Methods for in vitro characterization of multichannel nerve tubes

被引:60
作者
de Ruiter, Godard C. [2 ,3 ]
Onyeneho, Irene A. [2 ]
Liang, Ellen T. [2 ]
Moore, Michael J. [4 ]
Knight, Andrew M. [1 ]
Malessy, Martijn J. A. [5 ]
Spinner, Robert J. [3 ]
Lu, Lichun [6 ]
Currier, Bradford L. [6 ]
Yaszemski, Michael J. [6 ]
Windebank, Anthony J. [1 ]
机构
[1] Mayo Clin, Dept Neurol, Rochester, MN 55905 USA
[2] Mayo Clin, Cell Neurobiol Lab, Rochester, MN USA
[3] Mayo Clin, Dept Neurol Surg, Rochester, MN USA
[4] Mayo Clin, Dept Physiol & Biomed Engn, Rochester, MN USA
[5] Leiden Univ, Med Ctr, Dept Neurosurg, Leiden, Netherlands
[6] Mayo Clin, Dept Orthoped, Rochester, MN USA
关键词
degradation; flexibility; nerve regeneration; permeability; swelling; tissue engineering;
D O I
10.1002/jbm.a.31298
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Multichannel conduits have been developed for experimental peripheral nerve and spinal cord repair. We present a series of methods to characterize multichannel nerve tubes for properties of bending, deformation, swelling, and degradation and introduce a new method to test the permeability of multichannel nerve tubes from the rate of diffusion of different-sized fluorescent dextran molecules (10, 40, and 70 kDa). First, single-lumen nerve tubes made with different poly(lactic-co-glycolic acid) (PLGA) ratios (50:50, 75:25, and 85:15) were compared. One ratio (75:25 PLGA) was subsequently used to compare single-lumen and multichannel nerve tubes. Nerve tubes made with lower PLGA ratios were found to be more flexible than nerve tubes made with a higher PLGA ratio. For low ratios, however, swelling was also greater as a result of a faster rate of degradation. Multichannel structure did not interfere with the permeability of the tube; the rate of diffusion into multichannel 75:25 PLGA nerve tubes appeared to be even higher than that into single-lumen ones, but this was only significant for 70-kDa molecules. Also, multichannel 75:25 PLGA nerve tubes were more flexible and, at the same time, more resistant to deformation. However, swelling significantly decreased the total cross-sectional lumen area, especially in multichannel 75:25 PLGA nerve tubes. Permeability, bending, deformation, swelling, and degradation are important properties to characterize in the development of multichannel nerve tubes. The methods presented in this study can be used as a basis for optimizing these properties for future, possibly clinical, application. (C) 2007 Wiley Periodicals, Inc. J Biomed Mater Res.
引用
收藏
页码:643 / 651
页数:9
相关论文
共 31 条
[11]   NERVE REGENERATION THROUGH HOLEY SILICONE TUBES [J].
JENO, CB ;
COGGESHALL, RE .
BRAIN RESEARCH, 1985, 361 (1-2) :233-241
[12]   PERMEABLE TUBES INCREASE THE LENGTH OF THE GAP THAT REGENERATING AXONS CAN SPAN [J].
JENQ, CB ;
COGGESHALL, RE .
BRAIN RESEARCH, 1987, 408 (1-2) :239-242
[13]   COMPARISON OF MACROPORE, SEMIPERMEABLE, AND NONPERMEABLE COLLAGEN CONDUITS IN NERVE REPAIR [J].
KIM, DH ;
CONNOLLY, SE ;
ZHAO, SR ;
BEUERMAN, RW ;
VOORHIES, RM ;
KLINE, DG .
JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 1993, 9 (06) :415-420
[14]  
LI S-T, 1992, Clinical Materials, V9, P195, DOI 10.1016/0267-6605(92)90100-8
[15]  
Li SM, 1999, J BIOMED MATER RES, V48, P342, DOI 10.1002/(SICI)1097-4636(1999)48:3<342::AID-JBM20>3.0.CO
[16]  
2-7
[17]   In vitro and in vivo degradation of porous poly(DL-lactic-co-glycolic acid) foams [J].
Lu, L ;
Peter, SJ ;
Lyman, MD ;
Lai, HL ;
Leite, SM ;
Tamada, JA ;
Uyama, S ;
Vacanti, JP ;
Langer, R ;
Mikos, AG .
BIOMATERIALS, 2000, 21 (18) :1837-1845
[18]  
Lu L, 1999, J BIOMED MATER RES, V46, P236, DOI 10.1002/(SICI)1097-4636(199908)46:2<236::AID-JBM13>3.0.CO
[19]  
2-F
[20]   A new type of ''bioartificial'' nerve graft for bridging extended defects in nerves [J].
Lundborg, G ;
Dahlin, L ;
Dohl, D ;
Kanje, M ;
Terada, N .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1997, 22B (03) :299-303