Real-time Control of Angioplasty Balloon Inflation Based on Feedback from Intravascular Optical Coherence Tomography: Experimental Validation on an Excised Heart and a Beating Heart Model

被引:4
作者
Azarnoush, Hamed [1 ,2 ]
Vergnole, Sebastien [1 ]
Boulet, Benoit [2 ]
Sowa, Michael [3 ]
Lamouche, Guy [1 ]
机构
[1] Natl Res Council Canada, Inst Ind Mat, Boucherville, PQ J4B 6Y4, Canada
[2] McGill Univ, Ctr Intelligent Machines, Montreal, PQ H3A 2A7, Canada
[3] Natl Res Council Canada, Inst Biodiagnost, Winnipeg, MB R3B 1Y6, Canada
关键词
Angioplasty; control; optical coherence tomography; real-time systems; CORONARY ANGIOPLASTY; ULTRASOUND; ANGIOGRAPHY;
D O I
10.1109/TBME.2012.2189884
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We report on real-time control of balloon inflation inside porcine arteries. In the first step, experiments were done in a coronary artery of an excised heart. In the second step, experiments were done in a beating heart setup providing conditions very close to in vivo conditions without the complications. A programmable syringe pump was used to inflate a compliant balloon in arteries, while intravascular optical coherence tomography (IVOCT) monitoring was performed. In a feedback loop, IVOCT images were processed to provide the balloon diameter values in real time to control the pump action in order to achieve a target diameter. In different experiments, various flow rates and target diameters were used. In the excised heart experiment, there was good convergence to target diameters resulting in a satisfactory balloon inflation control. In the beating heart experiment, there were oscillations in the diameter values due to cyclic arterial contractions. In these experiments, the control system maintained diameter averages satisfactorily close to predetermined target values. Real-time control of balloon inflation could not only provide a safer outcome for angioplasty procedures, but could also provide additional information for diagnostics since it implicitly provides information about the artery response to the inflation process.
引用
收藏
页码:1488 / 1495
页数:8
相关论文
共 19 条
[1]   Real-Time Control of Angioplasty Balloon Inflation Based on Feedback From Intravascular Optical Coherence Tomography: Preliminary Study on an Artery Phantom [J].
Azarnoush, Hamed ;
Vergnole, Sebastien ;
Boulet, Benoit ;
DiRaddo, Robert ;
Lamouche, Guy .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (03) :697-705
[2]   Artery phantoms for intravascular optical coherence tomography: healthy arteries [J].
Bisaillon, Charles-Etienne ;
Dufour, Marc L. ;
Lamouche, Guy .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (09) :2599-2613
[3]  
Blasini R, 1997, CATHETER CARDIO DIAG, V42, P113, DOI 10.1002/(SICI)1097-0304(199710)42:2<113::AID-CCD2>3.0.CO
[4]  
2-G
[5]   Evaluation of intracoronary stenting by intravascular optical coherence tomography [J].
Bouma, BE ;
Tearney, GJ ;
Yabushita, H ;
Shishkov, M ;
Kauffman, CR ;
Gauthier, DD ;
MacNeill, BD ;
Houser, SL ;
Aretz, HT ;
Halpern, EF ;
Jang, IK .
HEART, 2003, 89 (03) :317-320
[6]   Discrepancy between angiography and intravascular ultrasound when analysing small coronary arteries [J].
Briguori, C ;
Tobis, J ;
Nishida, T ;
Vaghetti, M ;
Albiero, R ;
Di Mario, C ;
Colombo, A .
EUROPEAN HEART JOURNAL, 2002, 23 (03) :247-254
[7]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[8]  
Dorf R. C., 2008, Modern Control Systems
[9]  
Faxon D.P., 2001, Restenosis: A Guide To Therapy
[10]   CORONARY ANGIOPLASTY WITH GRADUAL VERSUS RAPID BALLOON INFLATION - INITIAL RESULTS AND COMPLICATIONS [J].
ILIA, R ;
CABIN, H ;
MCCONNELL, S ;
CLEMAN, M ;
REMETZ, M .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 29 (03) :199-202