Capsular replacement with synthetic mesh - Effectiveness in preventing postoperative dislocation after wide resection of proximal femoral tumors and prosthetic reconstruction

被引:35
作者
Masterson, EL [1 ]
Ferracini, R [1 ]
Griffin, AM [1 ]
Wunder, JS [1 ]
Bell, RS [1 ]
机构
[1] Univ Toronto, Mt Sinai Hosp, Musculoskeletal Oncol Unit, Toronto, ON M5G 1X5, Canada
关键词
proximal femoral replacement; postoperative dislocation; capsular repair; bone neoplasm; sarcoma; osteosarcoma; Ewing's sarcoma; chondrosarcoma; hip; arthroplasty; arthroplasty design;
D O I
10.1016/S0883-5403(98)90190-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We describe a surgical technique for replacing the hip joint capsule using synthetic mesh after oncological resections of the proximal femur that resulted in gross intraoperative instability of the prosthetic reconstruction. The results of its use in 13 patients, 6 of whom also had pelvic resections, are described. These patients were selected from a total group of 88 patients undergoing proximal femoral replacement, 75 of whom did not require capsular replacement (none of these 75 patients have experienced dislocation). In the group requiring capsular reconstruction, 1 of 4 patients with bipolar hemiarthroplasty and 4 of 9 patients with total hip replacements experienced dislocation after operation. Of the dislocated total hip replacements, 1 remains chronically dislocated, and 3 were successfully stabilized by open reduction with further capsular augmentation. Given that the resections involved removal of most of the soft tissues stabilizing the hip joint, we believe that the technique of capsular reconstruction is useful in this difficult group of patients.
引用
收藏
页码:860 / 866
页数:7
相关论文
共 23 条
[1]  
ABOULAFIA AJ, 1995, CLIN ORTHOP RELAT R, P203
[2]  
BELL RS, 1990, J ARTHROPLASTY, V5, pS25
[3]   CHEST-WALL RECONSTRUCTION FOLLOWING RESECTION OF LARGE PRIMARY MALIGNANT-TUMORS [J].
CHAPELIER, A ;
MACCHIARINI, P ;
RIETJENS, M ;
LENOT, B ;
MARGULIS, A ;
PETIT, JY ;
DARTEVELLE, P .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1994, 8 (07) :351-357
[4]   CHARACTERIZATION OF MORPHOLOGIC AND MECHANICAL-PROPERTIES OF SURGICAL MESH FABRICS [J].
CHU, CC ;
WELCH, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1985, 19 (08) :903-916
[5]  
GITELIS S, 1991, CLIN ORTHOP RELAT R, P197
[6]  
HAENTJENS P, 1994, REV CHIR ORTHOP, V80, P493
[7]  
Hejna MJ, 1997, SEMIN SURG ONCOL, V13, P18, DOI 10.1002/(SICI)1098-2388(199701/02)13:1<18::AID-SSU4>3.0.CO
[8]  
2-7
[9]   RISKS AND BENEFITS OF USING MARLEX MESH IN CHEST-WALL RECONSTRUCTION [J].
KROLL, SS ;
WALSH, G ;
RYAN, B ;
KING, RC .
ANNALS OF PLASTIC SURGERY, 1993, 31 (04) :303-306
[10]   USE OF MARLEX MESH IN THE REPAIR OF RECURRENT INCISIONAL HERNIA [J].
LIAKAKOS, T ;
KARANIKAS, I ;
PANAGIOTIDIS, H ;
DENDRINOS, S .
BRITISH JOURNAL OF SURGERY, 1994, 81 (02) :248-249