Improved separation efficiency of neurotransmitters on a native printed capillary electrophoresis microchip simply by manipulating electroosmotic flow

被引:22
作者
Yu, Hui [1 ]
He, Feng-Yun [2 ]
Lu, Yu [1 ]
Hu, Yu-Lin [1 ]
Zhong, Hai-Yan [1 ]
Xia, Xing-Hua [1 ]
机构
[1] Nanjing Univ, Sch Chem & Chem Engn, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
[2] Nanjing Xiaozhuang Univ, Dept Chem, Nanjing 210017, Peoples R China
基金
中国国家自然科学基金;
关键词
microfluidics; printed microchip; pH; dopamine; epinephrine; electrochemical detection;
D O I
10.1016/j.talanta.2007.10.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separation and determination of dopamine and epinephrine with end-channel electrochemical (EC) detection integrated on a native printed microchip capillary electrophoresis (CE) system was investigated. Factors influencing the separation and detection were investigated and optimized. Results show manipulating EOF, which can be easily achieved by adjusting buffer pH, is a simple and effective way to achieve the baseline separation of dopamine and epinephrine in native polymeric microchips. Without surface modification of microchannel, printed microchips with advantages of low cost and easy preparation can achieve high performance like other microfluidic devices. (C) 2008 Published by Elsevier B.V.
引用
收藏
页码:43 / 48
页数:6
相关论文
共 33 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]  
Becker H, 2000, ELECTROPHORESIS, V21, P12, DOI 10.1002/(SICI)1522-2683(20000101)21:1<12::AID-ELPS12>3.0.CO
[3]  
2-7
[4]   Polymer microfluidic devices [J].
Becker, H ;
Locascio, LE .
TALANTA, 2002, 56 (02) :267-287
[5]   Electrophoresis microchip fabricated by a direct-printing process with end-channel amperometric detection [J].
Coltro, WKT ;
da Silva, JAF ;
da Silva, HDT ;
Richter, EM ;
Furlan, R ;
Angnes, L ;
do Lago, CL ;
Mazo, LH ;
Carrilho, E .
ELECTROPHORESIS, 2004, 25 (21-22) :3832-3839
[6]  
DENG YZ, 1996, HIGH PERFORMANCE CAP, P35
[7]  
Edwards TL, 2002, SENSOR MATER, V14, P167
[8]   Electrokinetic control of fluid in plastified laser-printed poly(ethylene terephthalate)-toner microchips [J].
He, FY ;
Liu, AL ;
Yuan, JH ;
Coltro, WKT ;
Carrilho, E ;
Xia, XH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (01) :192-197
[9]   Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate [J].
He, FY ;
Liu, AL ;
Xia, XH .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (7-8) :1062-1067
[10]   CURRENT-MONITORING METHOD FOR MEASURING THE ELECTROOSMOTIC FLOW-RATE IN CAPILLARY ZONE ELECTROPHORESIS [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (17) :1837-1838