Assessment of renal function using intravoxel incoherent motion diffusion-weighted imaging and dynamic contrast-enhanced MRI

被引:63
作者
Bane, Octavia [2 ]
Wagner, Mathilde [2 ]
Zhang, Jeff L. [5 ,6 ]
Dyvorne, Hadrien A. [2 ]
Orton, Matthew [7 ]
Rusinek, Henry [3 ,4 ]
Taouli, Bachir [1 ,2 ]
机构
[1] Icahn Sch Med Mt Sinai, Dept Radiol, 1 Gustave L Levy Pl,Box 1234, New York, NY 10029 USA
[2] Icahn Sch Med Mt Sinai, Translat & Mol Imaging Inst, New York, NY USA
[3] NYU, Dept Radiol, 560 1St Ave, New York, NY 10016 USA
[4] NYU, Dept Biomed Engn, New York, NY USA
[5] Univ Utah, Dept Radiol, Salt Lake City, UT 84132 USA
[6] Univ Utah, Dept Biomed Engn, Salt Lake City, UT USA
[7] Inst Canc Res, Div Radiotherapy & Imaging, Sutton, Surrey, England
关键词
renal DCE-MRI; renal DWI-MRI; IVIM; renal function in liver disease; GLOMERULAR-FILTRATION-RATE; MAGNETIC-RESONANCE; RENOGRAPHY; KIDNEY; PERFUSION; REPRODUCIBILITY; LIVER; MODEL; ACQUISITION; DYSFUNCTION;
D O I
10.1002/jmri.25171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
PurposeTo assess the correlation between each of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) metrics in renal parenchyma with renal function, in a cohort of patients with chronic liver disease. Materials and MethodsThirty patients with liver disease underwent abdominal MRI at 1.5T, including a coronal respiratory-triggered IVIM-DWI sequence and a coronal 3D FLASH DCE-MRI acquisition. Diffusion signals in the renal cortex and medulla were fitted to the IVIM model to estimate the diffusion coefficient (D), pseudodiffusion coefficient (D*), and perfusion fraction (PF). The apparent diffusion coefficient (ADC) was calculated using all b-values. The glomerular filtration rate (GFR), cortical and medullary renal plasma flow (RPF), mean transit times (MTT) of vascular and tubular compartments and the whole kidney, were calculated from DCE-MRI data by fitting to a three-compartment model. The estimated GFR (eGFR) was calculated from serum creatinine measured 3027 days of MRI. ResultsADC, PF, and RPF were significantly higher in renal cortex vs. medulla (P < 10(-5)). DCE-MRI GFR significantly correlated with, but underestimated, eGFR (Spearman's r/P=0.49/0.01). IVIM-DWI parameters were not significantly correlated with eGFR. DCE-MRI GFR correlated weakly with D (cortex, r/P=0.3/0.03; medulla r/P=0.27/0.05) and ADC (cortex r/P=0.28/0.04; medulla r/P=0.34/0.01). Weak correlations were observed for pooled cortical and medullar RPF with PF (r/P=0.32/10(-3)) and with ADC (r/P=0.29/0.0025). Significant negative correlations were observed for vascular MTT with cortical D* (r/P=-0.38/0.004) and D*xPF (r/P=-0.34/0.01). ConclusionThe weak correlations between renal IVIM and DCE-MRI perfusion parameters imply that these functional measures could be complementary. J. Magn. Reson. Imaging 2016;44:317-326.
引用
收藏
页码:317 / 326
页数:10
相关论文
共 29 条
[1]
Measurement reproducibility of perfusion fraction and pseudodiffusion coefficient derived by intravoxel incoherent motion diffusion-weighted MR imaging in normal liver and metastases [J].
Andreou, A. ;
Koh, D. M. ;
Collins, D. J. ;
Blackledge, M. ;
Wallace, T. ;
Leach, M. O. ;
Orton, M. R. .
EUROPEAN RADIOLOGY, 2013, 23 (02) :428-434
[2]
Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney [J].
