Artery phantoms for intravascular optical coherence tomography: healthy arteries

被引:24
作者
Bisaillon, Charles-Etienne [1 ]
Dufour, Marc L. [1 ]
Lamouche, Guy [1 ]
机构
[1] Conseil Natl Rech Canada, Inst Ind Mat, Boucherville, PQ J4B 6Y4, Canada
来源
BIOMEDICAL OPTICS EXPRESS | 2011年 / 2卷 / 09期
关键词
CONTRAST; TISSUE;
D O I
10.1364/BOE.2.002599
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a method to make phantoms of coronary arteries for intravascular optical coherence tomography (IV-OCT). The phantoms provide a calibrated OCT response similar to the layered structure of arteries. The optical properties of each layer are achieved with specific concentrations of alumina and carbon black in a silicone matrix. This composition insures high durability and also approximates the elastic properties of arteries. The phantoms are fabricated in a tubular shape by the successive deposition and curing of liquid silicone mixtures on a lathe setup. (C) 2011 Optical Society of America
引用
收藏
页码:2599 / 2613
页数:15
相关论文
共 17 条
[1]   Three-dimensional characterization of optical coherence tomography point spread functions with a nanoparticle-embedded phantom [J].
Agrawal, Anant ;
Pfefer, T. Joshua ;
Gilani, Naureen ;
Drezek, Rebekah .
OPTICS LETTERS, 2010, 35 (13) :2269-2271
[2]   Deformable and durable phantoms with controlled density of scatterers [J].
Bisaillon, Charles-Etienne ;
Lamouche, Guy ;
Maciejko, Romain ;
Dufour, Marc ;
Monchalin, Jean-Pierre .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :N237-N247
[3]   Optical phantoms of varying geometry based on thin building blocks with controlled optical properties [J].
de Bruin, Daniel M. ;
Bremmer, Rolf H. ;
Kodach, Vitali M. ;
de Kinkelder, Roy ;
van Marle, Jan ;
van Leeuwen, Ton G. ;
Faber, Dirk J. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (02)
[4]  
Goodman J. W., 2007, Speckle phenomena in optics: theory and applications
[5]   Elastographic contrast generation in optical coherence tomography from a localized shear stress [J].
Grimwood, Alex ;
Garcia, Leo ;
Bamber, Jeff ;
Holmes, Jon ;
Woolliams, Peter ;
Tomlins, Pete ;
Pankhurst, Quentin A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (18) :5515-5528
[6]   Near-infrared breast tomography calibration with optoelastic tissue simulating phantoms [J].
Jiang, SD ;
Pogue, BW ;
McBride, TO ;
Doyley, MM ;
Poplack, SP ;
Paulsen, KD .
JOURNAL OF ELECTRONIC IMAGING, 2003, 12 (04) :613-620
[7]   Fibrin phantom for use in optical coherence tomography [J].
Kennedy, Brendan F. ;
Loitsch, Susanne ;
McLaughlin, Robert A. ;
Scolaro, Loretta ;
Rigby, Paul ;
Sampson, David D. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (03)
[8]   Optical delay line using rotating rhombic prisms [J].
Lamouche, G. ;
Dufour, M. ;
Gauthier, B. ;
Bartulovic, V. ;
Hewko, M. ;
Monchalin, J. -P. .
COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
[9]   Intravascular optical coherence tomography on a beating heart model [J].
Lamouche, Guy ;
Dufour, Marc ;
Hewko, Mark ;
Vergnole, Sebastien ;
Gauthier, Bruno ;
Bisaillon, Charles-Etienne ;
Monchalin, Jean-Pierre ;
Sowa, Michael G. .
JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (04)
[10]   The Need for Validation Standards in Medical Imaging [J].
Nordstrom, Robert J. .
DESIGN AND PERFORMANCE VALIDATION OF PHANTOMS USED IN CONJUNCTION WITH OPTICAL MEASUREMENT OF TISSUE II, 2010, 7567