be linear up to 4.0 and 5.0 mM (r = 0.999) in pH 3 and 7 with the detection limits of 7.6 and 7.4 mu M L-1 (S/N = 3). The stability was evaluated by the results of half-life time (t(50%)) for 9 months at room temperature and 24 months at 4 degrees C.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 47 条
[1]   Simultaneous electroanalysis of peroxyacetic acid and hydrogen peroxide [J].
Awad, MI ;
Harnoode, C ;
Tokuda, K ;
Ohsaka, T .
ANALYTICAL CHEMISTRY, 2001, 73 (08) :1839-1843
[2]   MAGNETOTACTIC BACTERIA [J].
BLAKEMORE, R .
SCIENCE, 1975, 190 (4212) :377-379
[3]  
Brown D. B., 1980, Mixed-Valence Compounds: Theory and Applications in Chemistry, Physics, Geology, and Biology
[4]   A selective, cell-permeable optical probe for hydrogen peroxide in living cells [J].
Chang, MCY ;
Pralle, A ;
Isacoff, EY ;
Chang, CJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (47) :15392-15393
[5]   Bioinorganic composites for enzyme electrodes [J].
Chen, L ;
Gorski, W .
ANALYTICAL CHEMISTRY, 2001, 73 (13) :2862-2868
[6]   Electrode coatings based on chitosan scaffolds [J].
Cruz, J ;
Kawasaki, M ;
Gorski, W .
ANALYTICAL CHEMISTRY, 2000, 72 (04) :680-686
[7]   Determination of hydrogen peroxide using glassy carbon and graphite/polyester composite electrodes modified by vanadium-doped zirconias [J].
Doménech, A ;
Alarcón, J .
ANALYTICA CHIMICA ACTA, 2002, 452 (01) :11-22
[9]   Detection of hydrogen peroxide at mesoporous platinum microelectrodes [J].
Evans, SAG ;
Elliott, JM ;
Andrews, LM ;
Bartlett, PN ;
Doyle, PJ ;
Denuault, G .
ANALYTICAL CHEMISTRY, 2002, 74 (06) :1322-1326
[10]   FLOW-THROUGH OPTICAL BIOSENSOR BASED ON THE PERMANENT IMMOBILIZATION OF AN ENZYME AND TRANSIENT RETENTION OF A REACTION-PRODUCT [J].
FERNANDEZROMERO, JM ;
DECASTRO, MDL .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3048-3052