Simultaneous optimization of the resolution and analysis time in micellar liquid chromatography of phenyl thiohydantoin amino acids using Derringer's desirability function

被引:59
作者
Safa, F [1 ]
Hadjmohammadi, MR [1 ]
机构
[1] Mazandaran Univ, Dept Chem, Babol Sar, Iran
关键词
phenyl thiohydantoin amino acids; micellar liquid chromatography; optimization; Derringer's desirability function; modeling;
D O I
10.1016/j.chroma.2005.04.081
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The chemometrics approach was applied for simultaneous optimization of resolution and analysis time of nine phenyl thiohydantoin amino acids in micellar liquid chromatography. Derringer's desirability function, a multi-criteria decision making method, was tested for the evaluation of the two different chromatographic performance goals. The effect of five experimental parameters on a chromatographic response function formed using two sigmoidal desirability functions was investigated. The sigmoidal functions were used to transform the optimization criteria, resolution and analysis time, into the desirability values. The factors studied were the concentration of sodium dodecyl sulfate, alkyl chain length of the alcohol used as the organic modifier, organic modifier content, mobile phase pH and temperature. The experiments were performed according to a face-centred cube response surface experimental design to map the chromatographic response surface. Then, calculated chromatographic response functions were fitted to a polynomial model. The obtained regression model was characterized by both descriptive and predictive ability (R-2 = 0.988 and R-2 = 0.973). The model was verified, as good agreement was observed between the predicted and experimental values of the chromatographic response function in the optimal condition. Based on the results of the study, combination of response surface mapping with Derringer's desirability function allows to predict the best operating condition in micellar liquid chromatography of phenyl thiohydantoin amino acids with respect to resolution and analysis time. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 1988, Journal of Chemometrics
[2]   PARTITIONING BEHAVIOR OF SOLUTES ELUTED WITH MICELLAR MOBILE PHASES IN LIQUID-CHROMATOGRAPHY [J].
ARMSTRONG, DW ;
NOME, F .
ANALYTICAL CHEMISTRY, 1981, 53 (11) :1662-1666
[3]   UNATTENDED OPTIMIZATION OF REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATIONS USING THE MODIFIED SIMPLEX ALGORITHM [J].
BERRIDGE, JC .
JOURNAL OF CHROMATOGRAPHY, 1982, 244 (01) :1-14
[4]   NEW PERSPECTIVES IN MICELLAR LIQUID-CHROMATOGRAPHY [J].
BORGERDING, MF ;
WILLIAMS, RL ;
HINZE, WL ;
QUINA, FH .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1989, 12 (08) :1367-1406
[5]   SIMULTANEOUS-OPTIMIZATION OF SEVERAL CHROMATOGRAPHIC PERFORMANCE GOALS USING DERRINGER DESIRABILITY FUNCTION [J].
BOURGUIGNON, B ;
MASSART, DL .
JOURNAL OF CHROMATOGRAPHY, 1991, 586 (01) :11-20
[6]   Optimisation of chromatographic separations by use of a chromatographic response function, empirical modelling and multivariate analysis [J].
Bylund, D ;
Bergens, A ;
Jacobsson, SP .
CHROMATOGRAPHIA, 1997, 44 (1-2) :74-80
[7]   COMPARISON OF OPTIMIZATION METHODS IN REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING MIXTURE DESIGNS AND MULTICRITERIA DECISION-MAKING [J].
COENEGRACHT, PMJ ;
SMILDE, AK ;
METTING, HJ ;
DOORNBOS, DA .
JOURNAL OF CHROMATOGRAPHY, 1989, 485 :195-217
[8]   COMPARATIVE MOLECULAR-FIELD ANALYSIS (COMFA) .1. EFFECT OF SHAPE ON BINDING OF STEROIDS TO CARRIER PROTEINS [J].
CRAMER, RD ;
PATTERSON, DE ;
BUNCE, JD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (18) :5959-5967
[9]  
DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968
[10]   Chemometrics approach to the optimization of ion chromatographic analysis of transition metal cations for routine work [J].
Divjak, B ;
Moder, M ;
Zupan, J .
ANALYTICA CHIMICA ACTA, 1998, 358 (03) :305-315