Closed-loop insulin delivery: from bench to clinical practice

被引:221
作者
Hovorka, Roman [1 ]
机构
[1] Univ Cambridge, Addenbrookes Hosp, Inst Metab Sci, Cambridge CB2 0QQ, England
关键词
BLOOD-GLUCOSE CONTROL; ARTIFICIAL BETA-CELL; NOCTURNAL HYPOGLYCEMIA; PSYCHOSOCIAL FACTORS; GLYCEMIC CONTROL; PUMP THERAPY; TYPE-1; CHILDREN; PANCREAS; EXERCISE;
D O I
10.1038/nrendo.2011.32
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Automated closed-loop insulin delivery, also referred to as the 'artificial pancreas', has been an important but elusive goal of diabetes treatment for many decades. Research milestones include the conception of continuous glucose monitoring in the early 1960s, followed by the production of the first commercial hospital-based artificial pancreas in the late 1970s that combined intravenous glucose sensing and insulin delivery. In the past 10 years, research into the artificial pancreas has gained substantial momentum and focused on the subcutaneous route for glucose measurement and insulin delivery, which reflects technological advances in interstitial glucose monitoring and the increasing use of the continuous subcutaneous insulin infusion. This Review discusses the design of an artificial pancreas, its components and clinical results, as well as the advantages and disadvantages of different types of automated closed-loop systems and potential future advances. The introduction of the artificial pancreas into clinical practice will probably occur gradually, starting with simpler approaches, such as overnight control of blood glucose concentration and temporary pump shut-off, that are adapted to more complex situations, such as glycemic control during meals and exercise.
引用
收藏
页码:385 / 395
页数:11
相关论文
共 119 条
[1]   ARTIFICIAL ENDOCRINE PANCREAS [J].
ALBISSER, AM ;
LEIBEL, BS ;
EWART, TG ;
DAVIDOVAC, Z ;
BOTZ, CK ;
ZINGG, W .
DIABETES, 1974, 23 (05) :389-396
[2]  
[Anonymous], ARTIFICIAL ENDOCRINE
[3]   MD-Logic Artificial Pancreas System A pilot study in adults with type 1 diabetes [J].
Atlas, Eran ;
Nimri, Revital ;
Miller, Shahar ;
Grunberg, Eli A. ;
Phillip, Moshe .
DIABETES CARE, 2010, 33 (05) :1072-1076
[4]   Effects of age and sex on postprandial glucose metabolism - Differences in glucose turnover, insulin secretion, insulin action, and hepatic insulin extraction [J].
Basu, Rita ;
Man, Chiara Dalla ;
Campioni, Marco ;
Basu, Ananda ;
Klee, George ;
Toffolo, Gianna ;
Cobelli, Claudio ;
Rizza, Robert A. .
DIABETES, 2006, 55 (07) :2001-2014
[5]   The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 Diabetes [J].
Beck, Roy W. .
DIABETES CARE, 2009, 32 (08) :1378-1383
[6]  
Bequette B Wayne, 2005, Diabetes Technol Ther, V7, P28, DOI 10.1089/dia.2005.7.28
[7]   Effectiveness of Sensor-Augmented Insulin-Pump Therapy in Type 1 Diabetes [J].
Bergenstal, Richard M. ;
Tamborlane, William V. ;
Ahmann, Andrew ;
Buse, John B. ;
Dailey, George ;
Davis, Stephen N. ;
Joyce, Carol ;
Peoples, Tim ;
Perkins, Bruce A. ;
Welsh, John B. ;
Willi, Steven M. ;
Wood, Michael A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (04) :311-320
[8]  
Breton Marc D, 2008, J Diabetes Sci Technol, V2, P169
[9]   Duration of Nocturnal Hypoglycemia Before Seizures [J].
Buckingham, Bruce ;
Wilson, Darrell M. ;
Lecher, Todd ;
Hanas, Ragnar ;
Kaiserman, Kevin ;
Cameron, Fergus .
DIABETES CARE, 2008, 31 (11) :2110-2112
[10]   Prevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension [J].
Buckingham, Bruce ;
Chase, H. Peter ;
Dassau, Eyal ;
Cobry, Erin ;
Clinton, Paula ;
Gage, Victoria ;
Caswell, Kimberly ;
Wilkinson, John ;
Cameron, Fraser ;
Lee, Hyunjin ;
Bequette, B. Wayne ;
Doyle, Francis J., III .
DIABETES CARE, 2010, 33 (05) :1013-1017