A Fe3O4-based chemical sensor for cathodic determination of hydrogen peroxide

被引:138
作者
Lin, MS [1 ]
Len, HJ [1 ]
机构
[1] Tamkang Univ, Dept Chem, Tamsui 25137, Taiwan
关键词
Fe3O4; hydrogen peroxide; amperometric; sensor; chitosan;
D O I
10.1002/elan.200503335
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new cathodic scheme for hydrogen peroxide (H2O2) measurement by Fe3O4-based chemical sensor was described. The unique characteristic of electrocatalytic property was firstly investigated by voltammetry. And then the amperometric response of H2O2 was measured at - 0.2 V (vs. Ag/AgCl) by Fe3O4 modified glassy carbon rotating disk electrode. The kinetic parameter was also calculated from Koutecky-Levich plot, and the value was 6.4 x 10(-4) cm s(-1) in pH 3 citrate buffer. In order to benefit the possible biomedical applications, Fe3O4/chitosan modified electrode was also investigated in this experiment. There were several characteristic enhancements by the coated chitosan thin film for H2O2 sensor. The calibration curves were found to be linear up to 4.0 and 5.0 mM (r = 0.999) in pH 3 and 7 with the detection limits of 7.6 and 7.4 mu M L-1 (S/N = 3). The stability was evaluated by the results of half-life time (t(50%)) for 9 months at room temperature and 24 months at 4 degrees C.
引用
收藏
页码:2068 / 2073
页数:6
相关论文
共 47 条
[31]   Determination of hydrogen peroxide by using a flow injection system with immobilized peroxidase and long pathlength capillary spectrophotometry [J].
Pappas, AC ;
Stalikas, CD ;
Fiamegos, YC ;
Karayannis, MI .
ANALYTICA CHIMICA ACTA, 2002, 455 (02) :305-313
[32]   A FLUOROMETRIC ASSAY FOR HYDROGEN-PEROXIDE, SUITABLE FOR NAD(P)H-DEPENDENT SUPEROXIDE GENERATING REDOX SYSTEMS [J].
RAPOPORT, R ;
HANUKOGLU, I ;
SKLAN, D .
ANALYTICAL BIOCHEMISTRY, 1994, 218 (02) :309-313
[33]  
Schwertmann U., 1991, IRON OXIDES LAB
[34]   1,1'-OXALYLDIIMIDAZOLE AS CHEMILUMINESCENCE REAGENT IN THE DETERMINATION OF LOW HYDROGEN-PEROXIDE CONCENTRATIONS BY FLOW-INJECTION ANALYSIS [J].
STIGBRAND, M ;
PONTEN, E ;
IRGUM, K .
ANALYTICAL CHEMISTRY, 1994, 66 (10) :1766-1770
[35]   A THERMOSTABLE HYDROGEN-PEROXIDE SENSOR-BASED ON WIRING OF SOYBEAN PEROXIDASE [J].
VREEKE, MS ;
YONG, KT ;
HELLER, A .
ANALYTICAL CHEMISTRY, 1995, 67 (23) :4247-4249
[36]   Amperometric enzyme electrode for the determination of hydrogen peroxide based on sol-gel/hydrogel composite film [J].
Wang, BQ ;
Zhang, JZ ;
Cheng, GJ ;
Dong, SJ .
ANALYTICA CHIMICA ACTA, 2000, 407 (1-2) :111-118
[37]   Sol-gel thin-film immobilized soybean peroxidase biosensor for the amperometric determination of hydrogen peroxide in acid medium [J].
Wang, BQ ;
Li, B ;
Wang, ZX ;
Xu, GB ;
Wang, Q ;
Dong, SJ .
ANALYTICAL CHEMISTRY, 1999, 71 (10) :1935-1939
[38]   MINIATURIZED GLUCOSE SENSORS BASED ON ELECTROCHEMICAL CODEPOSITION OF RHODIUM AND GLUCOSE-OXIDASE ONTO CARBON-FIBER ELECTRODES [J].
WANG, J ;
ANGNES, L .
ANALYTICAL CHEMISTRY, 1992, 64 (04) :456-459
[39]   ENZYME MICROELECTRODE ARRAY STRIPS FOR GLUCOSE AND LACTATE [J].
WANG, J ;
CHEN, Q .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1007-1011
[40]   HIGHLY SELECTIVE MEMBRANE-FREE, MEDIATOR-FREE GLUCOSE BIOSENSOR [J].
WANG, J ;
LIU, J ;
CHEN, L ;
LU, F .
ANALYTICAL CHEMISTRY, 1994, 66 (21) :3600-3603