Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants

被引:20
作者
Arat, YO [1 ]
Shetlar, DJ [1 ]
Boniuk, M [1 ]
机构
[1] Baylor Coll Med, Dept Ophthalmol, Houston, TX 77030 USA
关键词
D O I
10.1097/01.IOP.0000062850.71572.7D
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
Purpose: To report our experience with bovine pericardium as a wrapping material for hydroxyapatite orbital implants after enucleation and to compare the exposure rates of the implants wrapped with bovine pericardium versus donor sclera. Methods: We retrospectively reviewed the records of all patients who received bovine pericardium-wrapped or donor sclera-wrapped hydroxyapatite implant after primary enucleation between March 1995 and December 2001. Results: Of the 26 patients who received donor sclera-wrapped implants after enucleation, 1 (3.8%) had implant exposure. Of the 26 patients who received bovine pericardium-wrapped implants after enucleation, 6 (23%) had implant exposure. The incidence of implant exposure with the use bovine pericardium wrapping material was found to be significantly higher than with sclera (P=0.05). Six of the 7 implant exposures were noted in the first 6 months after placement of the orbital implant. Five of the 6 exposed bovine pericardium-wrapped hydroxyapatite implants were associated with socket infection. The case of exposure of the sclera-wrapped implant was treated conservatively by observation. Six patients who had exposure of bovine pericardium-wrapped implants required multiple repairs because of recurrent exposures. Four of these patients eventually required removal of the implant. Conclusions: Despite the advantages of using bovine pericardium as a wrapping material for hydroxyapatite orbital implants, we observed a significantly higher incidence of exposure with bovine pericardium compared with donor sclera in the early postoperative period. Use of bovine pericardium as a wrapping material for orbital implants should be avoided unless some future modifications of the technique can be developed to prevent such complications.
引用
收藏
页码:189 / 193
页数:5
相关论文
共 12 条
[1]
Char DH, 2001, BRIT J OPHTHALMOL, V85, P627
[2]
Bovine pericardium versus homologous sclera as wrapping materials for hydroxyapatite ocular implants: An animal study [J].
DeBacker, CM ;
Dutton, JJ ;
Proia, AD ;
Holck, DEE ;
Stone, T .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1999, 15 (05) :312-316
[3]
Bovine pericardium as a wrapping for orbital implants [J].
Gayre, GS ;
Debacker, C ;
Lipham, W ;
Tawfik, HA ;
Holck, D ;
Dutton, JJ .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2001, 17 (05) :381-387
[4]
CURRENT TECHNIQUES OF ENUCLEATION - A SURVEY OF 5,439 INTRAORBITAL IMPLANTS AND A REVIEW OF THE LITERATURE [J].
HORNBLASS, A ;
BIESMAN, BS ;
EVIATAR, JA .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1995, 11 (02) :77-86
[5]
Jordan DR, 1999, OPHTHALMIC SURG LAS, V30, P403
[6]
Hydroxyapatite implant wrapping materials: Analysis of fibrovascular ingrowth in an animal model [J].
Klapper, SR ;
Jordan, DR ;
Punja, K ;
Brownstein, S ;
Gilberg, SM ;
Mawn, LA ;
Grahovac, SZ .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 2000, 16 (04) :278-285
[7]
PERRY AC, 1991, OPHTHALMOL CLIN N AM, V4, P173
[8]
PERRY AC, 1990, ADV OPHTHAL PLAST PL, V8, P7581
[9]
REMULLA HD, 1995, OPHTHALMOLOGY, V102, P586
[10]
CAUSES OF FAILURE AND PATHOLOGICAL FINDINGS IN SURGICALLY REMOVED IONESCU-SHILEY STANDARD BOVINE PERICARDIAL HEART-VALVE BIOPROSTHESES - EMPHASIS ON PROGRESSIVE STRUCTURAL DETERIORATION [J].
SCHOEN, FJ ;
FERNANDEZ, J ;
GONZALEZLAVIN, L ;
CERNAIANU, A .
CIRCULATION, 1987, 76 (03) :618-627