Automated closed-loop insulin delivery, also referred to as the 'artificial pancreas', has been an important but elusive goal of diabetes treatment for many decades. Research milestones include the conception of continuous glucose monitoring in the early 1960s, followed by the production of the first commercial hospital-based artificial pancreas in the late 1970s that combined intravenous glucose sensing and insulin delivery. In the past 10 years, research into the artificial pancreas has gained substantial momentum and focused on the subcutaneous route for glucose measurement and insulin delivery, which reflects technological advances in interstitial glucose monitoring and the increasing use of the continuous subcutaneous insulin infusion. This Review discusses the design of an artificial pancreas, its components and clinical results, as well as the advantages and disadvantages of different types of automated closed-loop systems and potential future advances. The introduction of the artificial pancreas into clinical practice will probably occur gradually, starting with simpler approaches, such as overnight control of blood glucose concentration and temporary pump shut-off, that are adapted to more complex situations, such as glycemic control during meals and exercise.
引用
收藏
页码:385 / 395
页数:11
相关论文
共 119 条
[71]   An improved PID switching control strategy for type 1 diabetes [J].
Marchetti, Gianni ;
Barolo, Massimiliano ;
Jovanovic, Lois ;
Zisser, Howard ;
Seborg, Dale E. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (03) :857-865
[72]   Detection of Hypoglycemia with Continuous Interstitial and Traditional Blood Glucose Monitoring Using the FreeStyle Navigator Continuous Glucose Monitoring System [J].
McGarraugh, Geoffrey ;
Bergenstal, Richard .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (03) :145-150
[73]   Glucose requirements to maintain euglycemia after moderate-intensity afternoon exercise in adolescents with type 1 diabetes are increased in a biphasic manner [J].
McMahon, Sarah K. ;
Ferreira, Luis D. ;
Ratnam, Nirubasini ;
Davey, Raymond J. ;
Youngs, Leanne M. ;
Davis, Elizabeth A. ;
Fournier, Paul A. ;
Jones, Timothy W. .
JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2007, 92 (03) :963-968
[74]   Closed-Loop Insulin Delivery During Pregnancy Complicated by Type 1 Diabetes [J].
Murphy, Helen R. ;
Eller, Daniela ;
Allen, Janet M. ;
Harris, Julie ;
Simmons, David ;
Rayman, Gerry ;
Temple, Rosemary ;
Dunger, David B. ;
Haidar, Ahmad ;
Nodale, Marianna ;
Wilinska, Malgorzata E. ;
Hovorka, Roman .
DIABETES CARE, 2011, 34 (02) :406-411
[75]   What is artificial endocrine pancreas? Mechanism and history [J].
Nishida, Kenro ;
Shimoda, Seiya ;
Ichinose, Kenshi ;
Araki, Eiichi ;
Shichiri, Motoaki .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (33) :4105-4110
[76]  
PALERM CC, 2009, J DIABETES SCI TECHN, V3, pA124
[77]   Evaluation of the effect of gain on the meal response of an automated closed-loop insulin delivery system [J].
Panteleon, Antonios E. ;
Loutseiko, Mikhail ;
Steil, Garry M. ;
Rebrin, Kerstin .
DIABETES, 2006, 55 (07) :1995-2000
[78]   A model-based algorithm for blood glucose control in type I diabetic patients [J].
Parker, RS ;
Doyle, FJ ;
Peppas, NA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1999, 46 (02) :148-157
[79]  
Patek Stephen D, 2009, J Diabetes Sci Technol, V3, P269
[80]  
Percival Matthew W, 2008, J Diabetes Sci Technol, V2, P636