Tumour delineation and cumulative dose computation in radiotherapy based on deformable registration of respiratory correlated CT images of lung cancer patients

被引:58
作者
de Xivry, Jonathan Orban [1 ,2 ]
Janssens, Guillaume [1 ,2 ]
Bosmans, Geert [2 ]
De Craene, Mathieu [1 ]
Dekker, Andre [2 ]
Buijsen, Jeroen [2 ]
van Baardwijk, Angela [2 ]
De Ruysscher, Dirk [2 ]
Macq, Benoit [1 ]
Lambin, Philippe [2 ]
机构
[1] Catholic Univ Louvain, Commun & Remote Sensing Lab TELE, B-1348 Louvain, Belgium
[2] GROW, Dept Radiat Oncol MAASTRO, Maastricht, Netherlands
关键词
RC-CT; deformation; b-spline registration; delineation; dose distribution;
D O I
10.1016/j.radonc.2007.08.012
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To improve treatment planning in radiotherapy for non-small cell lung cancer by including Respiratory Correlated-Computed Tomography (RC-CT) information in tumour delineation and dose planning. Methods and materials: Dense displacement fields were computed using a combination of rigid and non-rigid registrations between RC-CT phases. These registrations have been performed independently between each phase of the respiratory cycle and a reference phase for 13 patients. A manual delineation in the reference frame was propagated to every other phase according to the deformation fields recovered from the inter-phase registrations. Resulting delineations were compared to two manual delineations drawn by two physicians at each phase. On the other hand, dose distributions computed for every phase were deformed towards the reference phase. These distributions were then added on the reference phase to estimate the total dose received by each voxel through the whole respiratory cycle. Results: The overlap between the deformed and the manual delineations was not significantly different than the overlap between the delineations made by the two physicians for 11 out of 13 patients thus proving that the method accuracy is comparable to inter-observer variability. Calculation of the effective dose distributions showed that these were conserved after deformation. Conclusion: We developed a method to use RC-CT information into the radiation treatment planning, including semiautomatic segmentation of lung tumours on each phase of the respiratory cycle and a total received dose per voxel estimation. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 27 条
[1]   An "in silico" clinical trial comparing free breathing, slow and respiration correlated computed tomography in lung cancer patients [J].
Bosmans, Geert ;
Buijsen, Jeroen ;
Dekker, Andre ;
Velders, Marije ;
Boersma, Liesbeth ;
De Ruysscher, Dirk ;
Minken, Andre ;
Lambin, Philippe .
RADIOTHERAPY AND ONCOLOGY, 2006, 81 (01) :73-80
[2]   Intra-patient variability of tumor volume and tumor motion during conventionally fractionated radiotherapy for locally advanced non-small-cell lung cancer:: A prospective clinical study [J].
Bosmans, Geert ;
van Baardwijk, Angela ;
Dekker, Andre ;
Ollers, Michel ;
Boersma, Liesbeth ;
Minken, Andre ;
Lambin, Philippe ;
De Ruysscher, Dirk .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03) :748-753
[3]   The susceptibility of IMRT dose distributions to intrafraction organ motion: An investigation into smoothing filters derived from four dimensional computed tomography data [J].
Coolens, Catherine ;
Evans, Phil M. ;
Seco, Joao ;
Webb, Steve ;
Blackall, Jane M. ;
Rietzel, Eike ;
Chen, George T. Y. .
MEDICAL PHYSICS, 2006, 33 (08) :2809-2818
[4]   Tumor location cannot predict the mobility of lung tumors: A 3D analysis of data generated from multiple CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Nijssen-Visser, MRJ ;
Graveland, WJ ;
Senan, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 56 (02) :348-354
[5]   Four-dimensional proton treatment planning for lung tumors [J].
Engelsman, M ;
Rietzel, E ;
Kooy, HM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05) :1589-1595
[6]   The effect of breathing and set-up errors on the cumulative dose to a lung tumor [J].
Engelsmann, M ;
Damen, EMF ;
De Jaeger, K ;
van Ingen, KM ;
Mijnheer, BJ .
RADIOTHERAPY AND ONCOLOGY, 2001, 60 (01) :95-105
[7]   Respiration-correlated spiral CT: A method of measuring respiratory-induced anatomic motion for radiation treatment planning [J].
Ford, EC ;
Mageras, GS ;
Yorke, E ;
Ling, CC .
MEDICAL PHYSICS, 2003, 30 (01) :88-97
[8]   A direct voxel tracking method for four-dimensional Monte Carlo dose calculations in deforming anatomy [J].
Heath, E ;
Seuntjens, J .
MEDICAL PHYSICS, 2006, 33 (02) :434-445
[9]  
Ibanez L, 2005, ITK SOFTWARE GUIDE
[10]  
International Commission in Radiation Units and Measurements, 1999, 62 ICRU