Benefit of time-of-flight in PET: Experimental and clinical results

被引:478
作者
Karp, Joel S. [1 ]
Surti, Sulernan [1 ]
Daube-Witherspoon, Margaret E. [1 ]
Muehllehner, Gerd [1 ]
机构
[1] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
关键词
PET; TOF PET; fully-3-dimensional whole-body imaging;
D O I
10.2967/jnumed.107.044834
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Significant improvements have made it possible to add the technology of time-of-flight (TOF) to improve PET, particularly for oncology applications. The goals of this work were to investigate the benefits of TOF in experimental phantoms and to determine how these benefits translate into improved performance for patient imaging. Methods: In this study we used a fully 3-dimensional scanner with the scintillator lutetium-yttrium oxyorthosilicate and a system timing resolution of similar to 600 ps. The data are acquired in list-mode and reconstructed with a maximum-likelihood expectation maximization algorithm; the system model includes the TOF kernel and corrections for attenuation, detector normalization, randoms, and scatter. The scatter correction is an extension of the model-based single-scatter simulation to include the time domain. Phantom measurements to study the benefit of TOF include 27-cm- and 35-cm-diameter distributions with spheres ranging in size from 10 to 37 mm. To assess the benefit of TOF PET for clinical imaging, patient studies are quantitatively analyzed. Results: The lesion phantom studies demonstrate the improved contrast of the smallest spheres with TOF compared with non-TOF and also confirm the faster convergence of contrast with TOF. These gains are evident from visual inspection of the images as well as a quantitative evaluation of contrast recovery of the spheres and noise in the background. The gains with TOF are higher for larger objects. These results correlate with patient studies in which lesions are seen more clearly and with higher uptake at comparable noise for TOF than with non-TOF Conclusion: TOF leads to a better contrast-versus-noise trade-off than non-TOF but one that is difficult to quantify in terms of a simple sensitivity gain improvement: A single gain factor for TOF improvement does not include the increased rate of convergence with TOF nor does it consider that TOF may converge to a different contrast than non-TOF. The experimental phantom results agree with those of prior simulations and help explain the improved image quality with TOF for patient oncology studies.
引用
收藏
页码:462 / 470
页数:9
相关论文
共 39 条
[1]
Optimization of a fully 3D single scatter simulation algorithm for 3D PET [J].
Accorsi, R ;
Adam, LE ;
Werner, ME ;
Karp, JS .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12) :2577-2598
[2]
ALLEMAND R, 1980, J NUCL MED, V21, P153
[3]
ANGER HO, 1966, ISA T, V5, P311
[4]
Brownell G. L., 1969, MED RADIOISOTOPE SCI, V1, P163
[5]
INSTRUMENTATION TRENDS IN NUCLEAR-MEDICINE [J].
BUDINGER, TF .
SEMINARS IN NUCLEAR MEDICINE, 1977, 7 (04) :285-297
[6]
BUDINGER TF, 1983, J NUCL MED, V24, P73
[7]
CASEY M, 2006, J NUCL MED S, V47
[8]
First experimental results of time-of-flight reconstruction on an LSO PET scanner [J].
Conti, M ;
Bendriem, B ;
Casey, M ;
Chen, M ;
Kehren, F ;
Michel, C ;
Panin, V .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4507-4526
[9]
Daube-Witherspoon ME, 2002, J NUCL MED, V43, P1398
[10]
DAUBEWITHERSPOO.ME, 2006, 2006 IEEE NUCL SCI S