Comparison between pulsed-wave Doppler- and tissue Doppler-derived Tei indices in fetuses with and without congenital heart disease

被引:51
作者
Acharya, G. [1 ,2 ,3 ,4 ]
Pavlovic, M. [1 ,2 ,5 ]
Ewing, L. [1 ,2 ]
Nollmann, D. [1 ,2 ]
Leshko, J. [1 ,2 ]
Huhta, J. C. [1 ,2 ]
机构
[1] Univ S Florida, Coll Med, Dept Pediat, St Petersburg, FL 33701 USA
[2] Univ S Florida, All Childrens Hosp, Childrens Res Inst, St Petersburg, FL 33701 USA
[3] Univ Tromso, Fac Med, Dept Obstet & Gynecol, Tromso, Norway
[4] Univ Hosp No Norway, Tromso, Norway
[5] Univ Childrens Hosp, Div Pediat Cardiol, Bern, Switzerland
关键词
fetal cardiac function; pulsed-wave Doppler; Tei index; tissue Doppler;
D O I
10.1002/uog.5292
中图分类号
O42 [声学];
学科分类号
070206 [声学]; 082403 [水声工程];
摘要
Objectives The aim of this study was to compare the right (RV) and left (LV) ventricular Tei indices obtained by pulsed-wave Doppler (PD) and tissue Doppler (TD) methods in fetuses with structurally normal and abnormal hearts. Methods This was a retrospective cross-sectional study of 147 fetuses that had a fetal echocardiogram and Tei index measured during a 2-year period. The R V and LV Tei indices were measured using both PD and TD methods. The difference between the two methods of Tei index measurement was tested using paired sample t-test, Pearson correlation coefficient was used to examine their relationship, and the agreement between the methods was tested using Bland-Altman analysis. Results A total of 87 fetuses had normal hearts and 60 had a congenital heart defect. Both PD and TD Tei indices were measured successfully from at least one ventricle in 123 cases and from both ventricles in 110 cases. The mean TD Tei index was significantly higher than the mean PD Tei index for both ventricles (P < 0.0001). There was a weak but statistically significant correlation between the PD and TD Tei indices of the right ventricle (r = 0.20, P = 0.029), whereas the PD and TD Tei indices of the left ventricle did not correlate significantly (r = 0.04, P = 0.684). When pairs of Tei indices measured by two different methods (123 pairs for the right ventricle and 121 for the left ventricle) were tested with Bland-Altman analysis, the bias and precision were 0.147 and 0.254, respectively, for the right ventricle, and 0.299 and 0.276, respectively, for the left ventricle. Conclusions Correlation between Tei indices measured by PD and TD methods is weak and the agreement between individual measurements is poor. Therefore, they should not be used interchangeably in the assessment of fetal cardiac function. Copyright (c) 2008 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:406 / 411
页数:6
相关论文
共 28 条
[1]
The Fetal Cardiac Function [J].
Acharya, Ganesh ;
Rasanen, Juha ;
Kiserud, Torvid ;
Huhta, James C. .
CURRENT CARDIOLOGY REVIEWS, 2006, 2 (01) :41-53
[2]
Quantitative assessment of right ventricular function using Doppler tissue imaging in fetuses with and without heart failure [J].
Aoki, M ;
Harada, K ;
Ogawa, M ;
Tanaka, T .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2004, 17 (01) :28-35
[3]
Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[4]
Effects of modulation of left ventricular contractile state and loading conditions on tissue Doppler myocardial performance index [J].
Cannesson, M ;
Jacques, D ;
Pinsky, MR ;
Gorcsan, J .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2006, 290 (05) :H1952-H1959
[5]
The effects of changes in loading conditions and modulation of inotropic state on the myocardial performance index: comparison with conductance catheter measurements [J].
Cheung, MMH ;
Smallhorn, JF ;
Redington, AN ;
Vogel, M .
EUROPEAN HEART JOURNAL, 2004, 25 (24) :2238-2242
[6]
Left ventricular Tei index in children: Comparison of tissue Doppler imaging, pulsed wave Doppler, and M-mode echocardiography normal values [J].
Cui, Wei ;
Roberson, David A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (12) :1438-1445
[7]
Quantitative assessment of fetal ventricular function: Establishing normal values of the myocardial performance index in the fetus [J].
Eidem, BW ;
Edwards, JM ;
Cetta, F .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2001, 18 (01) :9-13
[8]
Fetal congestive heart failure: correlation of Tei-Index and Cardiovascular-Score [J].
Falkensammer, CB ;
Paul, J ;
Huhta, JC .
JOURNAL OF PERINATAL MEDICINE, 2001, 29 (05) :390-398
[9]
Fetal cardiac function assessed by Doppler myocardial performance index (Tei Index) [J].
Friedman, D ;
Buyon, J ;
Kim, M ;
Glickstein, JS .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 21 (01) :33-36
[10]
Left ventricle myocardial performance index derived either by conventional method or mitral annulus tissue-Doppler: A comparison study in healthy subjects and subjects with heart failure [J].
Gaibazzi, N ;
Petrucci, N ;
Ziacchi, V .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (12) :1270-1276