Fibrin phantom for use in optical coherence tomography

被引:29
作者
Kennedy, Brendan F. [1 ]
Loitsch, Susanne [1 ]
McLaughlin, Robert A. [1 ]
Scolaro, Loretta [1 ]
Rigby, Paul [2 ]
Sampson, David D. [1 ,2 ]
机构
[1] Univ Western Australia, Sch Elect Elect & Comp Engn, Opt Biomed Engn Lab, Crawley, WA 6009, Australia
[2] Univ Western Australia, Ctr Microscopy Characterisat & Anal, Crawley, WA 6009, Australia
关键词
Fibrin; optical coherence tomography; tissue-mimicking phantom; ATTENUATION; SCATTERING;
D O I
10.1117/1.3427249
中图分类号
Q5 [生物化学];
学科分类号
070307 [化学生物学];
摘要
This work presents a novel tissue-mimicking phantom for use in a range of optical coherence tomography (OCT) experiments. Such phantoms are critical in the development and assessment of new OCT techniques, but no previously published phantoms have become universally accepted. We present the first description of a phantom based on a fibrin matrix, which improves key attributes of previously published methods. It provides a biocompatible, optically transparent scaffold in which to incorporate organic and/or inorganic optical scattering materials. Its fabrication time is markedly shorter than many common phantoms, and its lifetime is longer than other biocompatible phantoms. The potential of fibrin phantoms incorporating Intralipid (TM) to introduce uniform optical scattering is demonstrated. The measured attenuation coefficient as a function of Intralipid concentration confirms the ability to control optical scattering. A bilayer phantom with distinct optical scattering in each layer is also presented. (C) 2010 Society of Photo-Optical Instrumentation Engineers. [DOI: 10.1117/1.3427249]
引用
收藏
页数:3
相关论文
共 12 条
[1]
[Anonymous], 2007, TISSUE OPTICS LIGHT, DOI DOI 10.1117/3.684093
[2]
Deformable and durable phantoms with controlled density of scatterers [J].
Bisaillon, Charles-Etienne ;
Lamouche, Guy ;
Maciejko, Romain ;
Dufour, Marc ;
Monchalin, Jean-Pierre .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (13) :N237-N247
[3]
Design, fabrication, and characterization of a tissue-equivalent phantom for optical elastography [J].
Devi, CU ;
Vasu, RM ;
Sood, AK .
JOURNAL OF BIOMEDICAL OPTICS, 2005, 10 (04)
[4]
Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography [J].
Faber, DJ ;
van der Meer, FJ ;
Aalders, MCG ;
van Leeuwen, TG .
OPTICS EXPRESS, 2004, 12 (19) :4353-4365
[5]
Feldman Dale S., 1995, P1347
[6]
Increased effectiveness of fibrin sealant with a higher fibrin concentration [J].
Kaetsu, H ;
Uchida, T ;
Shinya, N .
INTERNATIONAL JOURNAL OF ADHESION AND ADHESIVES, 2000, 20 (01) :27-31
[7]
In vivo dynamic optical coherence elastography using a ring actuator [J].
Kennedy, Brendan F. ;
Hillman, Timothy R. ;
McLaughlin, Robert A. ;
Quirk, Bryden C. ;
Sampson, David D. .
OPTICS EXPRESS, 2009, 17 (24) :21762-21772
[8]
Imaging needle for optical coherence tomography [J].
Li, XD ;
Chudoba, C ;
Ko, T ;
Pitris, C ;
Fujimoto, JG .
OPTICS LETTERS, 2000, 25 (20) :1520-1522
[9]
McLaughlin RA, 2009, LECT NOTES COMPUT SC, V5762, P657, DOI 10.1007/978-3-642-04271-3_80
[10]
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry [J].
Pogue, Brian W. ;
Patterson, Michael S. .
JOURNAL OF BIOMEDICAL OPTICS, 2006, 11 (04)