Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography

被引:262
作者
Faber, DJ
van der Meer, FJ
Aalders, MCG
van Leeuwen, TG
机构
[1] Univ Amsterdam, Acad Med Ctr, Ctr Laser, NL-1100 DE Amsterdam, Netherlands
[2] Univ Twente, Biomed Technol Inst, NL-7500 AE Enschede, Netherlands
来源
OPTICS EXPRESS | 2004年 / 12卷 / 19期
关键词
D O I
10.1364/OPEX.12.004353
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
From calibrated, weakly scattering tissue phantoms (2-6 mm(-1)), we extract the attenuation coefficient with an accuracy of 0.8 mm(-1) from OCT data in the clinically relevant 'fixed focus' geometry. The data are analyzed using a single scattering model and a recently developed description of the confocal point spread function (PSF). We verify the validity of the single scattering model by a quantitative comparison with a multiple scattering model, and validate the use of the PSF on the calibrated samples. Implementation of this model for existing OCT systems will be straightforward. Localized quantitative measurement of the attenuation coefficient of different tissues can significantly improve the clinical value of OCT. (C) 2004 Optical Society of America.
引用
收藏
页码:4353 / 4365
页数:13
相关论文
共 18 条
[1]  
Altman DG, 1990, PRACTICAL STAT MED R
[2]   Noninvasive monitoring of glucose concentration with optical coherence tomography [J].
Esenaliev, RO ;
Larin, KV ;
Larina, IV ;
Motamedi, M .
OPTICS LETTERS, 2001, 26 (13) :992-994
[3]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[4]   OPTICAL COHERENCE MICROSCOPY IN SCATTERING MEDIA [J].
IZATT, JA ;
HEE, MR ;
OWEN, GM ;
SWANSON, EA ;
FUJIMOTO, JG .
OPTICS LETTERS, 1994, 19 (08) :590-592
[5]   Precision of measurement of tissue optical properties with optical coherence tomography [J].
Kholodnykh, AI ;
Petrova, IY ;
Larin, KV ;
Motamedi, M ;
Esenaliev, RO .
APPLIED OPTICS, 2003, 42 (16) :3027-3037
[6]   Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography [J].
Kholodnykh, AI ;
Petrova, IY ;
Motamedi, M ;
Esenaliev, RO .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (02) :210-221
[7]   New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography [J].
Knüttel, A ;
Bonev, S ;
Knaak, W .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (02) :265-273
[8]   Determination of optical scattering properties of highly-scattering media in optical coherence tomography images [J].
Levitz, D ;
Thrane, L ;
Frosz, MH ;
Andersen, PE ;
Andersen, CB ;
Valanciunaite, J ;
Swartling, J ;
Andersson-Engels, S ;
Hansen, PR .
OPTICS EXPRESS, 2004, 12 (02) :249-259
[9]   REFLECTION AND REFRACTION OF GAUSSIAN LIGHT BEAMS AT TILTED ELLIPSOIDAL SURFACES [J].
MASSEY, GA ;
SIEGMAN, AE .
APPLIED OPTICS, 1969, 8 (05) :975-&
[10]   In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography [J].
Nassif, N ;
Cense, B ;
Park, BH ;
Yun, SH ;
Chen, TC ;
Bouma, BE ;
Tearney, GJ ;
de Boer, JF .
OPTICS LETTERS, 2004, 29 (05) :480-482