Evaluation of the "effective volume shift" method for axial dispersion corrections in multi-detector size exclusion chromatography

被引:20
作者
Jackson, C [1 ]
机构
[1] DuPont Automot, Marshall Lab, Philadelphia, PA 19146 USA
关键词
size exclusion chromatography; band broadening; molar mass distribution;
D O I
10.1016/S0032-3861(98)00590-4
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Band broadening in size exclusion chromatography (SEC) causes errors in the calculated molar mass distribution even when molar-mass-sensitive detectors are used. These errors can be partially corrected by shifting the elution volume of the molar-mass-sensitive detector chromatogram relative to the concentration detector chromatogram, and then re-calculating the molar mass distribution. In this paper a computer simulation of multi-detector SEC of a polymer with a Flory-Schulz molar mass distribution and Gaussian band broadening is used to study the volume shift method of correcting for band broadening. The results are compared with those obtained by applying a conventional band broadening correction. In the case of SEC with a light scattering detector the results from the two methods are comparable. For SEC-viscometry with universal calibration the conventional method is significantly more accurate than the volume shift method. A method for calculating the volume shift required to correct for a known amount of band broadening is also presented. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3735 / 3742
页数:8
相关论文
共 22 条
[1]   SEC-VISCOMETER DETECTOR SYSTEMS .2. RESOLUTION CORRECTION AND DETERMINATION OF INTERDETECTOR VOLUME [J].
CHEUNG, P ;
LEW, R ;
BALKE, ST ;
MOUREY, TH .
JOURNAL OF APPLIED POLYMER SCIENCE, 1993, 47 (09) :1701-1706
[2]  
Gallot-Grubisic Z., 1967, J POLYM SCI, V5, P753
[3]  
HAMIELEC AE, 1984, STERIC EXCLUSION LIQ, P117
[4]   COMPUTER-SIMULATION STUDY OF MULTIDETECTOR SIZE-EXCLUSION CHROMATOGRAPHY OF BRANCHED MOLECULAR-MASS DISTRIBUTIONS [J].
JACKSON, C .
JOURNAL OF CHROMATOGRAPHY A, 1994, 662 (01) :1-12
[5]  
JACKSON C, 1995, ADV CHEM SER, V247, P69
[6]   Comparison of most probable peak values as measured for polymer distributions by MALDI mass spectrometry and by size exclusion chromatography [J].
Jackson, C ;
Larsen, B ;
McEwen, C .
ANALYTICAL CHEMISTRY, 1996, 68 (08) :1303-1308
[7]   COMPUTER-SIMULATION STUDY OF SIZE-EXCLUSION CHROMATOGRAPHY WITH SIMULTANEOUS VISCOMETRY AND LIGHT-SCATTERING MEASUREMENTS [J].
JACKSON, C ;
YAU, WW .
JOURNAL OF CHROMATOGRAPHY, 1993, 645 (02) :209-217
[8]  
Jackson C., 1996, INT J POLYM ANAL CH, V2, P425
[9]   HIGH-TEMPERATURE COUPLING OF HIGH-SPEED GPC WITH CONTINUOUS VISCOMETRY .1. LONG-CHAIN BRANCHING IN POLYETHYLENE [J].
LECACHEUX, D ;
LESEC, J ;
QUIVORON, C .
JOURNAL OF APPLIED POLYMER SCIENCE, 1982, 27 (12) :4867-4877
[10]   CORRECTION FOR AXIAL-DISPERSION OF DATA OBTAINED BY GEL-PERMEATION CHROMATOGRAPHY WITH AN ONLINE VISCOMETER [J].
NETOPILIK, M ;
SCHULZ, G .
ACTA POLYMERICA, 1984, 35 (02) :140-144