New reference intervals for thyrotropin and thyroid hormones based on national academy of clinical biochemistry criteria and regular ultrasonography of the thyroid

被引:186
作者
Kratzsch, J
Fiedler, GM
Leichtle, A
Brügel, M
Buchbinder, S
Otto, L
Sabri, O
Matthes, G
Thiery, J
机构
[1] Univ Hosp Leipzig, Inst Lab Med Clin Chem & Mol Diagnost, D-04103 Leipzig, Germany
[2] Univ Hosp Leipzig, Inst Transfus Med, D-04103 Leipzig, Germany
[3] Univ Hosp Leipzig, Clin Nucl Med, D-04103 Leipzig, Germany
关键词
D O I
10.1373/clinchem.2004.047399
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The aim of our present study was toestablish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits, of these intervals. Methods: We investigated 870 apparently healthy persons and excluded, step by step, those with a family history of thyroid disease, pathologic thyroid ultrasonography results, and increased anti-thyroid peroxidase or anti-thyroglobulin antibodies. Accordingly, only 453 of the 870 persons in the entire group were finally included as reference collective. We measured serum concentrations of TSH, total and free thyroxine (T-4 and FT4), and total and free triiodothyronine (T-3 and FT3) of the whole and the reference collective on the ELECSYS system assays (Roche Diagnostics) and calculated the 2.5th and 97.5th percentiles for comparison. Results: The calculated lower limit for TSH differed significantly between the reference intervals for healthy persons with an assessed normal thyroid gland vs the nonselected group of healthy blood donors. Age was the only independent factor and was significantly inversely associated with TSH (P < 0.0001). Use of oral contraceptives was a significant predictor for variation in T, concentrations (P < 0.001). Age and oral contraceptives were independently associated with T-3 variations (P < 0.05). For FT, vs FT, variation, gender and (inversely) age (P < 0.01) were independent modulating factors. Conclusions: The selection of healthy persons according to NACB criteria combined with sonographic confirmation of a normal thyroid gland provide a valid basis for the reference interval for TSH. Factors indicating a preclinical disease state, such as family history, pathologic ultrasonography result, or increased antithyroid peroxidase and anti-thyroglobulin antibodies, can be associated with normal hormone concentrations. Additionally, patient age and gender as well as use of contraceptives should be considered in diagnostic evaluation of thyroid diseases. (c) 2005 American Association for Clinical Chemistry.
引用
收藏
页码:1480 / 1486
页数:7
相关论文
共 26 条
[1]   Biologic variation is important for interpretation of thyroid function tests [J].
Andersen, S ;
Bruun, NH ;
Pedersen, KM ;
Laurberg, P .
THYROID, 2003, 13 (11) :1069-1078
[2]   A model for a multicentre approach to the derivation of reference intervals for thyroid hormones and testosterone for laboratories using identical analysers [J].
Andrew, CE ;
Hanning, I ;
McBain, AM ;
Moody, D ;
Price, A .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2000, 38 (10) :1013-1019
[3]  
[Anonymous], 2003, THYROID, V13, P3
[4]  
BROWNING MCK, 1986, CLIN CHEM, V32, P962
[5]   VOLUMETRIC-ANALYSIS OF THYROID LOBES BY REAL-TIME ULTRASOUND [J].
BRUNN, J ;
BLOCK, U ;
RUF, G ;
BOS, I ;
KUNZE, WP ;
SCRIBA, PC .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1981, 106 (41) :1338-1340
[6]   The treatment of subclinical hypothyroidism is seldom necessary [J].
Chu, JW ;
Crapo, LM .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2001, 86 (10) :4591-4599
[7]  
Ebert C, 1998, WIEN KLIN WOCHENSCHR, V110, P27
[8]   Regional reference values for some quantities measured with the ADVIA Centaur analyser.: A model of co-operation between the in vitro diagnostic industry and clinical laboratories [J].
Ferré-Masferrer, M ;
Fuentes-Arderiu, X ;
Gomà-Llongueras, M ;
Alumà-Trullàs, A ;
Aramendi-Ramos, M ;
Castaño-Vidriales, JL ;
Esteban-Salan, M ;
Graells-Ferrer, M ;
Jiménez-González, A ;
Jiménez-Lobo, C ;
López-Esparza, M ;
Parés-Pollán, L ;
Regulez-Uranga, M ;
Riesco-Prieto, M ;
Rodríguez-Camba, A ;
Vidal-Martínez, J .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (02) :166-169
[9]   Population-specific reference values for thyroid hormones on the Abbott ARCHITECT i2000 analyzer [J].
González-Sagrado, M ;
Martín-Gil, FJ .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2004, 42 (05) :540-542
[10]   ULTRASOUND DIAGNOSIS OF THE THYROID [J].
GUTEKUNST, R ;
BECKER, W ;
HEHRMANN, R ;
OLBRICHT, T ;
PFANNENSTIEL, P .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1988, 113 (27) :1109-1112