Labeless AC impedimetric antibody-based sensors with pg ml-1 sensitivities for point-of-care biomedical applications

被引:38
作者
Barton, Andrew C. [1 ]
Collyer, Stuart D. [1 ]
Davis, Frank [1 ]
Garifallou, Goulielmos-Zois [1 ]
Tsekenis, Georgios [1 ]
Tully, Elizabeth [2 ]
O'Kennedy, Richard [2 ]
Gibson, Tim [3 ]
Millner, Paul A. [3 ]
Higson, Seamus P. J. [1 ]
机构
[1] Cranfield Univ, Silsoe MK45 4DT, Beds, England
[2] Dublin City Univ, Sch Biotechnol, Dublin 9, Ireland
[3] Univ Leeds, Res Inst Membrane & Syst Biol, Biosensors & Bioelect Grp, Leeds LS2 9JT, W Yorkshire, England
关键词
AC impedance; Immunosensor; Polyaniline; Microelectrode; BSA; Digoxin; FABRICATED MICROELECTRODE ARRAYS; IMMUNOSENSOR ASSAY; BIOSENSORS;
D O I
10.1016/j.bios.2008.06.001
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper describes the development and characterisation of labeless immunosensors for (a) the cardiac drug digoxin and (b) bovine serum albumin (BSA). Commercial screen-printed carbon electrodes were used as the basis for the sensors. Two methods were used to immobilise antibodies at the electrode surface. Aniline was electropolymerised onto these electrodes to form a thin planar film of conductive polyaniline; the polyaniline film was then utilised as a substrate to immobilise biotinylated anti-digoxin using a classical avidin-biotin affinity approach. As an alternative approach, poly(1,2-diaminobenzene) was electrodeposited onto the carbon electrodes and this modified surface was then sonochemically ablated to form an array of micropores. A second electropolymerisation step was then used to co-deposit conductive polyaniline along with antibodies for BSA within these pores to produce a microarray of polyaniline protrusions with diameters of several mu m, containing entrapped anti-BSA. The resulting antibody grafted electrodes were interrogated using an AC impedance protocol before and following exposure to digoxin or BSA solutions, along with control samples containing a non-specific IgG antibody. The impedance characteristics of both types of electrode were changed by increasing concentrations of antigen up to a saturation level. Calibration curves were obtained by subtraction of the non-specific response from the specific response, thereby eliminating the effects of non-specific adsorption of antigen. Both the use of microelectrode arrays and affinity binding protocols showed large enhancements in sensitivity over planar electrodes containing entrapped antibodies and gave similar sensitivities to our other published work using affinity-based planar electrodes. Detection limits were in the order of 0.1 ng ml(-1) for digoxin and 1.5 ng ml(-1) for BSA. (c) 2008 Published by Elsevier B.V.
引用
收藏
页码:1090 / 1095
页数:6
相关论文
共 26 条
[1]  
[Anonymous], 1987, ANALYST, V112, P199
[2]  
BARTON, 2007, THESIS CRANFIELD U
[3]   Sonochemically fabricated microelectrode arrays for biosensors offering widespread applicability: Part I [J].
Barton, AC ;
Collyer, SD ;
Davis, F ;
Gornall, DD ;
Law, KA ;
Lawrence, ECD ;
Mills, DW ;
Myler, S ;
Pritchard, JA ;
Thompson, M ;
Higson, SPJ .
BIOSENSORS & BIOELECTRONICS, 2004, 20 (02) :328-337
[4]   Comparison of random and oriented immobilisation of antibody fragments on mixed self-assembled monolayers [J].
Bonroy, Kristien ;
Frederix, Filip ;
Reekmans, Gunter ;
Dewolf, Ellen ;
De Palma, Randy ;
Borghs, Gustaaf ;
Declerck, Paul ;
Goddeeris, Bruno .
JOURNAL OF IMMUNOLOGICAL METHODS, 2006, 312 (1-2) :167-181
[5]   ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY [J].
CLARK, LC ;
LYONS, C .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) :29-&
[6]   Affinity biosensors based on electropolymerized films [J].
Cosnier, S .
ELECTROANALYSIS, 2005, 17 (19) :1701-1715
[7]  
Davis F, 2007, CHIM OGGI, V25, P28
[8]   Recent advances in electrochemical enzyme immunoassays [J].
Díaz-González, M ;
González-García, MB ;
Costa-García, A .
ELECTROANALYSIS, 2005, 17 (21) :1901-1918
[9]  
GARIFALLOU, 2008, THESIS CRANFIELD U
[10]   Labeless immunosensor assay for fluoroquinolone antibiotics based upon an AC impedance protocol [J].
Garifallou, G.-Z. ;
Tsekenis, G. ;
Davis, F. ;
Higson, S. P. J. ;
Millner, P. A. ;
Pinacho, D. G. ;
Sanchez-Baeza, F. ;
Marco, M.-P. ;
Gibson, T. D. .
ANALYTICAL LETTERS, 2007, 40 (07) :1412-1422