Immunosensor; Point of care; Lab on a chip; Reusable; Continuous monitoring; SURFACE-PLASMON RESONANCE; LABELESS IMMUNOSENSOR ASSAY; QUARTZ-CRYSTAL MICROBALANCE; LINKED-IMMUNOSORBENT-ASSAY; OPTICAL-FIBER IMMUNOSENSOR; STROKE MARKER PROTEIN; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; ALPHA-FETOPROTEIN; CARBON NANOTUBES;
D O I
10.1016/j.bios.2011.10.023
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This review details recent advances in the fields of immunosensors and closely related immunoassays in the past decade, together with a discussion of possible future trends. Immunosensors can be classified by the way in which they transduce the signal produced upon the formation of an antibody antigen complex. Recent advancements to these methods of detection and transduction are discussed in detail, with particular focus on electrochemical, optical, piezoelectric and magnetic based sensors. The varying applications of these sensors are also discussed. Some of the most significant advances include development of immunosensors for the continuous monitoring of analytes, point of care (PoC) devices, with lower unit costs, automation, reusability and ease of use. Immunosensor technology has advanced at a prolific rate since its conception and has grown into a diverse area of ongoing research. (C) 2012 Published by Elsevier B.V.
引用
收藏
页码:12 / 24
页数:13
相关论文
共 159 条
[1]   Surface plasmon resonance-based trace detection of small molecules by competitive and signal enhancement immunoreaction [J].
Aizawa, Hidenobu ;
Tozuka, Mitsuhiro ;
Kurosawa, Shigeru ;
Kobayashi, Koichi ;
Reddy, Subrayal M. ;
Higuchi, Masahiro .
ANALYTICA CHIMICA ACTA, 2007, 591 (02) :191-194
[2]   Market analysis of biosensors for food safety [J].
Alocilja, EC ;
Radke, SM .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :841-846
[3]   TNT detection using multiplexed liquid array displacement immunoassays [J].
Anderson, GP ;
Moreira, SC ;
Charles, PT ;
Medintz, IL ;
Goldman, ER ;
Zeinali, M ;
Taitt, CR .
ANALYTICAL CHEMISTRY, 2006, 78 (07) :2279-2285
[4]   Screen-printed electrodes as impedimetric immunosensors for the detection of anti-transglutaminase antibodies in human sera [J].
Balkenhohl, T. ;
Lisdat, F. .
ANALYTICA CHIMICA ACTA, 2007, 597 (01) :50-57
[5]   Labeless immunosensor assay for prostate specific antigen with picogram per milliliter limits of detection based upon an ac impedance protocol [J].
Barton, Andrew C. ;
Davis, Frank ;
Higson, Seamus P. J. .
ANALYTICAL CHEMISTRY, 2008, 80 (16) :6198-6205
[6]   LABELESS IMMUNOSENSOR ASSAY FOR THE STROKE MARKER PROTEIN S-100[β] BASED UPON AN AC IMPEDANCE PROTOCOL [J].
Barton, Andrew C. ;
Davis, Frank ;
Higson, Seamus P. J. .
ANALYTICAL LETTERS, 2010, 43 (14) :2160-2170
[7]   Labeless Immunosensor Assay for the Stroke Marker Protein Neuron Specific Enolase Based upon an Alternating Current Impedance Protocol [J].
Barton, Andrew C. ;
Davis, Frank ;
Higson, Seamus P. J. .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9411-9416
[8]   Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications [J].
Barton, Andrew C. ;
Collyer, Stuart D. ;
Davis, Frank ;
Garifallou, Goulielmos-Zois ;
Tsekenis, Georgios ;
Tully, Elizabeth ;
O'Kennedy, Richard ;
Gibson, Tim ;
Millner, Paul A. ;
Higson, Seamus P. J. .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (05) :1090-1095
[9]   DIRECT DETECTION OF IMMUNOSPECIES BY CAPACITANCE MEASUREMENTS [J].
BATAILLARD, P ;
GARDIES, F ;
JAFFREZICRENAULT, N ;
MARTELET, C ;
COLIN, B ;
MANDRAND, B .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2374-2379
[10]   THE DEVELOPMENT AND APPLICATION OF FET-BASED BIOSENSORS [J].
BERGVELD, P .
BIOSENSORS, 1986, 2 (01) :15-33