Annet, L ;
Hermoye, L ;
Peeters, F ;
Jamar, F ;
Dehoux, JP ;
Van Beers, BE .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :843-849
[3]
[Anonymous], MAGN RESON MED
[4]
DCE-MRI of the Liver: Effect of Linear and Nonlinear Conversions on Hepatic Perfusion Quantification and Reproducibility [J].
Aronhime, Shimon ;
Calcagno, Claudia ;
Jajamovich, Guido H. ;
Dyvorne, Hadrien Arezki ;
Robson, Philip ;
Dieterich, Douglas ;
Fiel, M. Isabel ;
Martel-Laferriere, Valerie ;
Chatterji, Manjil ;
Rusinek, Henry ;
Taouli, Bachir .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 40 (01) :90-98
[5]
Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI [J].
Baumann, D ;
Rudin, M .
MAGNETIC RESONANCE IMAGING, 2000, 18 (05) :587-595
[6]
An algorithm for the grading of activity in chronic hepatitis C [J].
Bedossa, P ;
Poynard, T .
HEPATOLOGY, 1996, 24 (02) :289-293
[7]
Quality Assurance Multicenter Comparison of Different MR Scanners for Quantitative Diffusion-Weighted Imaging [J].
Belli, Giacomo ;
Busoni, Simone ;
Ciccarone, Antonio ;
Coniglio, Angela ;
Esposito, Marco ;
Giannelli, Marco ;
Mazzoni, Lorenzo N. ;
Nocetti, Luca ;
Sghedoni, Roberto ;
Tarducci, Roberto ;
Zatelli, Giovanna ;
Anoja, Rosa A. ;
Belmonte, Gina ;
Bertolino, Nicola ;
Betti, Margherita ;
Biagini, Cristiano ;
Ciarmatori, Alberto ;
Cretti, Fabiola ;
Fabbri, Emma ;
Fedeli, Luca ;
Filice, Silvano ;
Fulcheri, Christian P. L. ;
Gasperi, Chiara ;
Mangili, Paola A. ;
Mazzocchi, Silvia ;
Meliado, Gabriele ;
Morzenti, Sabrina ;
Noferini, Linhsia ;
Oberhofer, Nadia ;
Orsingher, Laura ;
Paruccini, Nicoletta ;
Princigalli, Goffredo ;
Quattrocchi, Mariagrazia ;
Rinaldi, Adele ;
Scelfo, Danilo ;
Freixas, Gloria Vilches ;
Tenori, Leonardo ;
Zucca, Ileana ;
Luchinat, Claudio ;
Gori, Cesare ;
Gobbi, Gianni .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) :213-219
[8]
Estimates of Glomerular Filtration Rate From MR Renography and Tracer Kinetic Models [J].
Bokacheva, Louisa ;
Rusinek, Henry ;
Zhang, Jeff L. ;
Chen, Qun ;
Lee, Vivian S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) :371-382
[9]
Nonalcoholic Fatty Liver Disease (NAFLD) Activity Score and the Histopathologic Diagnosis in NAFLD: Distinct Clinicopathologic Meanings [J].
Brunt, Elizabeth M. ;
Kleiner, David E. ;
Wilson, Laura A. ;
Belt, Patricia ;
Neuschwander-Tetri, Brent A. .
HEPATOLOGY, 2011, 53 (03) :810-820
[10]
Diffusion-weighted Imaging of the Liver with Multiple b Values: Effect of Diffusion Gradient Polarity and Breathing Acquisition on Image Quality and Intravoxel Incoherent Motion Parameters-A Pilot Study [J].
Dyvorne, Hadrien A. ;
Galea, Nicola ;
Nevers, Thomas ;
Fiel, M. Isabel ;
Carpenter, David ;
Wong, Edmund ;
Orton, Matthew ;
de Oliveira, Andre ;
Feiweier, Thorsten ;
Vachon, Marie-Louise ;
Babb, James S. ;
Taouli, Bachir .
RADIOLOGY, 2013, 266 (03) :920-929